Procurement Summary
Country: Germany
Summary: Federal Environment Agency - Dahlem Triangle - Emergency Network System According to Din 18 382 According to Din 18 382 - 78/2026
Deadline: 29 May 2026
Posting Date: 28 Apr 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 140279796
Document Ref. No.: 87/2026
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
CPV Classification
45310000 - Electrical installation work
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_detailsLogin to see details
Tender Details
Emergency power system according to DIN 18 382 according to DIN 18 382 - KKE 4403 General rules Construction work ATV DIN 18299 VOB/C Electrical, safety and information technology systems ATV DIN 18382 VOB/C Concrete work ATV DIN 18331 VOB/C Steel construction work ATV DIN 18335 VOB/C Metal construction work ATV DIN 18360 VOB/C Ventilation systems ATV DIN 18379 VOB/C Roof covering and roof sealing work ATV DIN 18338 VOB/C Sealing work ATV DIN 18336 VOB/C Plumbing work ATV DIN 18339 VOB/C • Emergency power system 1x 770 kVA for Exclusive operation with diesel-quality heating oil for installation in a prefabricated concrete station, which is also part of the scope of services, with external dimensions of 12.8 m long x 5.0 m wide x 3.5 m high for construction on site Strip foundations/frost apron as well as the adjacent free-standing steel chimney system with measuring platform and head platform, height 15 meters, including anchor basket for erection on the chimney foundation provided by the customer. The delivery of the The replacement power system must be installed in transportable assemblies (NEA module with front-mounted cooler on base frame, storage tank with assembly, piping and cabling on site. • Concrete station, on site made of prefabricated concrete parts with a maximum individual weight of 15 tons assembled, consisting of the unit room for setting up the NEA module with front-mounted cooler, day tank with at least 0.7 m³ usable volume, with collecting pan, heating oil pump system 2x 100%, exhaust system with soot filter and exhaust silencer, supply air and Exhaust air openings with louvre flaps and sound backdrops, control/switching system and from the tank room, essentially for setting up the storage tank with at least 6.5 m³ usable volume. • Equipping the aggregate room and the tank room with steel room linings with an upstand of at least 10 cm on all sides to create AwSV-compliant collecting spaces. • Integration into central building management technolog...
Documents
Tender Notice