Login
Register
Complete Your Profile
Change Password
Request a Password Reset
Download Documents
Download Documents
Get Help to Participate in This Tender
Change Password
For better security, update the account password.
The MINISTRY OF HEALTH AND FAMILY WELFARE has issued a Tender notice for the procurement of a Ionic rays safety pad, Radiation protective Lead aprons with accessories, Qty: 10000 in the India.The project location is South West Delhi, Delhi (NCT), India. This Tender notice was published on 27 Nov 2026 and is scheduled to close on 18 Dec 2026, with an estimated Tender value of 33885000. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 153128130 and Register on the platform.
Purchaser contact is for registered users
Login to see detailsTender details are for registered users
Login to see details| # | Title | Description | Qty | Unit | Delivery (Days) |
|---|---|---|---|---|---|
| 1 | 1 Femoral entry angiogragphy shield | Drape or shield should be absorbable material non vinyl non rubber and 100 Percent Lead free Must be single or bilayer technology sterilized chemical gas radiation and fit for safety during Femoral procedures Quoted model code should have latest twelve months old BARC test certificate Should have valid ISO 13485 2016 from notified body CE certified as per latest directive EU 2017 745 from notified body relevant MD license from CDSCO with status mentioned as sterilized shield drape Manufacturer supplier should have ICMED certification LE should not be greater than 0 point130mmPb attenuation size should be 450 into 395mm or less either side to have effective shadow zone and weight should be maximum of 400 gm Mandatory Requirements with document proof Must have clinically proven efficacy in reducing operators scatter exposure from 70 to 95 percent and must have minimum two clinical publications in pub med indexed journal Material composite construction ensuring zero secondary fluorescent backscattering to the patient supported by Study proof Core Material must be free from environmental hazards and supported by published study and environmental safety document Disposal process IFU declaration should certify that drapes can be disposed like regular drapes used in cath lab | 500 | pieces | 90 |
| 2 | 2 Femoral entry angiogragphy shield | Drape or shield should be absorbable material non vinyl non rubber and 100 Percent Lead free Must be single or bilayer technology sterilized chemical gas radiation and fit for safety during Femoral procedures Quoted model code should have latest twelve months old BARC test certificate Should have valid ISO 13485 2016 from notified body CE certified as per latest directive EU 2017 745 from notified body relevant MD license from CDSCO with status mentioned as sterilized shield drape Manufacturer supplier should have ICMED certification LE should not be greater than 0 point130mmPb attenuation size should be 450 into 395mm or less either side to have effective shadow zone and weight should be maximum of 400 gm Mandatory Requirements with document proof Must have clinically proven efficacy in reducing operators scatter exposure from 70 to 95 percent and must have minimum two clinical publications in pub med indexed journal Material composite construction ensuring zero secondary fluorescent backscattering to the patient supported by Study proof Core Material must be free from environmental hazards and supported by published study and environmental safety document Disposal process IFU declaration should certify that drapes can be disposed like regular drapes used in cath lab | 500 | pieces | 180 |
| 3 | 3 Fenestrated Radial entry shield | Drape or shield should be absorbable material non vinyl non rubber and 100 percent Lead free Must be single or bilayer technology sterilized chemical gas radiation and fit for safety during EP Device Procedures Quoted model or code should have latest twelve months Old BARC test certificate Should have valid IS0 13485 2016 from notified body CE certified as per latest 500 directive EU 2017 745 from notified body relevant MD license from CDSCO with status mentioned as sterilized shield Manufacturer or supplier should have ICMED certification LE should not be greater than 0point 130mmPb and Drape attenuation size should be less than 430 into 350mm to have effective shadow zone and weight should be maximum of 400 Mandatory Requirements with document proof Must have clinically proven efficacy in reducing operator scatter exposure from 70 to 95percent and must have minimum two clinical publications in pub med indexed journal Material composite construction ensuring zero secondary fluorescent backscattering to the patient supported by Study proof Core Material must be free from environmental hazards and supported by peer reviewed published studies and environmental safety document Disposal process IFU declaration should certify that drapes can be disposed like regular drapes used in cath lab | 2000 | pieces | 90 |
| 4 | 4 Fenestrated Radial entry shield | Drape or shield should be absorbable material non vinyl non rubber and 100 percent Lead free Must be single or bilayer technology sterilized chemical gas radiation and fit for safety during EP Device Procedures Quoted model or code should have latest twelve months Old BARC test certificate Should have valid IS0 13485 2016 from notified body CE certified as per latest 500 directive EU 2017 745 from notified body relevant MD license from CDSCO with status mentioned as sterilized shield Manufacturer or supplier should have ICMED certification LE should not be greater than 0point 130mmPb and Drape attenuation size should be less than 430 into 350mm to have effective shadow zone and weight should be maximum of 400 Mandatory Requirements with document proof Must have clinically proven efficacy in reducing operator scatter exposure from 70 to 95percent and must have minimum two clinical publications in pub med indexed journal Material composite construction ensuring zero secondary fluorescent backscattering to the patient supported by Study proof Core Material must be free from environmental hazards and supported by peer reviewed published studies and environmental safety document Disposal process IFU declaration should certify that drapes can be disposed like regular drapes used in cath lab | 1500 | pieces | 180 |
| 5 | 5 EP subclavian shield | Drape or shield should be absorbable material non vinyl non rubber and 100 percent Lead free Must be single or bilayer technology sterilized chemical gas radiation and fit for safety during EP Device Procedures Quoted model code should have latest twelve months Old BARC test certificate Should have valid IS0 13485 2016 from notified body CE certified as per latest 500 directive EU 2017 745 from notified body relevant MD license from CDSCO with status mentioned as sterilized shield Manufacturer supplier should have ICMED certification LE should not be greater than 0 point 130mmPb and Drape attenuation size should be less than 430 into 350mm to have effective shadow zone and weight should be maximum of 400 gm Mandatory Requirements with document proof Must have clinically proven efficacy in reducing operator scatter exposure from 70 to 95percent and must have minimum two clinical publications in pub med indexed journal Material composite construction ensuring zero secondary fluorescent backscattering to the patient supported by Study proof Core Material must be free from environmental hazards and supported by peer reviewed published studies and environmental safety document Disposal process IFU declaration should certify that drapes can be disposed like regular drapes used in cath lab | 250 | pieces | 90 |
| 6 | 6 EP subclavian shield | Drape or shield should be absorbable material non vinyl non rubber and 100 percent Lead free Must be single or bilayer technology sterilized chemical gas radiation and fit for safety during EP Device Procedures Quoted model code should have latest twelve months Old BARC test certificate Should have valid IS0 13485 2016 from notified body CE certified as per latest 500 directive EU 2017 745 from notified body relevant MD license from CDSCO with status mentioned as sterilized shield Manufacturer supplier should have ICMED certification LE should not be greater than 0 point 130mmPb and Drape attenuation size should be less than 430 into 350mm to have effective shadow zone and weight should be maximum of 400 gm Mandatory Requirements with document proof Must have clinically proven efficacy in reducing operator scatter exposure from 70 to 95percent and must have minimum two clinical publications in pub med indexed journal Material composite construction ensuring zero secondary fluorescent backscattering to the patient supported by Study proof Core Material must be free from environmental hazards and supported by peer reviewed published studies and environmental safety document Disposal process IFU declaration should certify that drapes can be disposed like regular drapes used in cath lab | 250 | pieces | 180 |
| 7 | 7 Head cover for radiation protection | Light weight disposable protective caps in all labs Must single or bilayer non vinyl non rubber 100 percent lead free technology Must be fit to all head sizes Quoted model code should have latest maximum twelve months old BARC test certificate Should have valid IS0 13485 2016 from notified body CE certified as per latest directive EU 2017 745 from notified body should have CDSCO certificate Manufacturer or supplier should have ICMED certification LE should not be greater than 0 point 130mmPb and Weight and attenuation size should be maximum of 580mm into 90 mm Mandatory Document needs to be Submitted Core Material must be free from environmental hazards and evidence Of non polluting during incineration Clinical evidence must be available with efficacy 70 to 90 percent Must be highly absorbent non Woven inner lining layers to keep perspiration 100 percent away during long operating cases Disposal process IFU declaration should certify that drapes can be disposed like regular drapes used in cath lab | 2500 | pieces | 90 |
| 8 | 8 Head cover for radiation protection | Light weight disposable protective caps in all labs Must single or bilayer non vinyl non rubber 100 percent lead free technology Must be fit to all head sizes Quoted model code should have latest maximum twelve months old BARC test certificate Should have valid IS0 13485 2016 from notified body CE certified as per latest directive EU 2017 745 from notified body should have CDSCO certificate Manufacturer or supplier should have ICMED certification LE should not be greater than 0 point 130mmPb and Weight and attenuation size should be maximum of 580mm into 90 mm Mandatory Document needs to be Submitted Core Material must be free from environmental hazards and evidence Of non polluting during incineration Clinical evidence must be available with efficacy 70 to 90 percent Must be highly absorbent non Woven inner lining layers to keep perspiration 100 percent away during long operating cases Disposal process IFU declaration should certify that drapes can be disposed like regular drapes used in cath lab | 2500 | pieces | 180 |