Procurement Summary
Country: Germany
Summary: Tunnel Connection to the Heart Center; House 60A - Connection to Driverless Transport System (Awt System)
Deadline: 21 Oct 2026
Posting Date: 06 Oct 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 150485367
Document Ref. No.: 2023-005-464
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_detailsLogin to see details
Tender Details
The heart center (house 61) to be built on the UMMD site is to be upgraded for AWT operation. To connect the heart center (house 61) from the existing house H60a via a tunnel that has yet to be built. The tunnel is for both bed transport also intended for the AWT system. A fire protection door with approval for rail-bound conveyor technology must be implemented within the connecting tunnel. AWT transport should be equipped with two lanes as far as possible. In the first section The existing vehicles of the AWT system from House 60 are to connect to House 61 via the tunnel. All goods that are currently transported in house 60 with the AWT system should also reach house 60. These transports are bidirectional. Since the tunnel is also for If the facility is to be used for emergency patients, “priority switching” must be provided for the elevators. As soon as there is a registration for an emergency transport, the AWT system must either move to waiting positions or end the elevator journey that has begun and the elevator then release. The corresponding signal comes from the elevator control and is connected to the AGV via the elevator interface. Outside the fire protection door, electrically driven swing doors also pass through the AWT system. The swing doors must have an interface to exchange data with the AGV. In this area, too, emergency transport has priority and the AWT system must occupy/drive to waiting spaces on both sides of the doors. For technical reasons a AWT transport with an elevator that has begun cannot be canceled and must be completed. An interface for registering emergency transports must be set up/maintained by the AWT supplier. The fire gate is “permanently” open programmed and only closes when a fire alarm signal or smoke detection is triggered. In the area of the elevators in the direction of house 60 there will be a hollow floor on site with a load...
Type of procedure: University Hospital Magdeburg A.ö.R. Leipziger Straße 44 39120 Magdeburg
Documents
Tender Notice