Login
Register
Complete Your Profile
Change Password
Request a Password Reset
Download Documents
Download Documents
Get Help to Participate in This Tender
Our team will contact you shortly.
Your activation form is pending.
Please submit it to start receiving email alerts.
Submit NowChange Password
For better security, update the account password.
BHARAT SANCHAR NIGAM LIMITED (BSNL) has floated a tender for Call base repairing general servicing and Down Sizing of DG, Qty: 181. The project location is Junagadh, Gujarat, India. The reference number is - and it is closing on 29 Oct 2026. Suppliers can request Register free of cost to get the complete Tender details and download the document.
Procurement Summary
State: Gujarat
Summary: Call base repairing general servicing and Down Sizing of DG, Qty: 181
Deadline: 29 Oct 2026
Posting Date: 19 Oct 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 151164407
Document Ref. No.: Login to see detail
Financier: Self Financed
Purchaser Ownership: Public
Document Fees: Refer Document
Tender Value: ₹ 519825
EMD: ₹ 10397
Purchaser's Detail
Name: Login to see details
Address: Login to see details
Email: Login to see details
Login to see detailsDocuments
| # | Title | Description | Qty | Unit | Delivery (Days) |
|---|---|---|---|---|---|
| 1 | Attending the DG through skilled mechanic with minor new material for distance 0 to 50KM | As per ATC Schedule Item | 2 | Job | 365 |
| 2 | Attending the DG through skilled mechanic with minor new material for distance 51 to 100KM | As per ATC Schedule Item | 2 | Job | 365 |
| 3 | Attending the DG through skilled mechanic with minor new material for distance 101 to 250KM | As per ATC Schedule Item | 1 | Job | 365 |
| 4 | Replacement of recommended grade lubricating engine oil, element type lube oil filter for DG sets 15 to 32.5 KVA | As per ATC Schedule Item | 2 | Job | 365 |
| 5 | Replacement of recommended grade lubricating engine oil, element type lube oil filter for DG sets 40 to 62.5 KVA | As per ATC Schedule Item | 2 | Job | 365 |
| 6 | Replacement of recommended grade lubricating engine oil, element type lube oil filter for DG sets 100 to 125 KVA | As per ATC Schedule Item | 1 | Job | 365 |
| 7 | Replacement of recommended grade lubricating engine oil, element type lube oil filter for DG sets 126 to 250 KVA | As per ATC Schedule Item | 1 | Job | 365 |
| 8 | Supplying and fixing of the SMPS type electronic Battery Charger for 12 volt starting Battery | As per ATC Schedule Item | 3 | Job | 365 |
| 9 | Supplying and fixing of the SMPS type electronic Battery Charger for 24 volt starting Battery | As per ATC Schedule Item | 2 | Job | 365 |
| 10 | Supplying and fixing for DG sets Hose pipe | As per ATC Schedule Item | 4 | Nos | 365 |
| 11 | Supplying and fixing for DG sets Metallic Braided fuel pipe | As per ATC Schedule Item | 2 | Nos | 365 |
| 12 | Supplying and fixing for DG sets V Belt set | As per ATC Schedule Item | 1 | Nos | 365 |
| 13 | Supplying and fixing for DG sets lubricating engine oil | As per ATC Schedule Item | 20 | Ltr | 365 |
| 14 | Supplying and fixing for DG sets Stop solenoid of 5 Kg pressure | As per ATC Schedule Item | 1 | Nos | 365 |
| 15 | Repairing servicing of the Self starter up to 500 KVA capacity EA set with Brushes and Spring | As per ATC Schedule Item | 1 | set | 365 |
| 16 | Repairing servicing of the Self starter up to 500 KVA capacity EA set with Pinion | As per ATC Schedule Item | 1 | Nos | 365 |
| 17 | Repairing servicing of the Self starter up to 500 KVA capacity EA set with Solenoid relay | As per ATC Schedule Item | 2 | Nos | 365 |
| 18 | Repairing servicing of the Self starter up to 500 KVA capacity EA set with starting relay | As per ATC Schedule Item | 1 | Nos | 365 |
| 19 | Calibration of the fuel pump nozzle from the authorized workshop with For 2 to 6 Cylinder pump | As per ATC Schedule Item | 1 | Job | 365 |
| 20 | Calibration of the fuel pump nozzle from the authorized workshop with For 8 to 12 Cylinder pump | As per ATC Schedule Item | 1 | Job | 365 |
| 21 | Supplying fixing of the electrical components in the EA set panel with LED type indication lamp | As per ATC Schedule Item | 10 | Nos | 365 |
| 22 | Supplying fixing of the electrical components in the EA set panel with Pla relay with base | As per ATC Schedule Item | 1 | Nos | 365 |
| 23 | Supplying fixing of the electrical components in the EA set panel with Battery charger toggle switch | As per ATC Schedule Item | 1 | Nos | 365 |
| 24 | Supplying fixing of the electrical components in the EA set panel with HRC fuse HN type | As per ATC Schedule Item | 5 | Nos | 365 |
| 25 | Supplying fixing of the electrical components in the EA set panel with Push button | As per ATC Schedule Item | 2 | Nos | 365 |
| 26 | Supplying fixing of the electrical components in the EA set panel with Ignition Key assembly | As per ATC Schedule Item | 1 | Nos | 365 |
| 27 | Supplying fixing of the electrical components in the EA set panel with copper conductor battery wire with lug | As per ATC Schedule Item | 2 | Nos | 365 |
| 28 | Supplying fixing of the electrical components in the EA set panel with battery terminal socket | As per ATC Schedule Item | 6 | Nos | 365 |
| 29 | Supplying fixing of the electrical components in the EA set panel with Diesel Hand pump | As per ATC Schedule Item | 1 | Nos | 365 |
| 30 | Supplying fixing of the electrical components in the EA set panel with Digital Frequency meter | As per ATC Schedule Item | 1 | Nos | 365 |
| 31 | Supplying fixing of the electrical components in the EA set panel with AC Voltmeter Analog 72 mm x72 mm | As per ATC Schedule Item | 1 | Nos | 365 |
| 32 | Supplying fixing of the electrical components in the EA set panel with AC Voltmeter Analogue 96 mm x 96 mm | As per ATC Schedule Item | 1 | Nos | 365 |
| 33 | Supplying fixing of the electrical components in the EA set panel with DC Voltmeter Analogue 72 mm x72 mm | As per ATC Schedule Item | 1 | Nos | 365 |
| 34 | Supplying fixing of the electrical components in the EA set panel with DC Voltmeter Analogue 96 mm x 96 mm | As per ATC Schedule Item | 1 | Nos | 365 |
| 35 | Supplying fixing of the electrical components in the EA set panel with AC Ammeter Analog 96 mm x 96 mm | As per ATC Schedule Item | 1 | Nos | 365 |
| 36 | Supplying fixing of the electrical components in the EA set panel with AC Ammeter Analog 72 mm x72 mm | As per ATC Schedule Item | 1 | Nos | 365 |
| 37 | Supplying fixing of the electrical components in the EA set panel with DC Ammeter Analog 96 mm x 96 mm | As per ATC Schedule Item | 1 | Nos | 365 |
| 38 | Supplying fixing of the electrical components in the EA set panel with DC Ammeter Analog 72 mm x72 mm | As per ATC Schedule Item | 1 | Nos | 365 |
| 39 | Supplying fixing of the electrical components in the EA set panel with Volt Selector Switch for Voltmeter | As per ATC Schedule Item | 1 | Nos | 365 |
| 40 | Supplying fixing of the electrical components in the EA set panel with 250 Amp Changeover Handle | As per ATC Schedule Item | 1 | Nos | 365 |
| 41 | Supplying fixing of the electrical components in the EA set panel with Analogue type RPM meter | As per ATC Schedule Item | 1 | Nos | 365 |
| 42 | Supplying fixing of the electrical components in the EA set panel with LLOP Sensor for EA set of 15 to 160 KVA | As per ATC Schedule Item | 1 | Nos | 365 |
| 43 | Supplying fixing of the electrical components in the EA set panel with Water pump for liquid cooling system for 15 to 50 KVA | As per ATC Schedule Item | 1 | Nos | 365 |
| 44 | Supplying fixing of the electrical components in the EA set panel with Water pump for liquid cooling system for 110 to 160 KVA | As per ATC Schedule Item | 1 | Nos | 365 |
| 45 | Supplying fixing of the electrical components in the EA set panel with Rubber Metal Gasket for Nozzle of Engine | As per ATC Schedule Item | 1 | Nos | 365 |
| 46 | Supplying fixing of the electrical components in the EA set panel with Radiator MS 6 spoke Fan Blade | As per ATC Schedule Item | 1 | Nos | 365 |
| 47 | Replacement of AVR in Existing Alternator for 15 KVA to 62.5KVA | As per ATC Schedule Item | 1 | Job | 365 |
| 48 | Replacement of AVR in Existing Alternator for above 62.5 KVA Up to 250KVA | As per ATC Schedule Item | 1 | Job | 365 |
| 49 | Servicing of radiator of below capacity EA 15 KVA to 62.5KVA | As per ATC Schedule Item | 1 | Job | 365 |
| 50 | Servicing of radiator of below capacity EA 62.5 KVA to 250KVA | As per ATC Schedule Item | 1 | Job | 365 |
| 51 | Repairing Servicing of radiator of up to 250 KVA EA set including replacement of radiator water and Coolant | As per ATC Schedule Item | 1 | Job | 365 |
| 52 | Dismantling Shifting of various capacity and type DG set with all accessories 15 KVA to 32.5 KVA upto 50KM | As per ATC Schedule Item | 1 | Job | 365 |
| 53 | Dismantling, Shifting of various capacity and type DG set with all accessories 34 KVA to 62.5 KVA upto 50KM | As per ATC Schedule Item | 1 | Job | 365 |
| 54 | Transporting of below capacity DG set with all accessories beyond 50 km for 15 KVA to 62.5KVA | As per ATC Schedule Item | 30 | km | 365 |
| 55 | Transporting of below capacity DG set with all accessories beyond 50 km for 63 KVA to 125 KVA | As per ATC Schedule Item | 30 | km | 365 |
| 56 | Dismantling, Shifting of various capacity and type DG set with all accessories 15 KVA to 32.5 KVA within same compound | As per ATC Schedule Item | 1 | Job | 365 |
| 57 | Dismantling, Shifting of various capacity and type DG set with all accessories 34 KVA to 62.5 KVA within same compound | As per ATC Schedule Item | 1 | Job | 365 |
| 58 | Dismantling, Shifting of various capacity and type DG set with all accessories 63 KVA to 125 KVA within same compound | As per ATC Schedule Item | 1 | Job | 365 |
| 59 | Dismantling, Shifting of various capacity and type DG set with all accessories 126 KVA to 250 KVA within same compound | As per ATC Schedule Item | 1 | Job | 365 |
| 60 | ITC of various capacity type DG set with fuel tank, control panel 15 KVA to 33.5 KVA | As per ATC Schedule Item | 2 | Job | 365 |
| 61 | ITC of various capacity type DG set with fuel tank, control panel 34 KVA to 62.5 KVA | As per ATC Schedule Item | 1 | Job | 365 |
| 62 | Supply of MS C class heavy duty pipe 80 mm diameter | As per ATC Schedule Item | 1 | mtr | 365 |
| 63 | Supply of MS C class heavy duty pipe 100 mm diameter | As per ATC Schedule Item | 1 | mtr | 365 |
| 64 | Supply of MS C class heavy duty pipe 125 mm diameter | As per ATC Schedule Item | 1 | mtr | 365 |
| 65 | Supplying, installation testing of 12 Volt low maintenance type lead acid battery 88 AH, 100 AH | As per ATC Schedule Item | 2 | Job | 365 |
| 66 | Supplying, installation testing of 12 Volt low maintenance type lead acid battery 120, 130 AH | As per ATC Schedule Item | 2 | Job | 365 |
| 67 | Primary visit of EA sets at TEs under Junagadh BA Before Shifting of EA to Another Building for 0-50 KM | As per ATC Schedule Item | 1 | Job | 365 |
| 68 | Primary visit of EA sets at TEs under Junagadh BA Before Shifting of EA to Another Building for 51-100 KM | As per ATC Schedule Item | 1 | Job | 365 |
| 69 | Primary visit of EA sets at TEs under Junagadh BA Before Shifting of EA to Another Building for 101-200 KM | As per ATC Schedule Item | 1 | Job | 365 |
Corresponding Contract Award Notice
No Contract Award Notice found for this tender. Please try using the Contract Award Search Page.
Sign in with Google