Transformer Oil Oil, Amt: 480000.00 Tender in Kazakhstan - 137614676

The MUNICIPAL STATE ENTERPRISE WITH THE RIGHT OF ECONOMIC MANAGEMENT "TALDYKORGANTEPLOSERVIS" OF THE STATE INSTITUTION "DEPARTMENT OF HOUSING AND COMMUNAL SERVICES OF THE CITY OF TALDYKORGAN" has issued a Tender notice for the procurement of a Transformer Oil Oil, Amt: 480000.00 in the Kazakhstan. This Tender notice was published on 12 Mar 2026 and is scheduled to close on 13 Mar 2026, with an estimated Tender value of KZT 480000.00. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 137614676, while the tender notice number is 16542500-1 and Registering on the platform.

Expired Tender

Procurement Summary

Country: Kazakhstan

Summary: Transformer Oil Oil, Amt: 480000.00

Deadline: 13 Mar 2026

Posting Date: 12 Mar 2026

Other Information

Notice Type: Tender

TOT Ref.No.: 137614676

Document Ref. No.: 16542500-1

Competition: ICB

Financier: Self Financed

Purchaser Ownership: Public

Tender Value: KZT 480000.00

Purchaser's Detail

Name: Login to see tender_details

Address: Login to see tender_details

Email: Login to see tender_detailsLogin to see details

Tender Details

Lots: Transformer oil - Oil T-1500U (TU 38.401-58-107-97) is produced from sulfurous paraffinic oils using selective purification and hydrogenation processes. Contains the additive ionol. Has improved stability against oxidation, has low content of sulfur compounds, low dielectric loss tangent. Recommended for use in electrical equipment with voltages up to 500 kV and higher. Transformer oils are used for filling power and measuring transformers, reactor equipment, as well as oil circuit breakers; in the latter devices, oils perform the functions of an arc-extinguishing medium II-standard. The electrical insulating properties of oil are determined mainly by the dielectric loss tangent. The dielectric strength of transformer oils is mainly determined by the presence of fibers and water, so mechanical impurities and water in the oils must be completely absent. A low pour point of oils (-45 °C and below) is necessary to preserve them mobility at low temperatures. To ensure effective heat removal, transformer oils must have the lowest viscosity at a flash point of at least 95, 125, 135 and 150 °C for different brands. Indicators T-1500U Kinematic viscosity, mm2/s, at a temperature of 40 °C: - 11, Kinematic viscosity, mm2/s, at a temperature of - 30 °C: - 1300, Acid number, mg KOH/g, no more than: 0.01, Flash point, °C in a closed crucible, not lower: - 135, Pour point, °C, not ...

Documents

 Tender Notice


Request Demo
GiZ Tenders India

Procurement Documents for Kazakhstan

Access a comprehensive library of standard procurement documents specific to Kazakhstan. Here, you'll find all the essential forms, guidelines, and templates required for tender applications and submissions in Kazakhstan

Explore Procurement Documents for Kazakhstan


Want To Bid in This Tender?

Get Local Agent Support in Kazakhstan and 60 More Countries.

View All The Services


View Tenders By


Publish Tenders


Have Any Dispute With The Purchaser?