Procurement Summary
Country: Oman
Summary: Triple Liquid Water Isotope Analyzer, Oty: 1
Deadline: 05 Jan 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 132701696
Document Ref. No.: 1234/25/0240
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
Triple Liquid Water Isotope Analyzer, Oty: 1 Category : Equipment Last Date Of Submission : 05/01/2026
SQU Product Code : false Description : Triple Liquid Water Isotope Analyzer Quantity : 1 Remark : Triple Liquid Water Isotope AnalyzerTriple Isotopic Water AnalyzerTripe Isotopic Water Analyzer for isotopic water measurements (liquid water and water vapor) reporting all major isotopologues (H2O, H2HO, H217O, H218O).SpecificationHigh Performance Modeδ2H: 0.2‰ (200 per meg), δ17O: 0.03‰ (30 per meg), 17O-excess: 20 per megδ18O: 0.03‰ (30 per meg), Typical: High Performance Mode, δ2H: 0.15‰ (100 per meg), δ17O: 0.02‰ (20 per meg)17O-excess: 15 per meg, δ18O: 0.02‰ (20 per meg)High Throughput Mode, δ2H: 0.4‰ (500 per meg), δ17O: 0.1‰ (100 per meg), δ18O: 0.1‰ (100 per meg)Typical: High Throughput Mode, δ2H: 0.3‰ (300 per meg), δ17O: 0.08‰ (80 per meg), δ18O: 0.08‰ (80 per meg)Throughput: Over 800 injections per day (with Autoinjector), Sample volume: 1 µL per injection, Salinity: less than 4%, Temperatures: Sample temperature: 5 to 50 °C, Operating temperature: 0 to 45 °C Water Vapor, Precision (12, 000 ppm, 10 sec / 100 sec):, δ2H: 0.5‰ / 0.2‰, δ17O: 0.15‰, 0.05‰ (IWA-45EP only), δ18O: 0.15‰ / 0.05‰, [H2O]: 0.2% / 0.07%Measurement Rates: Up to 2 Hz (optional external pump required for 1/e flow time 6 seconds), maximum drift (15 min average at stp over 24 hrs):, δ2h: 0.8‰, δ17o: 0.2‰, δ18o: 0.2‰, [h2o]: 0.1%measurement range:, 4, 000 to 60, 000 ppm (non-condensing)operating range: up to 70, 000 ppm sampling conditions:, sample temperature: -20 – 50 °c operating temperature: 0 – 45 °cambient humidity: 99% rh (non-condensing)terms and conditions:the quotation must include the following details:1. warranty period.2. delivery period.3. price list for the major spare parts.4. cost of maintenance visit per day after the warranty period expires.5. submission a copy of an operation & service manuals at the installation time.6. back up/spare parts support up to the 10th year.7. details of any pre-installation requirements (attached with...
Documents
Tender Notice