Procurement Summary
Country: Brazil
Summary: Formation of Price Record Minutes for the Occasional Supply of Opme(S) of the Heart Valve Type, under a Consignment System, According to Specifications and Quantities Provided for in the Terms of Reference...
Deadline: 03 Jun 2026
Posting Date: 18 May 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 141529418
Document Ref. No.: 90144/2026
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_detailsLogin to see details
Tender Details
Object: Electronic Auction - Formation of Price Registration Minutes for the occasional supply of OPME(s) of the heart valve type, under a consignment system, in accordance with the specifications and quantities provided for in the Terms of Reference (Annex I), aiming to meet to the demands of the Agamenon Magalhães Hospital. UASG Code: 926150 Notice from: 05/18/2026 from 08:00 to 17:59 Proposal Delivery: from 05/18/2026 at 08:00 BIOLOGICAL HEART VALVE PROSTHESIS, TYPE OF AORTIC VALVE, PROCEDURE FOR CONVENTIONAL SURGERY IMPLANT, MODEL WITH RING, POLYMER STRUCTURE MATERIAL, QUANTITY OF LEAFLETS 3 LEAFLETS, LEAFLET MATERIAL BOVINE/ PORCINE TISSUE, RADIOPAQUE RADIOPACITY, NO ANTICALCIFICATION TREATMENT, TYPE OF STORAGE IN ALDEHYDE SOLUTION, COMPATIBILITY WITH MAGNETIC RESONANCE YES, UP TO 3.0 T, WITH EXPOSURE TIME LIMIT, VIV POSSIBILITY (VALVE IN VALVE) NO, STERILE STERILITY, SINGLE USE Quantity: 36 BIOLOGICAL HEART VALVE PROSTHESIS, MITRAL VALVE TYPE, PROCEDURE PARAIMPLANT SURGERY MIS- MINIESTERNOTOMY/ MINITHORACOTOMY, MODEL WITH RING, POLYMER STRUCTURE MATERIAL, QUANTITY OF LEAFLETS 3 LEAFLETS, LEAFLET MATERIAL BOVINE/ PORCINE TISSUE, RADIOPAQUE RADIOPACITY, ANTICALCIFICATION TREATMENT YES, TYPE OF STORAGE IN ALDEHYDE SOLUTION, COMPATIBILITY WITH MAGNETIC RESONANCE YES, UP TO 3.0 T, WITH EXPOSURE TIME LIMIT, VIV POSSIBILITY (VALVE IN VALVE) YES, STERILE STERILITY, SINGLE USE Quantity: 36 MECHANICAL HEART VALVE PROSTHESIS, TYPE OF AORTIC VALVE, PARAIMPLANT PROCEDURE MIS SURGERY - MINISTERNOTOMY/ MINITHORACOTOMY, METAL ALLOY/ PYROLYTIC CARBON MATERIAL, QUANTITY OF LEAFLETS 2 LEAFLETS, RADIOPAQUE RADIOPACITY, TYPE OF DRY STORAGE, COMPATIBILITY WITH RESONANCE MAGNETIC YES, UP TO 3.0 T, WITH EXPOSURE TIME LIMIT, LOW PROSTHESIS PROFILE, OPEN PIVOT GUARDS CHARACTERISTICS, STERILE STERILITY, SINGLE USE When...
Documents
Tender Notice