Expired Tender India NCB TOT Ref. 152004721

M and L for Cable in Trenches or Passing through Tender - 152004721

Tender notice from India, published on 05 Nov 2026.

Executive Summary

The INDIAN ARMY has issued a Tender notice for the procurement of a M and L for Cable in Trenches or Passing through Pipe Xlpe Insulated Heavy Duty for 1100 Volts Grad, Qty: 3626 in the India.The project location is Bardhaman, West Bengal, India. This Tender notice was published on 05 Nov 2026 and is scheduled to close on 14 Nov 2026, with an estimated Tender value of Refer Document. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 152004721, while the tender notice number is GEM/2026/B/8228539 and Register on the platform.

Key facts

Summary
M and L for Cable in Trenches or Passing through Pipe Xlpe Insulated Heavy Duty for 1100 Volts Grad, Qty: 3626
TOT Ref. No.
152004721
Document Ref. No.
GEM/2026/B/8228539
City
Bardhaman
State
West Bengal
Notice type
Tender
Competition
NCB
Publication date
05 Nov 2026
Bid deadline
14 Nov 2026
EMD
Refer Document
Tender value
Refer Document
Purchaser ownership
Public
Procurement Type
Works
Financier
Self Financed

CPV classification

Purchaser details

Purchaser contact is for registered users

Login to see details

Tender details

M and L for cable in trenches or passing through pipe XLPE insulated heavy duty for 1100 volts grade cross sectional area 25 sqmm 3.5 core including cable gland and lugs, M and L for cable in trenches or passing through pipe XLPE insulated LT cable with for 1100 volts grade cross sectional area 70 sqmm 3.5 core including cable gland, M and L for cable in trenches or passing through pipe XLPE insulated heavy duty LT cable with for 1100 volts grade cross sectional area 95 sqmm 3.5 core, M and L for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or for 1100 volts grade cross sectional area 240 sqmm 3.5 core, Excavating in Trenches not exc 1.50 mtr wide and not exc 1.50 mtr in depth getting out in Soft or Loose Soil, Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc 250mm in Soft or Loose Soil, Removing excavated Materials not exc 50.00 mtr and depositing where directed at a level not exc 1.50 mtr above the Starting Point in Soil, M and L Sand Cushioning in Trenches for protection of UG Cables of 230mm Spread thickness and consolidated upto 180mm thickness complete, M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable, S and F Galvanised Iron Pipe 80mm Bore dia Light Grade for protection of UG Cable laid in Floors or Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts, S and F Galvanised Iron Pipe...

PVC Insulated Unsheathed Cable with Flexible Conductor
BOQ Desc:

M and L for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 25 sqmm 3.5 core including cable gland and lugs

S and F HDPE DWC of Diameter 40 mm including disconnection and connection of cable near panel or OH for pipe fixing including joints

M and L for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia under Road Foot Path not exc 10.00 mtr in a Single Length

M and L for earthing complete with MS galvanized plate of size 60cm 60cm 6mm as 2.25 mtrs deep below not less than 1.5 mtrs below normal ground level, M and L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground earth pit not less than 2.25 mtrs deep below ground level with top edge of the plate not less than 1.5 mtrs below normal ground level

Supply and Fixing sheet moulding compound junction box IP 66 weather proof for outdoor installation of size 205 255 112 with knockouts for cable 2 Nos 4 10 to 25 Sqmm, Supply and Fixing sheet moulding compound junction box IP 66 weather proof for outdoor installation of size 205 x 255 x 112 with knockouts for cable entry suitable for terminating 2 Nos 4 x 10 to 25 Sqmm UG cable including MS clamp with nut and bolt and cable glandes 2 Nos and four way terminal

Supply and Fixing Submain wiring with five runs of 6 sqmm single core multi stranded FRLS unsheathed PVC copper conductor cable 1100 Volts as per colour code drawn in casing capping including all accessories as required and connecting to Existing main switch board and testing on completion including dismantling old unserviceable submain wiring complete.

Supply commissioning and testing LT Distribution Panel CPRI approved Seven tank treatment e LT PaneL CRCA sheet 315mm thick sheet, Supply commissioning and testing Outdoor type LT Distribution Panel Double door type weather proof CPRI approved Seven tank treatment powder coated factory made LT Panel board totally enclosed dust and vermin proof openable from front and back side canopy headed Cable alley at both sides, connected with suitable size MS angle iron frame for main distribution Panel fabricated with CRCA sheet 3.15mm thick sheet

Supply and Fix sheet metal enclosure for TPN DB 4 way double door factory made powder coated including bus bar and earth link connector fixed in wall or Panel complete

Supply and Fix in repair MCB 63 Amps TPN braking capacity 10KA C series all as specified and directed

Supply and Fix in repair MCB 6 to 32 Amps SP braking capacity 10KA C series all as specified and directed
Quantity Required: 3626

Start Date: 04-11-2026 8:49 PM

End Date: 14-11-2026 9:00 PM

Relevant Categories: PVC Insulated Unsheathed Cable with Flexible Conductor

GeMARPTS Searched: Electrical Cable Lugs
Tender ID: GEM/2026/B/8228539

Documents

Tender Notice
Login to view
Bid_Document_10113600.pdf
Login to view
Specification_Document.pdf
Login to view
BOQ_Document.csv
Login to view

Bill of Quantities (BOQ)

# Title Description Qty Unit Delivery (Days)
1 M and L for cable in trenches or passing through pipe XLPE insulated heavy duty for 1100 volts grade cross sectional area 25 sqmm 3.5 core including cable gland and lugs M and L for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 25 sqmm 3.5 core including cable gland and lugs 510 RM 100
2 M and L for cable in trenches or passing through pipe XLPE insulated LT cable with for 1100 volts grade cross sectional area 70 sqmm 3.5 core including cable gland M and L for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 70 sqmm 3.5 core including cable gland 700 RM 100
3 M and L for cable in trenches or passing through pipe XLPE insulated heavy duty LT cable with for 1100 volts grade cross sectional area 95 sqmm 3.5 core M and L for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 95 sqmm 3.5 core 400 RM 100
4 M and L for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or for 1100 volts grade cross sectional area 240 sqmm 3.5 core M and L for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 240 sqmm 3.5 core 100 RM 100
5 Excavating in Trenches not exc 1.50 mtr wide and not exc 1.50 mtr in depth getting out in Soft or Loose Soil Excavating in Trenches not exc 1.50 mtr wide and not exc 1.50 mtr in depth getting out in Soft or Loose Soil 365 CUM 100
6 Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc 250mm in Soft or Loose Soil Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc 250mm in Soft or Loose Soil 262 CUM 100
7 Removing excavated Materials not exc 50.00 mtr and depositing where directed at a level not exc 1.50 mtr above the Starting Point in Soil Removing excavated Materials not exc 50.00 mtr and depositing where directed at a level not exc 1.50 mtr above the Starting Point in Soil 103 CUM 100
8 M and L Sand Cushioning in Trenches for protection of UG Cables of 230mm Spread thickness and consolidated upto 180mm thickness complete M and L Sand Cushioning in Trenches for protection of UG Cables of 230mm Spread thickness and consolidated upto 180mm thickness complete 92 CUM 100
9 M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable M and L for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable 11 Per 1000 Nos 100
10 S and F Galvanised Iron Pipe 80mm Bore dia Light Grade for protection of UG Cable laid in Floors or Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts S and F Galvanised Iron Pipe 80mm Bore dia Light Grade for protection of UG Cable laid in Floors or Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts 30 RM 100
11 S and F Galvanised Iron Pipe 50mm Bore Light Grade for protection of UG Cable laid in Floors Crossing fixing to Pole with Mild Steel Clamps, Nuts, Bolts S and F Galvanised Iron Pipe 50mm Bore Light Grade for protection of UG Cable laid in Floors Crossing fixing to Pole with Mild Steel Clamps, Nuts, Bolts 30 RM 100
12 S and F HDPE DWC of Diameter 40 mm including disconnection and connection of cable near panel or OH for pipe fixing including joints S and F HDPE DWC of Diameter 40 mm including disconnection and connection of cable near panel or OH for pipe fixing including joints 485 RM 100
13 S and F HDPE DWC of Diameter 90 mm including disconnection and connection of cable near panel or OH for pipe fixing including joints S and F HDPE DWC of Diameter 90 mm including disconnection and connection of cable near panel or OH for pipe fixing including joints 20 RM 100
14 M and L for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia under Road Foot Path not exc 10.00 mtr in a Single Length M and L for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia under Road Foot Path not exc 10.00 mtr in a Single Length 30 RM 100
15 M and L for earthing complete with MS galvanized plate of size 60cm 60cm 6mm as 2.25 mtrs deep below not less than 1.5 mtrs below normal ground level M and L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground earth pit not less than 2.25 mtrs deep below ground level with top edge of the plate not less than 1.5 mtrs below normal ground level 22 Each Set 100
16 Supply and Fixing sheet moulding compound junction box IP 66 weather proof for outdoor installation of size 205 255 112 with knockouts for cable 2 Nos 4 10 to 25 Sqmm Supply and Fixing sheet moulding compound junction box IP 66 weather proof for outdoor installation of size 205 x 255 x 112 with knockouts for cable entry suitable for terminating 2 Nos 4 x 10 to 25 Sqmm UG cable including MS clamp with nut and bolt and cable glandes 2 Nos and four way terminal 50 Each 100
17 Supply and Fixing Submain wiring with five runs of 6 sqmm single core multi stranded FRLS unsheathed PVC copper conductor cable 1100 Volts as per colour code drawn in casing capping Supply and Fixing Submain wiring with five runs of 6 sqmm single core multi stranded FRLS unsheathed PVC copper conductor cable 1100 Volts as per colour code drawn in casing capping including all accessories as required and connecting to Existing main switch board and testing on completion including dismantling old unserviceable submain wiring complete. 50 RM 100
18 Supply commissioning and testing LT Distribution Panel CPRI approved Seven tank treatment e LT PaneL CRCA sheet 315mm thick sheet Supply commissioning and testing Outdoor type LT Distribution Panel Double door type weather proof CPRI approved Seven tank treatment powder coated factory made LT Panel board totally enclosed dust and vermin proof openable from front and back side canopy headed Cable alley at both sides, connected with suitable size MS angle iron frame for main distribution Panel fabricated with CRCA sheet 3.15mm thick sheet 1 Each 100
19 Supply commissioning and testing Outdoor type LT Distribution Panel Double door type weather proof CPRI approved Seven tank treatment Supply commissioning and testing Outdoor type LT Distribution Panel Double door type weather proof CPRI approved Seven tank treatment powder coated factory made LT Panel board totally enclosed dust and vermin proof openable from front and back side canopy headed 9 Each 100
20 Supply and Fix sheet metal enclosure for TPN DB 4 way double door factory made powder coated including Supply and Fix sheet metal enclosure for TPN DB 4 way double door factory made powder coated including bus bar and earth link connector fixed in wall or Panel complete 25 Each 100
21 Supply and Fix in repair MCB 63 Amps TPN braking capacity 10KA C series all as specified and directed Supply and Fix in repair MCB 63 Amps TPN braking capacity 10KA C series all as specified and directed 25 Each 100
22 Supply and Fix in repair MCB 6 to 32 Amps SP braking capacity 10KA C series all as specified and directed Supply and Fix in repair MCB 6 to 32 Amps SP braking capacity 10KA C series all as specified and directed 300 Each 100

Corresponding contract award notice

Similar tenders

India Public Procurement Intelligence

Frequently asked questions

The bid deadline for M and L for Cable in Trenches or Passing through Pipe Xlpe Insulated Heavy Duty for 1100 Volts Grad, Qty: 3626 was 14 Nov 2026. Bidding is closed.

This tender has been issued by INDIAN ARMY in India.

The tender value is not disclosed; please refer to the tender document. EMD / bid security details are provided in the tender document.

This tender is Self Financed

This is a Works procurement tender issued as a public sector opportunity in India.

The tender is classified under the following CPV code(s): 44321000 - Cable.

The tender notice and related documents are listed in the Documents section above. Select a document to view or download it. Please log in or register to access the documents. If you cannot find additional documents in the Documents section, please log in to your account and Send Document Request from your account section.

The TendersOnTime reference is 152004721. The purchaser document reference is GEM/2026/B/8228539.

See the Similar Tenders section on this page or browse other tenders from India.

This tender falls under Materials and Products in India. Suppliers in these sectors can track similar India tenders using CPV-based alerts.