Procurement Summary
Country: Oman
Summary: Ph-Meter, Oty: 1
Deadline: 22 Jun 2026
Posting Date: 08 Jun 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 142829631
Document Ref. No.: 7026/26/0089
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
PH-METER, Oty: 1 Category : Equipment Last Date Of Submission : 22/06/2026
SQU Product Code : EQUBIOPH-0001 Description : PH-METER Quantity : 1 Remark : pH/ORP/ISE + EC + Optical DOMultiparameter Modular Benchtop MeterRange: -2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000to 20.000 pHResolution: 0.1 pH; 0.01 pH; 0.001 pHAccuracy: ±0.1 pH; ±0.01 pH; ±0.002 pH (±1 lastsignificant digit)Temperature Compensation: Automatic ormanualmVRange: -2000.0 mV to 2000.0 mVResolution: 1 mV; 0.1 mVAccuracy: ±0.2 mV ±1 last significant digitISERange: 1 x 10-6 to 9.99 x 1010 concentrationResolution: 1; 0.1; 0.01; 0.001 concentrationAccuracy: ±0.5% (monovalent ions); ±1%(divalent ions)Calibration: Automatic, up to five-pointcalibration, seven fixed standard solutionsavailable for each measurement unit, and fiveuser defined standardsTemperature Range: -20.0 to 120.0 °C; -4.0 to248.0 °F; 253.0 to 393.0 KResolution: 0.1 °C / 0.1 °F / 0.1 KAccuracy: ±0.2 °C / ±0.4 °F / ±0.2 KRelative mV offset range: ±2000.0 mVpH Calibration Calibration points: Up to 5Type: Automatic; Semi automatic; ManualStandard buffers: Hanna and NIST - pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45Custom buffers: Up to 5Custom group: Up to 51st calibration point: Offset or Points (usersetting)Temperature User Calibration: Single point, adjustable; Isopotential point: -2.000 to 20.000pHConductivity Range: 0.000 to 9.999 μS/cm; 10.00to 99.99 μS/cm; 100.0 to 999.9 μS/cm;1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm;100.0 to 1000.0 mS/cmResolution: 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm;0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cmAccuracy: ±1 % of reading ±0.010 μS/cm, whichever is greaterCell Constant: 0.0500 to 200.00 /cmCalibration Type: automatic; manualCalibration points: SingleMultiple Calibration solutions: 84.00 μS/cm, 1.413 mS/cm, 5.000 mS/cm, 12.88 mS/cm, 80.00mS/cm, 111.8 mS/cmTemperature Compensation: Linear, natural, standard, disabledReference Temperature: Range: 5.0 to 30.0 ̊C(41.0 to 86.0 ̊CResolution: 0.1 ̊C / 0.1 ̊FTemperature Coefficient: 0.00 to 10.00%/ ̊CResistivity Range: 1.0 to 99.9...
Documents
Tender Notice