OMAN GAS COMPANY LLC has floated a tender for Gas Analysis for Norm and Mercury. The project location is Oman and the tender is closing on 29 Apr 2018. The tender notice number is OGC/RFQ/18/7700000404, while the TOT Ref Number is 22765083. Bidders can have further information about the Tender and can request the complete Tender document by Registering on the site.

Expired Tender

Procurement Summary

Country : Oman

Summary : Gas Analysis for Norm and Mercury

Deadline : 29 Apr 2018

Other Information

Notice Type : Tender

TOT Ref.No.: 22765083

Document Ref. No. : OGC/RFQ/18/7700000404

Competition : ICB

Financier : Self Financed

Purchaser Ownership : -

Tender Value : Refer Document

Purchaser's Detail

Purchaser : OMAN GAS COMPANY LLC
PO Box: 799, Postal Code: 133 Al khuwair, Muscat - Sultanate Tel: +968-2446000 Fax: +968-2446900
Oman
Email :mahmood.alwahaibi@oman-gas.com.om
URL :www.oman-gas.com.om

Tender Details

Quotation are invited for Gas Analysis for Norm and Mercury.


Scope & Application: To Determine the Total Mercury in Natural Gas Bylumex Ra-915+ Mercury Analyzer. It is Based on Flameless Atomization Andmeasuring the Absorption of the 254-Nm Resonance Radiation by Mercuryatoms Using Zeeman Correction for Background Absorption in the Purginggas Stream. Equipment: Ra-915+ Mercury Analyzer is a Potable Multifunctional Atomicabsorption Spectrophotometer with Zeeman Background Correction, Which Eliminate the Effect of Interfering Impurities. It is does Notrequire Gold Amalgam Pre Concentration and Subsequent Regenerationsteps. This Enables to Real Time Monitoring and Detection of Mercuryvapor in Natural Gas. Procedure: Once the Instrument is Stabilized, Press on Stream Button Onthe Control Panel. Before Doing the on Stream Analysis Make Sureto Change the Bridge Position in the Second Position. Check the Rl Valueof the Display, if it is below or Equal to 20 % the Equipment is Readyfor the Analysis. Connect the Tubing and Check for Base Linecorrections. Connect the Three Way Tubing-S with Sample Point. Open Thesampling Valve with Controlled Pressure. Open the Three Way Valvethrough the Filter to Make Sure the Sample was Going inside through Thefilter for Zero Mercury Check. Flow for the Analysis is 1-10l/ Min, with1-1.5bar Pressure. Once the Zero Check is Completed, Close the Valvetowards the Filter and Allow Flow the Sample in to the System directly.note the Readings Minimum Two Times to Get a Repeatable Mean Value Fromthe Display of the Equipment. Calculation & Reporting.

Kpa
C - Mercury Concentration on Display, Ng/m3
T - Temperature during Measurement, Degree Centigrade
P - Pressure, Kpa
Q - Calculation Coefficient, 2.69
For “Indoor” Measurements, T=25 °C and P=1 Bar (101.325 Kpa)
For“outside” Measurements or Technological Control, T=0 °C and P=1
Bar(101.325 Kpa).
Minimum Detection Limit is 2ng/m3. Report Results as N/m3 of Sample
Reference : Iso 6978

Documents

 Tender Notice