The AIRPORTS AUTHORITY OF INDIA (AAI) has issued a Tender notice for the procurement of a Corrigendum: SITC of 10 KVA Modular UPS Nav Aids and VHF Facilities at IGI Airport New Delhi, Qty: 5243 in the India.The project location is South West Delhi, Delhi (NCT), India. This Tender notice was published on 02 Nov 2026 and is scheduled to close on 04 Nov 2026, with an estimated Tender value of 116842242. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 151851011, while the tender notice number is GEM/2026/B/8036781 and Register on the platform.
Purchaser contact is for registered users
Login to see details| # | Title | Description | Qty | Unit | Delivery (Days) |
|---|---|---|---|---|---|
| 1 | N plus1 Modular type 10 KVA UPS | N plus1 Modular type 10 KVA UPS | 42 | Number | 90 |
| 2 | Static Transfer Switch with 24U rack with power strip | Static Transfer Switch with 24U rack with power strip | 26 | Number | 90 |
| 3 | Surge Protection Devices Class B plus C or Type 1 plus 2 | Surge Protection Devices Class B plus C or Type 1 plus 2 | 42 | Number | 90 |
| 4 | Surge Protection Devices Class C or Type | Surge Protection Devices Class C or Type | 42 | Number | 90 |
| 5 | Client station CPU with 55 inch or bigger LED | Client station CPU with 55 inch or bigger LED | 1 | lot | 90 |
| 6 | Client PC with 23 inch monitor along with other accessories | Client PC with 23 inch monitor along with other accessories | 1 | lot | 90 |
| 7 | UPS CMS Server each with 23 inch Display | UPS CMS Server each with 23 inch Display | 2 | lot | 90 |
| 8 | UPS CMS software for server and client position | UPS CMS software for server and client position | 1 | Lot | 90 |
| 9 | Isolation Transformer | Isolation Transformer | 50 | Number | 90 |
| 10 | Fire resistant cable multi strand 03 Core 6 sq mm | Fire resistant cable multi strand 03 Core 6 sq mm | 1200 | Meters | 90 |
| 11 | Type B curve double pole MCBs 32 Amp | Type B curve double pole MCBs 32 Amp | 126 | Number | 90 |
| 12 | Type B curve double pole MCBs 63 Amp | Type B curve double pole MCBs 63 Amp | 84 | Number | 90 |
| 13 | Wall mounted polycarbonate enclosure with transparent door | Wall mounted polycarbonate enclosure with transparent door | 105 | Number | 90 |
| 14 | Metallic square channel minimum 3 inches wide | Metallic square channel minimum 3 inches wide | 700 | Meters | 90 |
| 15 | Stainless steel Flexible conduits minimum 1point5 inches wide | Stainless steel Flexible conduits minimum 1point5 inches wide | 360 | Meters | 90 |
| 16 | Heavy duty Copper Lugs or Thimbles as per power cables | Heavy duty Copper Lugs or Thimbles as per power cables | 1820 | Number | 90 |
| 17 | Metallic Cable Glands as per outer diameter of power cables | Metallic Cable Glands as per outer diameter of power cables | 240 | Number | 90 |
| 18 | Single core multistrand 6 sq mm copper cable | Single core multistrand 6 sq mm copper cable | 400 | Meters | 90 |
| 19 | Cost of Installation Integration Testing and Commissioning of complete system | Cost of Installation Integration Testing and Commissioning of complete system | 1 | LOT | 180 |