INDIAN ARMY has floated a tender for INSTALLATION OF DIGITAL INFO DISPLAY SCREEN FOR TRANSIENT AND TOURIST, Qty: 63. The project location is Tawang, Arunachal Pradesh, India. The reference number is - and it is closing on 26 Oct 2026. Suppliers can request Register free of cost to get the complete Tender details and download the document.
Procurement Summary
State: Arunachal Pradesh
Summary: INSTALLATION OF DIGITAL INFO DISPLAY SCREEN FOR TRANSIENT AND TOURIST, Qty: 63
Deadline: 26 Oct 2026
Posting Date: 16 Oct 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 151016189
Document Ref. No.: Login to see detail
Financier: Self Financed
Purchaser Ownership: Public
Document Fees: Refer Document
Tender Value: Refer Document
EMD: ₹ 5000
Purchaser's Detail
Name: Login to see details
Address: Login to see details
Email: Login to see details
Login to see detailsDocuments
| # | Title | Description | Qty | Unit | Delivery (Days) |
|---|---|---|---|---|---|
| 1 | Rcc Foundation by Footing | Material dash M20 grade RCC Typical Size by Thickness Approx 600 x 600 x 750 mm Foundation sized as per soil condition and wind load | 1 | Nos | 10 |
| 2 | PCC Layer | Material PCC Typical size 100 mm thick Tech Specification dash below RCC Footing | 1 | Nos | 10 |
| 3 | Reinforcement | Material TMT Steel Typical size dash 12mm mainby 8 dash 10 mm distribution tech specification spacing cage to structual design | 1 | Nos | 10 |
| 4 | Anchor Bolts | Material dash GI by HDG Typical size dash M16 by M20 Tech Specification Heavy dash duty bolts with nuts and washers | 1 | Nos | 10 |
| 5 | RCC Pedestal | Material M20 RCC Typical size Approx300 x 300 mm Tech Specification Raised pedestal above finished ground level | 15 | Kg | 10 |
| 6 | Main Pole | Material MS by GI squre pipe Typical Size 100 x 100 x 4 mm Tech Specification Heavy duty single pole support | 1 | Nos | 10 |
| 7 | Base Plate | Material MS Plate Typical Size 10-12 mm thick tech Specification Approx 250 x 250 by 300 x 300 mm final size by engineer | 1 | Nos | 10 |
| 8 | Gusset Plate | Material MS Plate Typical Size As Reqd Tech Specfication Strengthening between pole and base plate | 1 | Nos | 10 |
| 9 | Display Frame | Material MS by GI squre rectangular pipe Typical size 40 x 40 2 mm or 50 x 25 x 2 m Tech Specification frame fabricated to display dimensions | 1 | Nos | 10 |
| 10 | Display Unit | Material LED Digital Signage typical size As per Approved design Tech Specification secure mounted with service access | 1 | Nos | 10 |
| 11 | ACP Clading | Material exterior Grade ACP Typical Size 3 mm Tech Specification Clading on pole and Structual frame | 1 | Nos | 10 |
| 12 | ACP Border Bording | Material ACP Folded Sheet Typical Size Approx 50 dash 100 mm Tech Specification Neat folded corners and concealed fixing | 1 | Nos | 10 |
| 13 | Surface Treatment | material Primer plus exterior paint HDG Typical Size As specified tech specification Anti Corrosion protection for outdor use | 1 | Nos | 10 |
| 14 | cable management | Material Outdoor conduit Typical size As Required Tech Specification concealed vertical cable routing through pole | 1 | Nos | 10 |
| 15 | Electrical protection | material MCB SPD Earthing Typical size As required Tech Specification Waterproof instalation and proper earthing | 1 | Nos | 10 |
| 16 | febrication and welding | material MS GI fabrication typical size As per structural detail Tech Specification Continuous appropriate welds visible welds ground smooth | 1 | Nos | 10 |
| 17 | Excavation | As per structural drawing firm undisturbed bearing surface | 1 | Nos | 10 |
| 18 | PCC | 100 mm thick below RCC footing. | 1 | Nos | 10 |
| 19 | RCC Footing | M20 grade previous reference approx 600 x 600 x 750 mm final size to be recalculated for actual pole display and wind moment | 1 | Nos | 10 |
| 20 | Main Reinforcement | 12 mm dia TMT bar number spacing and cage arrangement as per structural design | 1 | Nos | 10 |
| 21 | Distribution Ties | 8 dash10 mm dia TMT spacing as per structural design | 1 | Nos | 10 |
| 22 | Concrete Cover | As per structural civil design maintain proper cover with spacers chairs | 1 | Nos | 10 |
| 23 | RCC Pedestal | Approx 300 x 300 mm raised above finished ground as required | 1 | Nos | 10 |
| 24 | Anchor Bolts | M16 M20 GI or HDG quantity diameter grade and bolt pattern as per base plate calculation | 1 | Nos | 10 |
| 25 | Anchor Template | MS template plate keep bolt centers accurate during RCC casting | 1 | Nos | 10 |
| 26 | Curing | Proper curing after casting not load erect before adequate concrete strength is achieved | 1 | Nos | 10 |
| 27 | Main Pole | 100 x100 x 4 mm MS GI square tube single pole support final section by engineer | 1 | Nos | 10 |
| 28 | Pole Height | Approx 12 ft above ground final height according to visibility and structural design | 1 | Nos | 10 |
| 29 | Base Plate | 10 dash12 mm MS plate typical 250 x 250 or 300 x 300 mm final plate by calculation | 1 | Nos | 10 |
| 30 | Gusset Plates | MS plate typically 6 dash 10 mm provided at polebase connection as required | 1 | Nos | 10 |
| 31 | Display Frame | 40x40x2 mm or 50x25x2 mm MS GI rigid perimeter intermediate members spacing to match cabinet module fixing points | 1 | Nos | 10 |
| 32 | Rear Support Grid | MS GI square rectangular tube size grade according to connection design provide locking arrangement where required | 1 | Nos | 10 |
| 33 | Fasteners | High strength GI HDG bolts nuts & washers locking arrangement where required | 1 | Nos | 10 |
| 34 | Welding | Qualified MS GI fabrication proper structural welds exposed visible welds to be ground smooth | 1 | Nos | 10 |
| 35 | LED Module | Common outdoor module format 320 x 160 mm fix into manufacturer approved cabinet module receiving surface | 1 | Nos | 10 |
| 36 | LED Cabinet | Common modular cabinet formats approx. 960 x 960 mm or 960 x 640 mm use exact cabinet size supplied with selected LED system | 1 | Nos | 10 |
| 37 | Cabinet Fixing | MS GI rear frame suitable brackets fasteners align cabinet rows columns level faces and maintain uniform joints | 1 | Nos | 10 |
| 38 | Module Alignment | Row by row column bycolumn correct orientation and pixelpitch continuity | 1 | Nos | 10 |
| 39 | Receiving Card | Inside cabinet signal orientation according to selected receiving card manufacturer arrangement | 1 | Nos | 10 |
| 40 | SMPS | Inside cabinet protected rear compartment quantity and wattage based on actual LED load | 1 | Nos | 10 |
| 41 | Service Access | Rear or front service maintain safe clearance for module SMPS and receiving card maintenance | 1 | Nos | 10 |
| 42 | Ventilation | Natural forced ventilation as cabinet design requires avoid blocked heat dissipation | 1 | Nos | 10 |
| 43 | AC Distribution | Dedicated protected supply MCB isolator sized from calculated load | 1 | Nos | 10 |
| 44 | SMPS Input | Properly rated outdoor cable to each cabinet section | 1 | Nos | 10 |
| 45 | DC Distribution | Manufacturer-approved DC wires connectors correct polarity and cable size | 1 | Nos | 10 |
| 46 | Signal Chain | Controller sending system receiving cards module data chain | 1 | Nos | 10 |
| 47 | Power and Signal Separation | Route power and signal wiring neatly avoid unnecessary parallel runs | 1 | Nos | 10 |
| 48 | Cable Protection | UV/weather resistant conduit flexible conduit or suitable cable protection | 1 | Nos | 10 |
| 49 | Cable Entry | Weatherproof glands sealed entries and drip loops | 1 | Nos | 10 |
| 50 | Earthing | Bond metal structure and electrical equipment as required by electrical design | 1 | Nos | 10 |
| 51 | SPD | Surge protection recommended selected according to electrical design | 1 | Nos | 10 |
| 52 | Testing | Continuity polarity insulation earthing signal sequence and full display load test | 1 | Nos | 10 |
| 53 | ACP Sheet | 3 mm exterior grade ACP approved colour texture | 1 | Nos | 10 |
| 54 | Pole Cladding | 3 mm ACP folded panels neat folded returns concealed mechanically secure fixing | 1 | Nos | 10 |
| 55 | Display Border | Approx 50 100 mm visible border uniform width around display | 1 | Nos | 10 |
| 56 | Side Return Depth | As per actual cabinet frame depth measure before ACP folding | 1 | Nos | 10 |
| 57 | Corners | Folded bent where practical clean aligned corners | 1 | Nos | 10 |
| 58 | Joints | Exteriorgrade neutralcure silicone approved sealant weather sealed neat finish | 1 | Nos | 10 |
| 59 | Bottom Closure | ACP closure skirting as required keep drainageservice access where needed | 1 | Nos | 10 |
| 60 | MS Steel | Clean degrease suitable anti corrosion primer exterior-grade top coat | 1 | Nos | 10 |
| 61 | Exposed Outdoor Steel | Prefer hot dip galvanizing where specified otherwise suitable epoxy PU paint system | 1 | Nos | 10 |
| 62 | Welded Areas | Clean slag spatter grind where appropriate and prime repaired areas before top coat | 1 | Nos | 10 |
| 63 | Final Colour | As per approved branding design ensure coating finish is compatible with primer | 1 | Nos | 10 |