Expired Tender India NCB TOT Ref. 152433528

M and L for Cable in Trenches or Passing through Tender - 152433528

Tender notice from India, published on 13 Nov 2026.

Executive Summary

The INDIAN ARMY has issued a Tender notice for the procurement of a M and L for Cable in Trenches or Passing through Pipe Xlpe Insulated 50 Sqmm 3.5 Core Etc., All as P, Qty: 3309 in the India.The project location is Bardhaman, West Bengal, India. This Tender notice was published on 13 Nov 2026 and is scheduled to close on 23 Nov 2026, with an estimated Tender value of Refer Document. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 152433528, while the tender notice number is GEM/2026/B/8256287 and Register on the platform.

Key facts

Summary
M and L for Cable in Trenches or Passing through Pipe Xlpe Insulated 50 Sqmm 3.5 Core Etc., All as P, Qty: 3309
TOT Ref. No.
152433528
Document Ref. No.
GEM/2026/B/8256287
City
Bardhaman
State
West Bengal
Notice type
Tender
Competition
NCB
Publication date
13 Nov 2026
Bid deadline
23 Nov 2026
EMD
Refer Document
Tender value
Refer Document
Purchaser ownership
Public
Financier
Self Financed

CPV classification

Purchaser details

Purchaser contact is for registered users

Login to see details

Tender details

M and L for cable in trenches or passing through pipe XLPE insulated 50 sqmm 3.5 core etc., All as per Item Ser No. 1 above but of size 70 Sqmm 3.5 Core., All as per Item Ser No. 1 above but of size 120 Sqmm 3.5 Core., Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr etc., Returning Filling in including Spreading Levelling Watering and Well etc., Removing excavated Materials Soils not exc. 50.00 mtr and depositing where etc., M and L Sand Cushioning dry in Trenches for protection of UG Cables below etc., M and L for fly ash bricks locally available laid dry width wise across the line of cable etc., S and F Galvanised Iron Pipe 80mm Bore dia Light Grade for protection of UG Cable etc., S and F Galvanised Iron Pipe 50mm Bore dia Light Grade for protection of UG Cable etc., S and F HDPE DWC Double Walled Corrugated of Diameter 40 mm etc., S and F HDPE DWC Double Walled Corrugated of Diameter 63 mm etc., M and L for Horizontal Boring for Passing Protection Pipe up to 80mm Bore etc., M and L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode etc., Supply commissioning and testing Outdoor type LT Distribution Panel Double door etc., Supply commissioning and testing Outdoor type LT Distribution Panel Double door type weather proof CPRI etc., Supply and Fix Metal cable route indicator of height 750 mm MS Flat of 40 mm etc., Insulation Tester (Q3)

Burnt Clay Fly Ash Building Bricks conforming to IS 13757
BOQ Desc:

ML for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 50 sqmm 3.5 core including cable gland and lugs including taking down old unserviceable cable complete all as specified and directed.

Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth getting out in Soft Loose Soil complete all as specified and as directed.

Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc. 250mm in SoftLoose Soil complete all as specified and as directed.

Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil complete all as specified and as directed.

ML Sand Cushioning dry in Trenches for protection of UG Cables below above and around the UG Cable laid in Trenches of 230mm Spread thickness and consolidated punned upto 180mm thickness complete all as specified and as directed. Note For the purpose of Payment Punned thickness of Sand Cushioning only shall be Measured and Paid.

ML for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed.

SF Galvanised Iron Pipe 80mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts etc. complete all as specified and as directed.

S F HDPE DWC Double Walled Corrugated of Diameter 40 mm with coupler including disconnection and connection of cable near panelOH for pipe fixing including joints complete all as directed.

ML for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia under Road Foot Path not exc. 10.00 mtr in a Single Length complete all as specified and as directed. Note Pipe to be measured separately.

ML for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground earth pit not less than 2.25 mtrs deep below ground level with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised iron strip 25x4mm as earthing lead by means of bolts nuts check nuts and washers of galvanised ironwelding or steel all as shown in electrical plate No 3 in SSR Part I of 2009 connected to earthing test point all as specified complete with excavation earth work PCC pit with 50mm thick RCC coverCI MS cover having suitable handle 10mm MS Rod 20mm dia GI medium grade watering pipe with GI funnel with wire mesh 40mm bore GI pipe medium grade ISI marked for protection of earth lead conductor and testing on completion complete all as specified and as directed by Engineer in Charge.

Supply commissioning and testing Outdoor type LT Distribution Panel Double door type weather proof CPRI approved Seven tank treatment powder coated factory made LT Panel board totally enclosed dust and vermin proof openable from front back side canopy headedCable alley at both sides connected with suitable size MS angle iron frame for main distribution Panel fabricated with CRCA sheet 315mm thick sheet incluing IP 54 protection installed on concrete base made of PCC 136 type C1 using 20mm graded aggregate including self locking arragement including taking down old unserviceable one BUS BAR CH...
Quantity Required: 3309

Start Date: 12-11-2026 7:20 PM

End Date: 23-11-2026 8:00 PM

Relevant Categories: Burnt Clay Fly Ash Building Bricks conforming to IS 13757

GeMARPTS Searched: Common Burnt Clay Building Bricks conforming to IS 1077
Tender ID: GEM/2026/B/8256287

Documents

Tender Notice
Login to view
Bid_Document_10145380.pdf
Login to view
Specification_Document.pdf
Login to view
BOQ_Document.csv
Login to view

Bill of Quantities (BOQ)

# Title Description Qty Unit Delivery (Days)
1 M and L for cable in trenches or passing through pipe XLPE insulated 50 sqmm 3.5 core etc. ML for cable in trenches or passing through pipe XLPE insulated heavy duty galvanised steel strip or wire armoured electric LT cable with stranded aluminium conductor for 1100 volts grade cross sectional area 50 sqmm 3.5 core including cable gland and lugs including taking down old unserviceable cable complete all as specified and directed. 500 RM 90
2 All as per Item Ser No. 1 above but of size 70 Sqmm 3.5 Core. All as per Item Ser No. 1 above but of size 70 Sqmm 3.5 Core. 800 RM 90
3 All as per Item Ser No. 1 above but of size 120 Sqmm 3.5 Core. All as per Item Ser No. 1 above but of size 120 Sqmm 3.5 Core. 720 RM 90
4 Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr etc. Excavating in Trenches not exc. 1.50 mtr wide and not exc. 1.50 mtr in depth getting out in Soft Loose Soil complete all as specified and as directed. 431 CUM 90
5 Returning Filling in including Spreading Levelling Watering and Well etc. Returning Filling in including Spreading Levelling Watering and Well Ramming in Layers not exc. 250mm in SoftLoose Soil complete all as specified and as directed. 233 CUM 90
6 Removing excavated Materials Soils not exc. 50.00 mtr and depositing where etc. Removing excavated Materials Soils not exc. 50.00 mtr and depositing where directed at a level not exc. 1.50 mtr above the Starting Point in Soil complete all as specified and as directed. 198 CUM 90
7 M and L Sand Cushioning dry in Trenches for protection of UG Cables below etc. ML Sand Cushioning dry in Trenches for protection of UG Cables below above and around the UG Cable laid in Trenches of 230mm Spread thickness and consolidated punned upto 180mm thickness complete all as specified and as directed. Note For the purpose of Payment Punned thickness of Sand Cushioning only shall be Measured and Paid. 155 CUM 90
8 M and L for fly ash bricks locally available laid dry width wise across the line of cable etc. ML for fly ash bricks locally available laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed. 19 Per 1000 Nos 90
9 S and F Galvanised Iron Pipe 80mm Bore dia Light Grade for protection of UG Cable etc. SF Galvanised Iron Pipe 80mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts etc. complete all as specified and as directed. 21 RM 90
10 S and F Galvanised Iron Pipe 50mm Bore dia Light Grade for protection of UG Cable etc. SF Galvanised Iron Pipe 50mm Bore dia Light Grade for protection of UG Cable laid in Floors Road Crossing fixing to Pole with Mild Steel Clamps Nuts Bolts etc. complete all as specified and as directed. 22 RM 90
11 S and F HDPE DWC Double Walled Corrugated of Diameter 40 mm etc. S F HDPE DWC Double Walled Corrugated of Diameter 40 mm with coupler including disconnection and connection of cable near panelOH for pipe fixing including joints complete all as directed. 30 RM 90
12 S and F HDPE DWC Double Walled Corrugated of Diameter 63 mm etc. S F HDPE DWC Double Walled Corrugated of Diameter 63 mm with including disconnection and connection of cable near panelOH for pipe fixing including joints complete all as directed. 30 RM 90
13 M and L for Horizontal Boring for Passing Protection Pipe up to 80mm Bore etc. ML for Horizontal Boring for Passing Protection Pipe up to 80mm Bore dia under Road Foot Path not exc. 10.00 mtr in a Single Length complete all as specified and as directed. Note Pipe to be measured separately. 30 RM 90
14 M and L for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode etc. ML for earthing complete with MS galvanized plate of size 60cmx60cmx6mm as earth electrode buried directly in ground earth pit not less than 2.25 mtrs deep below ground level with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised iron strip 25x4mm as earthing lead by means of bolts nuts check nuts and washers of galvanised ironwelding or steel all as shown in electrical plate No 3 in SSR Part I of 2009 connected to earthing test point all as specified complete with excavation earth work PCC pit with 50mm thick RCC coverCI MS cover having suitable handle 10mm MS Rod 20mm dia GI medium grade watering pipe with GI funnel with wire mesh 40mm bore GI pipe medium grade ISI marked for protection of earth lead conductor and testing on completion complete all as specified and as directed by Engineer in Charge. 12 Each Set 90
15 Supply commissioning and testing Outdoor type LT Distribution Panel Double door etc. Supply commissioning and testing Outdoor type LT Distribution Panel Double door type weather proof CPRI approved Seven tank treatment powder coated factory made LT Panel board totally enclosed dust and vermin proof openable from front back side canopy headedCable alley at both sides connected with suitable size MS angle iron frame for main distribution Panel fabricated with CRCA sheet 315mm thick sheet incluing IP 54 protection installed on concrete base made of PCC 136 type C1 using 20mm graded aggregate including self locking arragement including taking down old unserviceable one BUS BAR CHAMBER a Sheet steel bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity TPN solid aluminium bus bars rated 600 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings The bars shall be colour coded at required intervals for identification SET OF 4 1 No INCOMER a MCCB 400 Amps 415 volt 36 KA Breaking capacity 4 pole duly connected to bus bar 01 Nos OUTGOING FEEDERS a MCCB 200 Amps 415 volt 36 KA Breaking capacity 4 pole duly connected to bus bar 02 Nos b MCCB 100 Amps 415 volt 18 KA Breaking capacity 4 pole duly connected to bus bar 02 Nos c MCCB 63 Amps 415 volt 18 KA Breaking capacity 4 pole duly connected to bus bar 02 Nos INDICATING DEVICES a LED Indicating lamps for Main Supply indicating R Y B Set of 3 b Three Phase Ammeter3 Row Cl 10 Make Elmeasure Cat part No SL1330S10000 or equivalent 1 No c Current Transformer having Ratio 1255 SET OF 3 d Three Phase Voltmeter3 Row Cl 10 Cat Make Elmeasure Part No SL1340S10000 or equivalent 1 No 1 Each 90
16 Supply commissioning and testing Outdoor type LT Distribution Panel Double door etc. Supply commissioning and testing Outdoor type LT Distribution Panel Double door type weather proof CPRI approved Seven tank treatment powder coated factory made LT Panel board totally enclosed dust and vermin proof openable from front back side canopy headedCable alley at both sides connected with suitable size MS angle iron frame for main distribution Panel fabricated with CRCA sheet 315mm thick sheet incluing IP 54 protection installed on concrete base made of PCC 136 type C1 using 20mm graded aggregate including self locking arragement including taking down old unserviceable one BUS BAR CHAMBER aSheet steel bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity TPN solid aluminium bus bars rated 300 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings The bars shall be colour coded at required intervals for identification SET OF 4 1 No INCOMER a MCCB 200 Amps 415 volt 36 KA Breaking capacity 4 pole duly connected to bus bar 01 Nos OUTGOING FEEDERS a MCCB 100 Amps 415 volt 18 KA Breaking capacity 4 pole duly connected to bus bar 04 Nos a MCCB 63 Amps 415 volt 18 KA Breaking capacity 4 pole duly connected to bus bar 02 Nos INDICATING DEVICES a LED Indicating lamps for Main Supply indicating R Y B Set of 3 b Three Phase Ammeter3 Row Cl 10 Make Elmeasure Cat part No SL1330S10000 or equivalent 1 No c Current Transformer having Ratio 1255 SET OF 3 d Three Phase Voltmeter3 Row Cl 10 Cat Make Elmeasure Part No SL1340S10000 or equivalent 1 No 2 Each 90
17 Supply commissioning and testing Outdoor type LT Distribution Panel Double door type weather proof CPRI etc. Supply commissioning and testing Outdoor type LT Distribution Panel Double door type weather proof CPRI approved Seven tank treatment powder coated factory made LT Panel board totally enclosed dust and vermin proof openable from front back side canopy headedCable alley at both sides connected with suitable size MS angle iron frame for main distribution Panel fabricated with CRCA sheet 315mm thick sheet incluing IP 54 protection installed on concrete base made of PCC 136 type C1 using 20mm graded aggregate including self locking arragement BUS BAR CHAMBER aSheet steel bus bar chamber having front hinged covers with a set of electrolytic grade high conductivity TPN solid aluminium bus bars rated 150 Amps supported at required intervals sleeved with heat shrinkable PVC sleevings The bars shall be colour coded at required intervals for identification SET OF 4 1 No INCOMER a MCCB 100 Amps 415 volt 18 KA Breaking capacity 4 pole duly connected to bus bar 01 Nos OUTGOING FEEDERS a MCCB 63 Amps 415 volt 18 KA Breaking capacity 4 pole duly connected to bus bar 02 Nos a MCCB 40 Amps 415 volt 18 KA Breaking capacity 4 pole duly connected to bus bar 02 Nos INDICATING DEVICES a LED Indicating lamps for Main Supply indicating R Y B Set of 3 b Three Phase Ammeter3 Row Cl 10 Make Elmeasure Cat part No SL1330S10000 or equivalent 1 No c Current Transformer having Ratio 1255 SET OF 3 d Three Phase Voltmeter3 Row Cl 10 Cat Make Elmeasure Part No SL1340S10000 or equivalent 1 No 3 Each 90
18 Supply and Fix Metal cable route indicator of height 750 mm MS Flat of 40 mm etc. Supply and Fix Metal cable route indicator of height 750 mm MS Flat of 40 mm x 4 mm with Circular 100 mm diameter MS Sheet of minimun thickness 3 mm duly engraved LT CABLE including Aluminium paint over it and to be fixed 150 mm below ground level with PCC 1 3 6 40 mm aggregate of size 250x250x300 mm all as directed by Engr in Charge. 101 Each 90

Similar tenders

India Public Procurement Intelligence

Frequently asked questions

The bid deadline for M and L for Cable in Trenches or Passing through Pipe Xlpe Insulated 50 Sqmm 3.5 Core Etc., All as P, Qty: 3309 was 23 Nov 2026. Bidding is closed.

This tender has been issued by INDIAN ARMY in India.

The tender value is not disclosed; please refer to the tender document. EMD / bid security details are provided in the tender document.

This tender is Self Financed

The tender is classified under the following CPV code(s): 31300000 - Insulated wire and cable.

The tender notice and related documents are listed in the Documents section above. Select a document to view or download it. Please log in or register to access the documents. If you cannot find additional documents in the Documents section, please log in to your account and Send Document Request from your account section.

The TendersOnTime reference is 152433528. The purchaser document reference is GEM/2026/B/8256287.

See the Similar Tenders section on this page or browse other tenders from India.

This tender falls under Technology and Equipment in India. Suppliers in these sectors can track similar India tenders using CPV-based alerts.