CORPORATE OFFICE, GURGAON has floated a tender for Corrigendum: Upgradation of existing SAS, ATM (Air Traffic Management) Automation System (AAI), Qty: 177. The project location is Kurnool, Andhra Pradesh, India. The reference number is - and it is closing on 19 Oct 2026. Suppliers can request Register free of cost to get the complete Tender details and download the document.
Procurement Summary
State: Andhra Pradesh
Summary: Corrigendum: Upgradation of existing SAS, ATM (Air Traffic Management) Automation System (AAI), Qty: 177
Deadline: 19 Oct 2026
Posting Date: 13 Oct 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 150842693
Document Ref. No.: Login to see detail
Financier: Self Financed
Purchaser Ownership: Public
Document Fees: Refer Document
Tender Value: Refer Document
EMD: Refer Document
Purchaser's Detail
Name: Login to see details
Address: Login to see details
Email: Login to see details
Login to see detailsDocuments
| # | Title | Description | Qty | Unit | Delivery (Days) |
|---|---|---|---|---|---|
| 1 | Upgradation of existing SAS at Kurnool SS- Supply Portion | Supply of industrial grade PC with latest operating System (Windows 11) with 7 Years Support and with PC specifications as mentioned in SCOPE of work <br>i Server- 02 nos ii Client- 02 nos iii Gateway- 02 nos iv DR-EWS PC- 01 no V Historians - 02 Nos | 9 | No | 244 |
| 2 | Upgradation of existing SAS at Kurnool SS- Supply Portion | Supply of Next Generation Fire Walls(NGFW) as per the POWERGRID specifications | 2 | No | 244 |
| 3 | Upgradation of existing SAS at Kurnool SS- Supply Portion | Monitors- 27 Inch | 4 | No | 244 |
| 4 | Upgradation of existing SAS at Kurnool SS- Supply Portion | Loading of latest SCADA and other software licensed version in Servers-HMIs- Gateways and DR-EWS PCs compatible with latest OS Version with Seven Year patch support | 1 | Lot | 244 |
| 5 | Upgradation of existing SAS at Kurnool SS- Supply Portion | Configuration and software loading in PC (Supply and installation of Antivirus, Network management system and other softwares ) licensed | 1 | Lot | 244 |
| 6 | Upgradation of existing SAS at Kurnool SS- Supply Portion | Engineering, loading and testing & Commissioning of new database | 1 | Lot | 244 |
| 7 | Upgradation of existing SAS at Kurnool SS- Supply Portion | Ethernet Switches with 12CU plus 12 FO. | 2 | EA | 244 |
| 8 | Upgradation of existing SAS at Kurnool SS- Supply Portion | GPS with POWERGRID TS | 1 | SET | 244 |
| 9 | Upgradation of existing SAS at Kurnool SS- Supply Portion | Inverters 2KVA | 2 | SET | 244 |
| 10 | Upgradation of existing SAS at Kurnool SS- Supply Portion | Bay control Unit ( For Swapping during Firmware Upgrdataion) | 1 | EA | 244 |
| 11 | Upgradation of existing SAS at Kurnool SS- Supply Portion | Patch Cords | 2 | SET | 244 |
| 12 | Upgradation of existing SAS at Kurnool SS- Service Portion | Final Data base modification at site, testing and <br>commissioning limited to 30 days | 30 | ManDays | 244 |
| 13 | Upgradation of existing SAS at Kurnool SS- Service Portion | Installation and commissioning of Next Generation Fire Walls(NGFW) as per the Powergrid Specifications | 2 | No | 244 |
| 14 | Upgradation of existing SAS at Raichur SS- Supply Portion | Supply of industrial grade PC with latest operating System(Windows 11) with 7 Years Support and with PC specifications as mentioned in SCOPE of work <br>i) Server- 03 nos ii) Client- 02 nos iii) Gateway- 02 nos iv) DR/EWS PC- 01 no V)Historians - 02 Nos | 10 | No | 244 |
| 15 | Upgradation of existing SAS at Raichur SS- Supply Portion | Supply of Next Generation Fire Walls(NGFW) as per the POWERGRID specifications | 2 | No | 244 |
| 16 | Upgradation of existing SAS at Raichur SS- Supply Portion | Monitors- 27 Inch | 4 | No | 244 |
| 17 | Upgradation of existing SAS at Raichur SS- Supply Portion | Loading of latest SCADA and other software licensed version in Servers -HMIs-Gateways and DR-EWS PCs compatible with latest OS Version with Seven Year patch support | 1 | Lot | 244 |
| 18 | Upgradation of existing SAS at Raichur SS- Supply Portion | Configuration and software loading in PC (Supply and installation of Antivirus, Network management system and other softwares ) licensed | 1 | Lot | 244 |
| 19 | Upgradation of existing SAS at Raichur SS- Supply Portion | Engineering, loading and testing & Commissioning of new database | 1 | Lot | 244 |
| 20 | Upgradation of existing SAS at Raichur SS- Supply Portion | Ethernet Switches with 12CU plus 12 FO. | 2 | EA | 244 |
| 21 | Upgradation of existing SAS at Raichur SS- Supply Portion | GPS with POWERGRID TS | 1 | SET | 244 |
| 22 | Upgradation of existing SAS at Raichur SS- Supply Portion | Inverters 2KVA | 2 | SET | 244 |
| 23 | Upgradation of existing SAS at Raichur SS- Supply Portion | Bay control Unit ( For Swapping during Firmware Upgrdataion) | 1 | EA | 244 |
| 24 | Upgradation of existing SAS at Raichur SS- Supply Portion | Patch Cords | 2 | SET | 244 |
| 26 | Upgradation of existing SAS at Raichur SS- Service Portion | Final Data base modification at site, testing and <br>commissioning limited to 30 days | 30 | ManDays | 244 |
| 27 | Upgradation of existing SAS at Raichur SS- Service Portion | Installation and commissioning of Next Generation Fire Walls(NGFW) as per the Powergrid Specifications | 2 | No | 244 |
| 28 | Upgradation of existing SAS at Nellore PS- Supply Portion | Supply of industrial grade PC with latest operating System(Windows 11) with 7 Years Support. And with PC specifications as mentioned in SCOPE of work <br>i) Server- 03 nos ii) Client- 02 nos iii) Gateway- 02 nos iv) DR/EWS PC- 02 no V)Historians - 02 Nos | 11 | No | 244 |
| 29 | Upgradation of existing SAS at Nellore PS- Supply Portion | Supply of Next Generation Fire Walls(NGFW) as per the POWERGRID specifications | 2 | No | 244 |
| 30 | Upgradation of existing SAS at Nellore PS- Supply Portion | Monitors- 27 Inch | 4 | No | 244 |
| 31 | Upgradation of existing SAS at Nellore PS- Supply Portion | Loading of latest SCADA and other software licensed version in Servers -HMIs- Gateways and DR-EWS PCs compatible with latest OS Version with Seven Year patch support | 1 | Lot | 244 |
| 32 | Upgradation of existing SAS at Nellore PS- Supply Portion | Configuration and software loading in PC (Supply and installation of Antivirus, Network management system and other softwares ) licensed | 1 | Lot | 244 |
| 33 | Upgradation of existing SAS at Nellore PS- Supply Portion | Engineering, loading and testing & Commissioning of new database | 1 | Lot | 244 |
| 34 | Upgradation of existing SAS at Nellore PS- Supply Portion | Ethernet Switches with 12CU plus 12 FO. | 2 | EA | 244 |
| 35 | Upgradation of existing SAS at Nellore PS- Supply Portion | GPS with POWERGRID TS | 1 | SET | 244 |
| 36 | Upgradation of existing SAS at Nellore PS- Supply Portion | Inverters 2KVA | 2 | SET | 244 |
| 37 | Upgradation of existing SAS at Nellore PS- Supply Portion | Bay control Unit ( For Swapping during Firmware Upgrdataion) | 1 | EA | 244 |
| 38 | Upgradation of existing SAS at Nellore PS- Supply Portion | Patch Cords | 2 | SET | 244 |
| 39 | Upgradation of existing SAS at Nellore PS- Service Portion | Final Data base modification at site, testing and <br>commissioning limited to 30 days | 30 | ManDays | 244 |
| 40 | Upgradation of existing SAS at Nellore PS- Service Portion | Installation and commissioning of Next Generation Fire Walls(NGFW) as per the Powergrid Specifications | 2 | No | 244 |