Login
Register
Complete Your Profile
Change Password
Request a Password Reset
Download Documents
Download Documents
Get Help to Participate in This Tender
Change Password
For better security, update the account password.
The INDIAN ARMY has issued a Tender notice for the procurement of a M and L for Cable in Trenches or Passing through Pipe Xlpe Insulated Heavy Duty G Lt Cable for 1100, Qty: 868 in the India.The project location is Bardhaman, West Bengal, India. This Tender notice was published on 11 Nov 2026 and is scheduled to close on 21 Nov 2026, with an estimated Tender value of Refer Document. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 152351147, while the tender notice number is GEM/2026/B/8228328 and Register on the platform.
Purchaser contact is for registered users
Login to see details| # | Title | Description | Qty | Unit | Delivery (Days) |
|---|---|---|---|---|---|
| 1 | M and L for cable in trenches or passing through pipe XLPE insulated heavy duty g LT cable for 1100 volts grade cross sectional area 240 sqmm 3.5 core | M and L for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 240 sqmm 3.5 core | 125 | RM | 120 |
| 2 | M and L for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised LT cable with for 1100 volts grade cross sectional area 120 sqmm 3.5 core | M and L for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 120 sqmm 3.5 core | 300 | RM | 120 |
| 3 | Excavating in Trenches not exc 1.50 mtr wide and not exc 1.50 mtr in depth getting out in Soft or Loose Soil | Excavating in Trenches not exc 1.50 mtr wide and not exc 1.50 mtr in depth getting out in Soft or Loose Soil | 90 | CUM | 120 |
| 4 | Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc 250mm in Soft or Loose Soil | Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc 250mm in Soft or Loose Soil | 49 | CUM | 120 |
| 5 | Removing excavated Materials Soils not exc 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil | Removing excavated Materials Soils not exc 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil | 41 | CUM | 120 |
| 6 | M and L Sand Cushioning dry in Trenches for protection of UG Cables of 230mm Spread thickness and upto 180mm thickness complete | M and L Sand Cushioning dry in Trenches for protection of UG Cables of 230mm Spread thickness and consolidated upto 180mm thickness complete | 32 | CUM | 120 |
| 7 | M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable | M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable | 4 | Per 1000 Nos | 120 |
| 8 | S and F Galvanised Iron Pipe 80mm Bore dia Light Grade for protection of UG Cable laid in Floors or with Mild Steel Clamps Nuts Bolts etc | S and F Galvanised Iron Pipe 80mm Bore dia Light Grade for protection of UG Cable laid in Floors or Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts etc | 20 | RM | 120 |
| 9 | M and L for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia under Road or Foot Path not exc 10.00 mtr in a Single Length | M and L for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia under Road or Foot Path not exc 10.00 mtr in a Single Length | 20 | RM | 120 |
| 10 | Supply commissioning a CPRI approved Seven tank treatment powder coated factory made LT Panelside canopy headed Cable alley at both sides size MS angle | Supply commissioning and testing Outdoor type LT Distribution Panel Double door type weather proof CPRI approved Seven tank treatment powder coated factory made LT Panel board totally enclosed dust and vermin proof openable from front and back side canopy headed Cable alley at both sides connected with suitable size MS angle iron frame for main distribution Panel | 1 | Each | 120 |
| 11 | Supply commissioning and testing Outdoor type LT Distribution Panel Double door type weather proof CPRI approved Seven tank treatment powder coated | Supply commissioning and testing Outdoor type LT Distribution Panel Double door type weather proof CPRI approved Seven tank treatment powder coated factory made LT Panel board | 2 | Each | 120 |
| 12 | M and L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm less than 2.25 mtrs deep below ot less than 1.5 mtrs below normal ground level | M and L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground earth pit not less than 2.25 mtrs deep below ground level with top edge of the plate not less than 1.5 mtrs below normal ground level | 8 | Each set | 120 |
| 13 | S and F 4 Pole 630 Amp Changeover Switch with enclosure suitable for 415 V AC 3 phase 4 wire 50 Hz system for and DG set | S and F 4 Pole 630 Amp Changeover Switch with enclosure suitable for 415 V AC 3 phase 4 wire 50 Hz system for changeover between Main supply and DG set | 1 | Each | 120 |
| 14 | M and L for surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out complete | M and L for surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out complete | 60 | Sqm | 120 |
| 15 | M and L 150 mm thick soiling with broken boulders or quarried stone interstices filled suface formed and rolled and consolidated to required gradient and camber | M and L 150 mm thick soiling with broken boulders or quarried stone interstices filled suface formed and rolled and consolidated to required gradient and camber | 60 | Sqm | 120 |
| 16 | M and L for moorum or red bajri filling in floors or pavings laid in layers n exc 15 cm thick spread levelled and rammed including watering complete | M and L for moorum or red bajri filling in floors or pavings laid in layers n exc 15 cm thick spread levelled and rammed including watering complete | 15 | CUM | 120 |
| 17 | M and L for PCC 1 4 8 type D 2 40mm graded aggregate in foundations filling and mass concrete | M and L for PCC 1 4 8 type D 2 40mm graded aggregate in foundations filling and mass concrete | 29 | CUM | 120 |
| 18 | M and L for PCC 1 2 4 type B1 using 20mm grade aggregate as in coping for pole inclduing form work and finishing the surfaces even and smooth | M and L for PCC 1 2 4 type B1 using 20mm grade aggregate as in coping for pole inclduing form work and finishing the surfaces even and smooth | 7 | CUM | 120 |