Open for bids Tender India NCB TOT Ref. 152814010

BoQ 1234, AutomationTestCategory_DoNotUse, Qty Tender - 152814010

Tender notice from India, published on 21 Nov 2026.

Executive Summary

The CONTROLLER GENERAL OF DEFENCE ACCOUNTS has issued a Tender notice for the procurement of a BoQ 1234, AutomationTestCategory_DoNotUse, Qty: 1182 in the India.The project location is Kangra, Himachal Pradesh, India. This Tender notice was published on 21 Nov 2026 and is scheduled to close on 30 Nov 2026, with an estimated Tender value of Refer Document. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 152814010 and Register on the platform.

Key facts

Summary
BoQ 1234, AutomationTestCategory_DoNotUse, Qty: 1182
TOT Ref. No.
152814010
Document Ref. No.
Login to see
City
Kangra
State
Himachal Pradesh
Notice type
Tender
Competition
NCB
Publication date
21 Nov 2026
Bid deadline
30 Nov 2026
EMD
194000
Tender value
Refer Document
Purchaser ownership
Public
Financier
Self Financed

CPV classification

Purchaser details

Purchaser contact is for registered users

Login to see details

Tender details

Tender details are for registered users

Login to see details

Documents

Tender Notice
Login to view
Bid_Document_10183479.pdf
Login to view
Specification_Document.pdf
Login to view
BOQ_Document.csv
Login to view

Bill of Quantities (BOQ)

# Title Description Qty Unit Delivery (Days)
1 Disconnecting Disassembling and other works mentioned in item description of washing machine capacity 30kg Disconnecting Disassembling taking out old washing machine and deposit to MES store yard and Supply installation testing and commssioning of a heavy duty industrial front loading washing machine capacity of 30 kG to the designated laundry site positioning leveling and rigidly mounting the machine onto a concrete foundation base using heavy duty anti vibration pads and anchor bolts making connections including hot and cold water inlets lines as specified drainage and electrical power supplies and testing at full capacity and checking for leaks or balacing issue Control system fully programmable microprocessor controller with a user firendly digital display with heavy duty motor with variable fequency drive for smooth acceration programmable wash and smart out of balance load detection complete with all standard accesssories connection and complete detailed complete all as specified and directed PLEASE NOTE Make of machine STEFAB OBLIQUE FABCARE OBLIQUE LEMISON 1 Nos 90
2 Disconnecting Disassembling and other works mentioned in item description of Hydra Extractor machine capacity 15kg Disconnecting Disassembling taking out old hydra extractor machine and deposit to MES store yard and Supply installation testing and commissioning of 15 Kg capacity hydro Extractor Machine detailed specification hosting positioning fixing testing and c ommissioning of a heavy duty industrial grade hydro extractor machine having capacity of 15 kg High speed self balancing suspended type to minimize vibration including inner basket made of heavy gauge stainless steel dynamically balanced to prevent eccentricity during high speed raotation outer drum made from stainless steel high grade epoxy coated with sutable high torque energy nefficicient elctric motgor coupled with and automatic variable frequency drive for smooth acceleraion with interlocking ton lid safety switches to prevent the machine from starting if the lid is open and cut instantly cut power brakes if opened during operation Auto timed cycle with adjustable digital timer emergency stop button and unbalance safety switch The rate quoted by the contractor shall be all inclusive and must cover foundation and fixing and casting a suitable anti vibration concrete foundation block or supply and fixing heavy duty anti vibration anchoring bolts including making necessary water connecetion and electric connection with control panel with copper wire and testing onn full load prescribed duration to balancing vibration limits noise levels moisture and proper functioning of all safety complete all as specified and directedPLEASE NOTE Make of machine STEFAB OBLIQUE FABCARE OBLIQUE LEMISON 1 Nos 90
3 Disconnecting Disassembling and other works mentioned in item description of Electric heated laundry drying tumbler machine capacity 15kg Disconnecting Disassembling taking out old hydra extractor machine and deposit to MES store yard and Supply fixing testing and commissioning of a heavy duty commercial grade front loading electric heated laundry drying Tumbler machine having capacity of 15 kg with a high grade stainless steel inner drum designed to prevent fabric snagging front loading with wide door lack machanism heating system with minimum rating of 15 kg to ensure rapid drying cycles microprocess based programble controller digital display for cycle time temp drying time and cool down with and automatic reverssal feature to prevent linen tangling overheating protectiion emergency stop button exhaust duct pressure sensor and drive belt failure detection The item shall be complete with all standard accessories internal wiring controll panel and initial maintenance safe delivery to site loding unloading shifitint ot laundry room and placing the macine in the exact designated location on a flat lavel concrete plinth and anchoring if required connection from panel with copper wire from tumbler outlet to the externakl exhaust ductwork and earthing to machine body to the maiun earth grid for electrical safety including commissioning and to check the machine function operation complete all as specified and directed PLEASE NOTE Make of machine STEFAB OBLIQUE FABCARE OBLIQUE LEMISON 1 Nos 90
4 Disconnecting Disassembling and other works mentioned in item description of automatic electricaly heated dry cleaning machine capacity 15kg Disconnecting Disassembling taking out old fully automatic electrically heated dry cleaning machine and deposit to MES store yard and Supply installation testing and commissioning of 15 kg capacity fully automatic electrically heated dry cleaning machine complete with all accessories internal piping and control system including electric heating elementys for solventy heating and drying processess high grade stainless steel for inner drum outer basket distillation still recovery housing and all components in direct contact with solvents filtration and distilation high efficiancy eco filter system along with a continuous unit for solvent recovery microprocess based programmable controller diagnostic display and manual overrides fixing of machine on to a prepared anti vibration concrete plinth of directly to the floor using heavy duty anchor bolts and anti vibration mountings to mitifate dynamic loads during high spin extraction electrical connection from the isolator to machine using proper copper wire glands and earthing plumbing work for cooling water supply solvent drain lines and compressed lines inclusive bypass valves strainers pressure gauge and connector testing lines solvent leaks testing safety interlocks and verifying heater element draw and running full dummy cycles by actual solvent wash loads to veryfie cycles times temp controls distillation efficiency and speed and conductioning on site training for the operation staff complete all as specified and directed PLEASE NOTE Make of machine STEFAB OBLIQUE FABCARE OBLIQUE LEMISON 1 Nos 90
5 Supply laying and testing cable XLPE insulated screend PVC bedded galvanised steel strip or wire armoured electric power cables Heavy duty 1100 V and other related work mentioned in item description Supply laying and testing cable XLPE insulated screend PVC bedded galvanised steel strip or wire armoured electric power cables Heavy duty 1100 V grade with stranded aluminium conductor of size 70 sqmm x 3 point 5 Core laid in trenches or passing through pipe including taking down of existing cable service connection of any type or size and removing from site to MES store for reuse if serviceable or for credit all as specified and directed and directed by Engr In Charge 52 RM 90
6 Exacavation in trenches not exceeding 1point5m width and not exceeding 1point5m depth and getting out for laying of pipe etc in any type of soil complete Exacavation in trenches not exceeding 1point5m width and not exceeding 1point5m depth and getting out for laying of pipe etc in any type of soil complete all as specified and directed 312 Cuft 90
7 Returning filling of excavated soil including spreading levelling watering and well ramming in layers not exceeding 25cm in soft loose soil complete all as specified and directed Returning filling of excavated soil including spreading levelling watering and well ramming in layers not exceeding 25cm in soft loose soil complete all as specified and directed 198 Cuft 90
8 Removing of surplus soil to a distance n exc 50m and depositing where directed at a level n exc 1point5m above the strating point in soft loose soil complete all as specified and directed Removing of surplus soil to a distance n exc 50m and depositing where directed at a level n exc 1point5m above the strating point in soft loose soil complete all as specified and directed 133 Cuft 90
9 Sand filling in trenches with clean dry unwashed sand free from sharp particles gently punning around the cables complete Sand filling in trenches with clean dry unwashed sand free from sharp particles gently punning around the cables complete 94 Cum 90
10 Brick old size sub class B laid in trenches with width wise along the alignment of the cable as protection complete Brick old size sub class B laid in trenches with width wise along the alignment of the cable as protection complete 290 Nos 90
11 Supply and Fixing tube light grade galvanised with all fitting laid in trenches fixed to wall and floor of 40 mm dia for cable protection complete all as specified and directed Supply and Fixing tube light grade galvanised with all fitting laid in trenches fixed to wall and floor of 40 mm dia for cable protection complete all as specified and directed 6 RM 90
12 Supply fixing testing and commissioning of factory made LT panel board and other works as mentioned in item description Supply fixing testing and commissioning of factory made LT panel board made out of CRCA sheet 3 point 15mm thick outdoor type totally enclosed with front opening hinged doors with canopy sloped top projected weather and water proof as per IS 8623 with necessary locking arrangement all as specified and directed including painting with two coats of synthetic enamel paint over a coat of red oxide primer internal electric connections as required suitable to accommodate the following 1 MCCB 250 Amp TPN 01 No I C ii MCCB 63A 04 Nos O G Al bus bar 400Amp indication lamps 03 Ammeter Voltmeter complete all as specified and directed 1 Each 90
13 S and F tube medium grade galvanised with all fitting laid in trenches of 25 mm dia complete all as specified and directed S and F tube medium grade galvanised with all fitting laid in trenches of 25 mm dia complete all as specified and directed 12 RM 90
14 S and F in repair 25 mm bore gun metal gate valve heavy duty confirming to IS 778 with iron wheel head screwed both ends for iron pipe complete including taking out old un serviceable S and F in repair 25 mm bore gun metal gate valve heavy duty confirming to IS 778 with iron wheel head screwed both ends for iron pipe complete including taking out old un serviceable one all as specified and directed 2 Each 90
15 M and L sub main wiring PVC insulated unsheathed FRLSH confirming to IS 694 ratio 2010 and other related work as mentioned in item Description M and L sub main wiring PVC insulated unsheathed FRLSH confirming to IS 694 2010 multi stranded copper conductor ISI marked with valid CML No cable 1100 Volt grade of 2 run 10 sqmm for phase and neutral and one run for earth wire including concealed conduit medium grade ISI marked with valid CML No not less than 25 mm dia confirming to IS 14930 Part 1 2001 with all fitting and fixing accessories and connected up to DB complete all as specified and directed NOTE i Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit and the quoted rates shall be deemed to be inclusive for cutting chases in wall pillars columns etc of any description for concealing the conduits to required depth and making good the disturbed surface in cement mortar 1 4 including finishing the surface with putty to match with the existing surface 70 RM 90
16 S and F MCB DB sheet metal enclosures double door SPN 04 way with bus bar 240 volts 2 in 1 shutter type METAL DOOR type with blanking plates where required and IP 43 degree protection S and F MCB DB sheet metal enclosures double door SPN 04 way with bus bar 240 volts 2 in 1 shutter type METAL DOOR type with blanking plates where required and IP 43 degree protection complete all as specified and directed 4 Each 90
17 Supply and fixing 415V 10KA B curve TPN four pole 40 to 100A with connection testing and commissioning complete all as specified and directed Supply and fixing 415V 10KA B curve TPN four pole 40 to 100A with connection testing and commissioning complete all as specified and directed 4 Each 90

Similar tenders

India Public Procurement Intelligence

Frequently asked questions

The last date to submit a bid for BoQ 1234, AutomationTestCategory_DoNotUse, Qty: 1182 is 30 Nov 2026. Submit before this date to be considered.

This tender has been issued by CONTROLLER GENERAL OF DEFENCE ACCOUNTS in India.

The tender value is not disclosed; please refer to the tender document. The EMD / bid security is ₹194000.

This tender is Self Financed

The tender is classified under the following CPV code(s): 38912000 - Automated swab test kits, 38570000 - Regulating and controlling instruments and apparatus, 38911000 - Manual swab test kits.

The tender notice and related documents are listed in the Documents section above. Select a document to view or download it. Please log in or register to access the documents. If you cannot find additional documents in the Documents section, please log in to your account and Send Document Request from your account section.

The TendersOnTime reference is 152814010. The purchaser document reference is available after login.

See the Similar Tenders section on this page or browse other tenders from India.

This tender falls under Technology and Equipment in India. Suppliers in these sectors can track similar India tenders using CPV-based alerts.