The MUMBAI PORT TRUST has issued a Tender notice for the procurement of a Corrigendum: Providing Shore Power Charging Infrastructure for Green Tug, Qty: 2554 in the India.The project location is Mumbai, Maharashtra, India. This Tender notice was published on 26 Nov 2026 and is scheduled to close on 07 Dec 2026, with an estimated Tender value of 47932890. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 153047987 and Register on the platform.
Purchaser contact is for registered users
Login to see detailsTender details are for registered users
Login to see details| # | Title | Description | Qty | Unit | Delivery (Days) |
|---|---|---|---|---|---|
| 1 | HT panel | Supply of HT panel as per Item specification item no 1 | 1 | set | 300 |
| 2 | HT panel | ITC of HT panel | 1 | job | 300 |
| 3 | Transformer | Supply of dry type transformer as per item no 2 | 2 | Set | 300 |
| 4 | Transformer | ITC of dry type transformer | 1 | job | 300 |
| 5 | LT panel | Supply of LT panel as per item no 3 | 1 | set | 300 |
| 6 | LT panel | ITC of LT panel | 1 | job | 300 |
| 7 | Auxillary transformer | Supply of Auxillary type transformer as per item no 4 | 1 | set | 300 |
| 8 | Auxillary transformer | ITC of Auxillary transformer | 1 | job | 300 |
| 9 | APFC Panel | Supply of APFC panel as per item no 5 | 1 | set | 300 |
| 10 | APFC Panel | ITC of APFC panel | 1 | job | 300 |
| 11 | UPS | Supply of UPS as per itm no 6 | 1 | set | 300 |
| 12 | UPS | ITC of UPS | 1 | job | 300 |
| 13 | Fire alarm system | Supply of fire alarm system as per item no 7 | 1 | set | 300 |
| 14 | Fire alarm system | ITC of fire alarm system | 1 | job | 300 |
| 15 | fire extinguisher | Supply of fire extinguisher as per item no 8 | 1 | job | 300 |
| 16 | fire extinguisher | ITC of fire extinguisher | 1 | job | 300 |
| 17 | HT termination kit | Supply of HT termination kit as per item no 9 | 8 | number | 300 |
| 18 | HT termination kit | ITC of HT termination kit | 8 | job | 300 |
| 19 | LT termination kit | supply of LT termination kit as per item no 10 | 16 | number | 300 |
| 20 | LT termination kit | ITC of LT termination kit | 16 | job | 300 |
| 21 | 300 sq mm termination | cable end termination 300 sq mm as per item no 11 | 4 | set | 300 |
| 22 | 185 sq mm termination | cable end termination 185 sq mm as per item no 12 | 2 | set | 300 |
| 23 | 95 sq mm termination | cable end termination 95 sq mm as per item no 13 | 2 | set | 300 |
| 24 | Earthing | Supply of chemical earthing as per item no 14 | 16 | set | 300 |
| 25 | Earthing strip | Galvanized earthing strip | 350 | meters | 300 |
| 26 | Earthing strip | copper earthing strip | 100 | meters | 300 |
| 27 | Lighting arrestor | SITC of lighting arrestor | 2 | numbers | 300 |
| 28 | Earthing for LA | Earthing for lighting arrestor | 2 | numbers | 300 |
| 29 | 630 sq mm copper cable | Supply of 1C 630 sq mm copper cable as per item no 15 | 300 | meters | 300 |
| 30 | 400 sq mm copper cable | supply of 3C 400 sq mm Aluminium cable as per item no 16 | 600 | meters | 300 |
| 31 | Tracing | Tracing of HT cable as per item no 17 | 2 | numbers | 300 |
| 32 | Straight through joint | Supply of straight through joint 400 sq mm as per item no 18 | 4 | numbers | 300 |
| 33 | Straight through joint | Making of straight through joint 400 sq mm as per item no 19 | 4 | numbers | 300 |
| 34 | High pot test | Carrying out high potential test as per item no 20 | 4 | job | 300 |
| 35 | Phase sequence test | Carrying out phase sequence test as per item no 21 | 4 | job | 300 |
| 36 | Excavation | Excavation of soft soil as per item no 22 | 135 | cubic meters | 300 |
| 37 | Excavation | Excavation of concrete as per item no 23 | 45 | cubic meters | 300 |
| 38 | Laying of cable | laying of HT cable as per item no 24 | 600 | meters | 300 |
| 39 | Excavation | Excavation of soft soil as per item no 25 | 1 | lot | 300 |
| 40 | Excavation | Excavation of concrete as per item no 26 | 1 | lot | 300 |
| 41 | RCC pipe | supply and laying of 250 mm diameter RCC pipe as per item no 27 | 80 | meters | 300 |
| 42 | RCC pipe | supply and laying of 450 mm diameter RCC pipe as per item no 28 | 20 | meters | 300 |
| 43 | Inspection chamber | Construction of inspection chamber as per item no 29 | 3 | job | 300 |
| 44 | Wiring | Wiring for LED tube light as per item no 30 | 30 | numbers | 300 |
| 45 | Wiring | Wiring for ceiling fan as per item no 30 | 10 | numbers | 300 |
| 46 | Wiring | Two Wall socket outlet points as per item no 31 | 10 | numbers | 300 |
| 47 | Power socket | Single pole MCB Protected Power socket outlet point as per item no 32 | 8 | numbers | 300 |
| 48 | TPN MCB point | SITC of MCB Protected Power socket outlet point as per item no 33 | 3 | numbers | 300 |
| 49 | fittings | SITC of LED tube light as per item no 34 | 25 | numbers | 300 |
| 50 | fittings | SITC of BLDC fans as per item no 35 | 10 | numbers | 300 |
| 51 | fittings | SITC of Exhaust fans as per item no 36 | 7 | numbers | 300 |
| 52 | TPN DB | SITC of TPN 12 way DB as per item no 37 | 1 | numbers | 300 |
| 53 | Civil work | Excavation of trench inside substation as per item no 38 | 34 | cubic meters | 300 |
| 54 | Civil work | construction wall on trench as per item no 39 | 7 | cubic meters | 300 |
| 55 | Civil work | Removing existing window and providing new as per item no 40 | 1 | job | 300 |
| 56 | Reinstatement | Providing and laying WBM as per item no 41 sub 1 | 25 | square meter | 300 |
| 57 | Reinstatement | Providing and laying sub base as per item no 41 sub 2 | 25 | square meter | 300 |
| 58 | Reinstatement | Providing and laying M10 grade ready mix as per item no 41 sub 3 | 3 | cubic meters | 300 |
| 59 | Reinstatement | Providing and laying cement concrete as per item no 41 sub 4 | 9 | cubic meters | 300 |