Procurement Summary
Country : Zambia
Summary : Supply, Installation and Commissioning of Solar Photovoltaic Systems and Batteries
Deadline : 05 Apr 2023
Other Information
Notice Type : Tender
TOT Ref.No.: 80715683
Document Ref. No. : BEL22004_10018
Financier : Other Funding Agencies
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Tenders are invited for Supply, Installation and Commissioning of Solar Photovoltaic Systems and Batteries at Lake Tanganyika Research Unit Mpulungu-Zambia
Installation of the solar panel
• Made from crystalline silicon cells (mono or poly);
• Thin film modules are not allowed;
• Glass assembly (min. 3.2 mm) rear side tedlar or glass (bi-glass modules accepted and
encouraged);
• Consists of 60 or 72 6" cells connected in series;
• Positive power tolerance;
The results of the flash tests should be kept available and can be requested upon delivery
of the modules;
• Delivered pre-wired with junction boxes containing a minimum of 3 bypass diodes, PVspecific plug-in connectors, junction boxes that have never had a proven serial fault ;
• Anodised aluminium frame;
• Max system voltage greater than or equal to 1000 Vdc;
• Class II in accordance with NF EN 61140;
• Individual labelling including : manufacturer, model, place of manufacture, electrical
characteristics, serial number;
• Manufacturer affiliated to a PV module recycling organisation (e.g. PV Cycle);
• Conformity to IEC 61215 and IEC 61730-1-2 and to the CE directives, certified by an
approved laboratory;
• 90% power guarantee at 10 years and 80% at 25 years;
• Product warranty of 10 years or more;
• Anti-theft bolts to protect each solar panel.
2.2 PV off-hook connectors
• MC4 PV plug-in connectors, pre-fitted on components and/or to be supplied by the
Contractor, male-female assembly to be provided systematically:
o Pre-wired on module cable
o At the end of the chain cables
o At the input of the DC-PV boxes
• Minimum characteristics to be respected:
o Rated voltage 1, 000 Vdc minimum
o Class II
o Contact resistance 0.5 mOhms maximum
o IP 65 minimum
o Complies with the NF EN 50521 standard
o Supply of metal and plastic parts
Documents
Tender Notice