Cross Icon
Cross Icon

INSTALLATION OF DIGITAL INFO DISPLAY SCREEN Tender - 151016189

INDIAN ARMY has floated a tender for INSTALLATION OF DIGITAL INFO DISPLAY SCREEN FOR TRANSIENT AND TOURIST, Qty: 63. The project location is Tawang, Arunachal Pradesh, India. The reference number is - and it is closing on 26 Oct 2026. Suppliers can request Register free of cost to get the complete Tender details and download the document.

Procurement Summary

State: Arunachal Pradesh

Summary: INSTALLATION OF DIGITAL INFO DISPLAY SCREEN FOR TRANSIENT AND TOURIST, Qty: 63

Deadline: 26 Oct 2026

Posting Date: 16 Oct 2026

Other Information

Notice Type: Tender

TOT Ref.No.: 151016189

Document Ref. No.: Login to see detail

Financier: Self Financed

Purchaser Ownership: Public

Document Fees: Refer Document

Tender Value: Refer Document

EMD: ₹ 5000

Purchaser's Detail

Name: Login to see details

Address: Login to see details

Email: Login to see details

  Login to see details

Documents

 Tender Notice

Bid_Document_9892723.pdf

Specification_Document.pdf

BOQ_Document.csv

Bill of Quantities (BOQ)

# Title Description Qty Unit Delivery (Days)
1 Rcc Foundation by Footing Material dash M20 grade RCC Typical Size by Thickness Approx 600 x 600 x 750 mm Foundation sized as per soil condition and wind load 1 Nos 10
2 PCC Layer Material PCC Typical size 100 mm thick Tech Specification dash below RCC Footing 1 Nos 10
3 Reinforcement Material TMT Steel Typical size dash 12mm mainby 8 dash 10 mm distribution tech specification spacing cage to structual design 1 Nos 10
4 Anchor Bolts Material dash GI by HDG Typical size dash M16 by M20 Tech Specification Heavy dash duty bolts with nuts and washers 1 Nos 10
5 RCC Pedestal Material M20 RCC Typical size Approx300 x 300 mm Tech Specification Raised pedestal above finished ground level 15 Kg 10
6 Main Pole Material MS by GI squre pipe Typical Size 100 x 100 x 4 mm Tech Specification Heavy duty single pole support 1 Nos 10
7 Base Plate Material MS Plate Typical Size 10-12 mm thick tech Specification Approx 250 x 250 by 300 x 300 mm final size by engineer 1 Nos 10
8 Gusset Plate Material MS Plate Typical Size As Reqd Tech Specfication Strengthening between pole and base plate 1 Nos 10
9 Display Frame Material MS by GI squre rectangular pipe Typical size 40 x 40 2 mm or 50 x 25 x 2 m Tech Specification frame fabricated to display dimensions 1 Nos 10
10 Display Unit Material LED Digital Signage typical size As per Approved design Tech Specification secure mounted with service access 1 Nos 10
11 ACP Clading Material exterior Grade ACP Typical Size 3 mm Tech Specification Clading on pole and Structual frame 1 Nos 10
12 ACP Border Bording Material ACP Folded Sheet Typical Size Approx 50 dash 100 mm Tech Specification Neat folded corners and concealed fixing 1 Nos 10
13 Surface Treatment material Primer plus exterior paint HDG Typical Size As specified tech specification Anti Corrosion protection for outdor use 1 Nos 10
14 cable management Material Outdoor conduit Typical size As Required Tech Specification concealed vertical cable routing through pole 1 Nos 10
15 Electrical protection material MCB SPD Earthing Typical size As required Tech Specification Waterproof instalation and proper earthing 1 Nos 10
16 febrication and welding material MS GI fabrication typical size As per structural detail Tech Specification Continuous appropriate welds visible welds ground smooth 1 Nos 10
17 Excavation As per structural drawing firm undisturbed bearing surface 1 Nos 10
18 PCC 100 mm thick below RCC footing. 1 Nos 10
19 RCC Footing M20 grade previous reference approx 600 x 600 x 750 mm final size to be recalculated for actual pole display and wind moment 1 Nos 10
20 Main Reinforcement 12 mm dia TMT bar number spacing and cage arrangement as per structural design 1 Nos 10
21 Distribution Ties 8 dash10 mm dia TMT spacing as per structural design 1 Nos 10
22 Concrete Cover As per structural civil design maintain proper cover with spacers chairs 1 Nos 10
23 RCC Pedestal Approx 300 x 300 mm raised above finished ground as required 1 Nos 10
24 Anchor Bolts M16 M20 GI or HDG quantity diameter grade and bolt pattern as per base plate calculation 1 Nos 10
25 Anchor Template MS template plate keep bolt centers accurate during RCC casting 1 Nos 10
26 Curing Proper curing after casting not load erect before adequate concrete strength is achieved 1 Nos 10
27 Main Pole 100 x100 x 4 mm MS GI square tube single pole support final section by engineer 1 Nos 10
28 Pole Height Approx 12 ft above ground final height according to visibility and structural design 1 Nos 10
29 Base Plate 10 dash12 mm MS plate typical 250 x 250 or 300 x 300 mm final plate by calculation 1 Nos 10
30 Gusset Plates MS plate typically 6 dash 10 mm provided at polebase connection as required 1 Nos 10
31 Display Frame 40x40x2 mm or 50x25x2 mm MS GI rigid perimeter intermediate members spacing to match cabinet module fixing points 1 Nos 10
32 Rear Support Grid MS GI square rectangular tube size grade according to connection design provide locking arrangement where required 1 Nos 10
33 Fasteners High strength GI HDG bolts nuts & washers locking arrangement where required 1 Nos 10
34 Welding Qualified MS GI fabrication proper structural welds exposed visible welds to be ground smooth 1 Nos 10
35 LED Module Common outdoor module format 320 x 160 mm fix into manufacturer approved cabinet module receiving surface 1 Nos 10
36 LED Cabinet Common modular cabinet formats approx. 960 x 960 mm or 960 x 640 mm use exact cabinet size supplied with selected LED system 1 Nos 10
37 Cabinet Fixing MS GI rear frame suitable brackets fasteners align cabinet rows columns level faces and maintain uniform joints 1 Nos 10
38 Module Alignment Row by row column bycolumn correct orientation and pixelpitch continuity 1 Nos 10
39 Receiving Card Inside cabinet signal orientation according to selected receiving card manufacturer arrangement 1 Nos 10
40 SMPS Inside cabinet protected rear compartment quantity and wattage based on actual LED load 1 Nos 10
41 Service Access Rear or front service maintain safe clearance for module SMPS and receiving card maintenance 1 Nos 10
42 Ventilation Natural forced ventilation as cabinet design requires avoid blocked heat dissipation 1 Nos 10
43 AC Distribution Dedicated protected supply MCB isolator sized from calculated load 1 Nos 10
44 SMPS Input Properly rated outdoor cable to each cabinet section 1 Nos 10
45 DC Distribution Manufacturer-approved DC wires connectors correct polarity and cable size 1 Nos 10
46 Signal Chain Controller sending system receiving cards module data chain 1 Nos 10
47 Power and Signal Separation Route power and signal wiring neatly avoid unnecessary parallel runs 1 Nos 10
48 Cable Protection UV/weather resistant conduit flexible conduit or suitable cable protection 1 Nos 10
49 Cable Entry Weatherproof glands sealed entries and drip loops 1 Nos 10
50 Earthing Bond metal structure and electrical equipment as required by electrical design 1 Nos 10
51 SPD Surge protection recommended selected according to electrical design 1 Nos 10
52 Testing Continuity polarity insulation earthing signal sequence and full display load test 1 Nos 10
53 ACP Sheet 3 mm exterior grade ACP approved colour texture 1 Nos 10
54 Pole Cladding 3 mm ACP folded panels neat folded returns concealed mechanically secure fixing 1 Nos 10
55 Display Border Approx 50 100 mm visible border uniform width around display 1 Nos 10
56 Side Return Depth As per actual cabinet frame depth measure before ACP folding 1 Nos 10
57 Corners Folded bent where practical clean aligned corners 1 Nos 10
58 Joints Exteriorgrade neutralcure silicone approved sealant weather sealed neat finish 1 Nos 10
59 Bottom Closure ACP closure skirting as required keep drainageservice access where needed 1 Nos 10
60 MS Steel Clean degrease suitable anti corrosion primer exterior-grade top coat 1 Nos 10
61 Exposed Outdoor Steel Prefer hot dip galvanizing where specified otherwise suitable epoxy PU paint system 1 Nos 10
62 Welded Areas Clean slag spatter grind where appropriate and prime repaired areas before top coat 1 Nos 10
63 Final Colour As per approved branding design ensure coating finish is compatible with primer 1 Nos 10

Corresponding Contract Award Notice

No Contract Award Notice found for this tender. Please try using the Contract Award Search Page.


Request Demo
GiZ Tenders India