Procurement Summary
Country: Germany
Summary: Revitalization of Ringstrasse 60 Lot 5 Shell + Facade
Deadline: 29 May 2026
Posting Date: 29 Apr 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 140341964
Document Ref. No.: LWB_ZE-2026-0038
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
CPV Classification
45223220 - Structural shell work
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
1. Shell construction work: -Demolition of 3 light wells -75 m³ excavation of earth for -60 m³ delivery and installation of filling floor -Approx. 20 m³ in-situ/sub-concrete C 16/20, X0, unreinforced -12.5 m³ in-situ concrete C 16/20, 25 cm -Cut 8 openings in wall made of reinforced concrete, d= 26 cm three-layer panel -Enlarge 126 loggia door openings + cut out thresholds -Change and create 235 wall openings made of reinforced concrete, d= 15 cm (various sizes) -Supply 1.13 t steel beams and Install according to static requirements -216 Manufacture and deliver prefabricated reinforced concrete lintels, L= 120 - 170 cm -16 m³ subsequent closing of installation shafts -70 m brick up existing window sills, RDK 1.8 -40 close existing door openings RDK 2.0 -200 m masonry connection anchors 4 pieces/m -Produce 165 core drillings DN 100 - 200, ceilings and walls -290 additional anchors for weather shell securing -Supply and installation of 2 slide-in stairs 130/70 cm 2. Concrete renovation: -5, 800 m² concrete surface examine -2, 800 m² contamination clean with low-pressure water jets -63 m² removal of damaged concrete, pre-treat reinforcement bars + reprofiling 3. Sealing loggia panels: -126 times check underground hollow layers -200 m² underground pre-treatment + Primer concrete, screed, MW, plaster + filling of defects -435 m Preparation of gutters -126 pcs. Surface sealing including wear layer loggias -126 Preparation of loggia drains 4.ETICS: -Static dimensioning -Approx. Remove 5, 000 m² of contaminants + Primer -120 m² plaster over unevenness -150 m attach base rail -2, 800 m² MiWo insulation, d= 140 mm + reinforcement -1, 350 m MiWo insulation panels in reveals t=6+14 cm + reinforcement -70 m² base insulation d= 60 mm -135 m² perimeter insulation d= 140 mm + Reinforcement -Cutting and adapting loggia drainage, lamps, sockets, bat openings -2, 820 m joint sealing tape, 5-12 mm -1, 860 m fabric corner protection -1, 370 m connection plaster strip -Approx. 5, 000 m²...
Documents
Tender Notice