Login
Register
Complete Your Profile
Change Password
Request a Password Reset
Download Documents
Download Documents
Get Help to Participate in This Tender
Our team will contact you shortly.
Your activation form is pending.
Please submit it to start receiving email alerts.
Submit NowChange Password
For better security, update the account password.
The PROGRAMME DES NATIONS UNIES POUR LE DÉVELOPPEMENT (UNDP) has issued a Tender notice for the procurement of a Electrical installation works according to the specifications in Appendix 1 in Kiosks Unique Provincials five pilot provinces. in the Burundi. This Tender notice was published on 17 Oct 2015 and is scheduled to close on 27 Oct 2015, with an estimated Tender value of Refer Document. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 4037805, while the tender notice number is 26031, RFQ GUP ELEC 2015 and Registering on the platform.
Procurement Summary
Country: Burundi
Summary: Electrical installation works according to the specifications in Appendix 1 in Kiosks Unique Provincials five pilot provinces.
Deadline: 27 Oct 2015
Posting Date: 17 Oct 2015
Other Information
Notice Type: Tender
TOT Ref.No.: 4037805
Document Ref. No.: 26031, RFQ GUP ELEC 2015
Competition: ICB
Financier: United Nations Secretariat
Purchaser Ownership: -
Tender Value: Refer Document
CPV Classification
45311000 - Electrical wiring and fitting workPurchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_detailsLogin to see details
Tender Details
Quotations for Electrical installation works according to the specifications in Appendix 1 in Kiosks Unique Provincials five pilot provinces.
Technical specifications - GUP Gitega
Installing compact fluorescent lamps 18W maximum power C M: Pce
Integrated LED ceiling installation (3x4W)
Dimensions: Ø 352 x H 78 mm.
C M: Pce
Lighting installation Centure 2 for surface mounting
T8 Fluorescent tube not included
Contemporary optical design L1
Equipped; electronic ballast (HF) UGR22
C M: Pce
Fluorescent Recessed luminaire installation TBS 165
C M: Pce
Typical installation trunking Linolite polycarbonate diffuser wall sconce S19Eo
L445xl Dimensions 64mm x D 90mm
Colours: Blanx IP 24-IK07
C M: Pce
Waterproof strip installation T8
Use: local wet atmosphere. Injected polycarbonate body self-extinguishing. Fully wired. Polycarbonate diffuser. Electronic Ballast HFW / T8. Power supply: 220/240 V - 50/60 Hz IP66 - IK08.. Class 1. (...)
C M: Pce
Installation of Single Wall Switches IPX2 Mechanism protected against direct contact. 250 V voltage
C M: Pce
IP 2X mechanisms protected against direct contact. Voltage: 250 V ~. Delivered open terminals. Colours: White.
C M: Pce
Installing electrical outlets, current: 16A voltage: 250 V. For installation in flush-mounting box, frame projection workstation kit, floor box, column block, block nurse, office and chute block. Ref. : 357715
C M: Pce
Distribution board installation: Fixed 19-inch box with side ventilation louvres. Amounts 19-inch galvanized depth adjustable (4 positions) and precut for the passage of cables. Removable bottom and front door reversible opening to more than 180 °. Safety glass with lock. IP20 protection grade
C M: Pce
Installing Plexo weatherproof enclosures 12 modules / row: Self-extinguishing: glow wire 750 ° C IP 65 IK 09. Class II. Total reversibility door and cabinet. Rail 2 positions for modular products. Distance between rails: 150 mm. Lockable door handle. Sealable cap and bib
C M: Pce
Installing dual phone jack: Biplite for 2 different lines on the same contactor
C M: Mosaic Pce television sockets Installation
Fast connection without tools. Colours: White.
C M: Pce Earth spike Installation
For the safety of electrical installations. Grounding essential elements of your installations: pipes inside (heating, gas, water, air and table) and metallic body (devices (...)
C M: Pce molded material Box Installation IP 40 - IK 04. Supplied without terminal. Snap cap can be screwed. Base comprising a rail which receives the strips 10 to separate terminals. Dimensions: 100 x 80 x 36 mm. Equipment: 6/10/16 mm². Track Length: 84 mm
C M: Pce ionised smoke detector installation: Device for use in a tertiary environment, ERP, etc. with networking on DAD cabinet. Ivory colored ABS terpolymer. High performance analysis room with photocell and light source. Power supply: DC 16-28 V. Consumption (under 24V) 130 uA in standby and 28mA in alarm. Dimensions: Ø 102 x 46 mm thickness
C M: Pce heat detector installation: light diffuser visual diffuser to alert in case of fire alarm, the deaf and hard about the need to evacuate lieux.Conformes with NF EN, CE and CPD NF SSI. Fixing surface or flush mounted. IP 40 - IK 07
C M: Pce red manual release Installation: Complies with the NF EN, CE certified DPC and NF SSI. Triggered by pressure in the center of the membrane. Reset with special key provided with the product. Fixing surface or flush mounted. IP 40 - IK 07. Class II.
C M: Pce Installing audible fire alarm: Surface mounting. Red Flash. Sound: 90 dB at 2 m (Class B). IP42 - IK07. Product Standard: Complies with EN 54-3, NF S 32-001 and CE DPC and NF SSI.
C M: Pce electrical cables VOB 1.5 mm2 Installation: Hard wire HO7 VU (solid round copper) PVC insulating sheath. Uses: residential premises of circuits led arises under or in wand. Wiring and wiring tables and equipment;
C M: ml to electrical cables VOB 2.5 mm2 Installation: Hard wire HO7 VU (solid round copper) PVC insulating sheath. Uses: residential premises of circuits led arises under or in wand. Wiring and wiring tables and equipment; C M: the installation of telephone cables ml 0.6mm: PVC insulation. Assembly in pairs. Tape to maintain the assembled cable. Polyester coated aluminum screen. Nylon thread for tearing of the sheath. PVC jacket. Uses: private telephony systems installed outside buildings. Laying buried permitted. Current weak links of general applications requiring drivers assembled in pairs. Product Standard: Marking: according to standard NFC 93-529. CM: At ml
Technical specifications - GUP Ngozi
Installing compact fluorescent lamps 18W maximum power C M: Pce
Integrated LED ceiling installation (3x4W)
Dimensions: Ø 352 x H 78 mm.
C M: Pce
Lighting installation Centure 2 for surface mounting
T8 Fluorescent tube not included
Contemporary optical design L1
Equipped; electronic ballast (HF) UGR22
C M: Pce
Fluorescent Recessed luminaire installation TBS 165
C M: Pce
Typical installation trunking Linolite polycarbonate diffuser wall sconce S19Eo
L445xl Dimensions 64mm x D 90mm
Colours: Blanx IP 24-IK07
C M: Pce
Waterproof strip installation T8
Use: local wet atmosphere. Injected polycarbonate body self-extinguishing. Fully wired. Polycarbonate diffuser. Electronic Ballast HFW / T8. Power supply: 220/240 V - 50/60 Hz IP66 - IK08.. Class 1. (...)
C M: Pce
Installation of Single Wall Switches IPX2 Mechanism protected against direct contact. 250 V voltage
C M: Pce
IP 2X mechanisms protected against direct contact. Voltage: 250 V ~. Delivered open terminals. Colours: White.
C M: Pce
Installing electrical outlets, current: 16A voltage: 250 V. For installation in flush-mounting box, frame projection workstation kit, floor box, column block, block nurse, office and chute block. Ref. : 357715
C M: Pce
Distribution board installation: Fixed 19-inch box with side ventilation louvres. Amounts 19-inch galvanized depth adjustable (4 positions) and precut for the passage of cables. Removable bottom and front door reversible opening to more than 180 °. Safety glass with lock. IP20 protection grade
C M: Pce
Installing Plexo weatherproof enclosures 12 modules / row: Self-extinguishing: glow wire 750 ° C IP 65 IK 09. Class II. Total reversibility door and cabinet. Rail 2 positions for modular products. Distance between rails: 150 mm. Lockable door handle. Sealable cap and bib
C M: Pce
Installing dual phone jack: Biplite for 2 different lines on the same contactor
C M: Mosaic Pce television sockets Installation
Fast connection without tools. Colours: White.
C M: Pce Earth spike Installation
For the safety of electrical installations. Grounding essential elements of your installations: pipes inside (heating, gas, water, air and table) and metallic body (devices (...)
C M: Pce molded material Box Installation IP 40 - IK 04. Supplied without terminal. Snap cap can be screwed. Base comprising a rail which receives the strips 10 to separate terminals. Dimensions: 100 x 80 x 36 mm. Equipment: 6/10/16 mm². Track Length: 84 mm
C M: Pce ionised smoke detector installation: Device for use in a tertiary environment, ERP, etc. with networking on DAD cabinet. Ivory colored ABS terpolymer. High performance analysis room with photocell and light source. Power supply: DC 16-28 V. Consumption (under 24V) 130 uA in standby and 28mA in alarm. Dimensions: Ø 102 x 46 mm thickness
C M: Pce heat detector installation: light diffuser visual diffuser to alert in case of fire alarm, the deaf and hard about the need to evacuate lieux.Conformes with NF EN, CE and CPD NF SSI. Fixing surface or flush mounted. IP 40 - IK 07
C M: Pce red manual release Installation: Complies with the NF EN, CE certified DPC and NF SSI. Triggered by pressure in the center of the membrane. Reset with special key provided with the product. Fixing surface or flush mounted. IP 40 - IK 07. Class II.
C M: Pce Installing audible fire alarm: Surface mounting. Red Flash. Sound: 90 dB at 2 m (Class B). IP42 - IK07. Product Standard: Complies with EN 54-3, NF S 32-001 and CE DPC and NF SSI.
C M: Pce electrical cables VOB 1.5 mm2 Installation: Hard wire HO7 VU (solid round copper) PVC insulating sheath. Uses: residential premises of circuits led arises under or in wand. Wiring and wiring tables and equipment;
C M: ml to electrical cables VOB 2.5 mm2 Installation: Hard wire HO7 VU (solid round copper) PVC insulating sheath. Uses: residential premises of circuits led arises under or in wand. Wiring and wiring tables and equipment; C M: the installation of telephone cables ml 0.6mm: PVC insulation. Assembly in pairs. Tape to maintain the assembled cable. Polyester coated aluminum screen. Nylon thread for tearing of the sheath. PVC jacket. Uses: private telephony systems installed outside buildings. Laying buried permitted. Current weak links of general applications requiring drivers assembled in pairs. Product Standard: Marking: according to standard NFC 93-529. CM: At ml
Technical specifications - GUP Mwaro Installing compact fluorescent lamps 18W maximum power CM: Pce
1. LED ceiling installation included (3x4W)
Dimensions: Ø 352 x H 78 mm.
C M: Pce
2. Installing Lighting Centure 2 for surface mounting
T8 Fluorescent tube not included
Contemporary optical design L1
Equipped; electronic ballast (HF) UGR22
C M: Pce
3. Fluorescent Recessed luminaire installation TBS 165
C M: Pce
4. Installation strips kind Linolite polycarbonate diffuser wall sconce S19Eo
L445xl Dimensions 64mm x D 90mm
Colours: Blanx IP 24-IK07
C M: Pce
5. Install waterproof strip T8
Use: local wet atmosphere. Injected polycarbonate body self-extinguishing. Fully wired. Polycarbonate diffuser. Electronic Ballast HFW / T8. Power supply: 220/240 V - 50/60 Hz IP66 - IK08.. Class 1. (...)
C M: Pce
6. Installation of Single Wall Switches IPX2 Mechanism protected against direct contact. 250 V voltage
C M: Pce
7. Mechanisms IP 2X protected against direct contact. Voltage: 250 V ~. Delivered open terminals. Colours: White.
C M: Pce
8. Installation of power outlets, current: 16A voltage: 250 V. For installation in flush-mounting box, protruding part, workstation kit, floor box, column block, block nurse, office and chute block. Ref. : 357715
C M: Pce
9. distribution board installation: fixed box 19 inches with side ventilation louvres. Amounts 19-inch galvanized depth adjustable (4 positions) and precut for the passage of cables. Removable bottom and front door reversible opening to more than 180 °. Safety glass with lock. IP20 protection grade
C M: Pce
10. Installing Plexo weatherproof enclosures 12 modules / row: Self-extinguishing: glow wire 750 ° C IP 65 IK 09. Class II. Total reversibility door and cabinet. Rail 2 positions for modular products. Distance between rails: 150 mm. Lockable door handle. Sealable cap and bib
C M: Pce
11. Installing double Telephone connection: Biplite for 2 different lines on the same contactor
C M: Pce
12. Mosaic sockets TV installation
Fast connection without tools. Colours: White.
C M: Pce
13. Earth spike Installation
For the safety of electrical installations. Grounding essential elements of your installations: pipes inside (heating, gas, water, air and table) and metallic body (devices (...)
C M: Pce
14. Installing molded material Box IP 40 - IK 04. Supplied without terminal. Snap cap can be screwed. Base comprising a rail which receives the strips 10 to separate terminals. Dimensions: 100 x 80 x 36 mm. Equipment: 6/10/16 mm². Track Length: 84 mm
C M: Pce
15. ionised smoke detector installation: Device for use in a tertiary environment, ERP, etc. with networking on DAD cabinet. Ivory colored ABS terpolymer. High performance analysis room with photocell and light source. Power supply: DC 16-28 V. Consumption (under 24V) 130 uA in standby and 28mA in alarm. Dimensions: Ø 102 x 46 mm thickness
C M: Pce
16. Heat Detector Installation: visual light diffuser Diffuser to alert in case of fire alarm, the deaf and hard about the need to evacuate lieux.Conformes with NF EN, CE certified DPC and NF SSI . Fixing surface or flush mounted. IP 40 - IK 07
C M: Pce
17. Installing Red manual release: Complies with the NF EN, CE certified DPC and NF SSI. Triggered by pressure in the center of the membrane. Reset with special key provided with the product. Fixing surface or flush mounted. IP 40 - IK 07. Class II.
C M: Pce
18. Installation of fire alarm sound: Surface mounting. Red Flash. Sound: 90 dB at 2 m (Class B). IP42 - IK07. Product Standard: Complies with EN 54-3, NF S 32-001 and CE DPC and NF SSI.
C M: Pce
19. Installation of electric cables VOB 1.5 mm2 Rigid cable HO7 VU (solid round copper) PVC insulating sheath. Uses: residential premises of circuits led arises under or in wand. Wiring and wiring tables and equipment;
CM: At ml
20. Installation of electric cables VOB 2.5 mm2 Rigid cable HO7 VU (solid round copper) PVC insulating sheath. Uses: residential premises of circuits led arises under or in wand. Wiring and wiring tables and equipment; CM: At ml
21. Installation of telephone cables 0.6mm: PVC insulation. Assembly in pairs. Tape to maintain the assembled cable. Polyester coated aluminum screen. Nylon thread for tearing of the sheath. PVC jacket. Uses: private telephony systems installed outside buildings. Laying buried permitted. Current weak links of general applications requiring drivers assembled in pairs. Product Standard: Marking: according to standard NFC 93-529. CM: At ml
Technical specifications - GUP MUYINGA
Compact fluorescent lamps installation maximum power of 18W CM: Pce
1. LED ceiling installation included (3x4W)
Dimensions: Ø 352 x H 78 mm.
C M: Pce
2. Installing Lighting Centure 2 for surface mounting
T8 Fluorescent tube not included
Contemporary optical design L1
Equipped; electronic ballast (HF) UGR22
C M: Pce
3. Fluorescent Recessed luminaire installation TBS 165
C M: Pce
4. Installation strips kind Linolite polycarbonate diffuser wall sconce S19Eo
L445xl Dimensions 64mm x D 90mm
Colours: Blanx IP 24-IK07
C M: Pce
5. Install waterproof strip T8
Use: local wet atmosphere. Injected polycarbonate body self-extinguishing. Fully wired. Polycarbonate diffuser. Electronic Ballast HFW / T8. Power supply: 220/240 V - 50/60 Hz IP66 - IK08.. Class 1. (...)
C M: Pce
6. Installation of Single Wall Switches IPX2 Mechanism protected against direct contact. 250 V voltage
C M: Pce
7. Mechanisms IP 2X protected against direct contact. Voltage: 250 V ~. Delivered open terminals. Colours: White.
C M: Pce
8. Installation of power outlets, current: 16A voltage: 250 V. For installation in flush-mounting box, protruding part, workstation kit, floor box, column block, block nurse, office and chute block. Ref. : 357715
C M: Pce
9. distribution board installation: fixed box 19 inches with side ventilation louvres. Amounts 19-inch galvanized depth adjustable (4 positions) and precut for the passage of cables. Removable bottom and front door reversible opening to more than 180 °. Safety glass with lock. IP20 protection grade
C M: Pce
10. Installing Plexo weatherproof enclosures 12 modules / row: Self-extinguishing: glow wire 750 ° C IP 65 IK 09. Class II. Total reversibility door and cabinet. Rail 2 positions for modular products. Distance between rails: 150 mm. Lockable door handle. Sealable cap and bib
C M: Pce
11. Installing double Telephone connection: Biplite for 2 different lines on the same contactor
C M: Pce
12. Mosaic sockets TV installation
Fast connection without tools. Colours: White.
C M: Pce
13. Earth spike Installation
For the safety of electrical installations. Grounding essential elements of your installations: pipes inside (heating, gas, water, air and table) and metallic body (devices (...)
C M: Pce
14. Installing molded material Box IP 40 - IK 04. Supplied without terminal. Snap cap can be screwed. Base comprising a rail which receives the strips 10 to separate terminals. Dimensions: 100 x 80 x 36 mm. Equipment: 6/10/16 mm². Track Length: 84 mm
C M: Pce
15. ionised smoke detector installation: Device for use in a tertiary environment, ERP, etc. with networking on DAD cabinet. Ivory colored ABS terpolymer. High performance analysis room with photocell and light source. Power supply: DC 16-28 V. Consumption (under 24V) 130 uA in standby and 28mA in alarm. Dimensions: Ø 102 x 46 mm thickness
C M: Pce
16. Heat Detector Installation: visual light diffuser Diffuser to alert in case of fire alarm, the deaf and hard about the need to evacuate lieux.Conformes with NF EN, CE certified DPC and NF SSI . Fixing surface or flush mounted. IP 40 - IK 07
C M: Pce
17. Installing Red manual release: Complies with the NF EN, CE certified DPC and NF SSI. Triggered by pressure in the center of the membrane. Reset with special key provided with the product. Fixing surface or flush mounted. IP 40 - IK 07. Class II.
C M: Pce
18. Installation of fire alarm sound: Surface mounting. Red Flash. Sound: 90 dB at 2 m (Class B). IP42 - IK07. Product Standard: Complies with EN 54-3, NF S 32-001 and CE DPC and NF SSI.
C M: Pce
19. Installation of electric cables VOB 1.5 mm2 Rigid cable HO7 VU (solid round copper) PVC insulating sheath. Uses: residential premises of circuits led arises under or in wand. Wiring and wiring tables and equipment;
CM: At ml
20. Installation of electric cables VOB 2.5 mm2 Rigid cable HO7 VU (solid round copper) PVC insulating sheath. Uses: residential premises of circuits led arises under or in wand. Wiring and wiring tables and equipment; CM: At ml
21. Installation of telephone cables 0.6mm: PVC insulation. Assembly in pairs. Tape to maintain the assembled cable. Polyester coated aluminum screen. Nylon thread for tearing of the sheath. PVC jacket. Uses: private telephony systems installed outside buildings. Laying buried permitted. Current weak links of general applications requiring drivers assembled in pairs. Product Standard: Marking: according to standard NFC 93-529. CM: At ml
Technical specifications - GUP BURURI
Compact fluorescent lamps installation maximum power of 18W CM: Pce
1. LED ceiling installation included (3x4W)
Dimensions: Ø 352 x H 78 mm.
C M: Pce
2. Installing Lighting Centure 2 for surface mounting
T8 Fluorescent tube not included
Contemporary optical design L1
Equipped; electronic ballast (HF) UGR22
C M: Pce
3. Fluorescent Recessed luminaire installation TBS 165
C M: Pce
4. Installation strips kind Linolite polycarbonate diffuser wall sconce S19Eo
L445xl Dimensions 64mm x D 90mm
Colours: Blanx IP 24-IK07
C M: Pce
5. Install waterproof strip T8
Use: local wet atmosphere. Injected polycarbonate body self-extinguishing. Fully wired. Polycarbonate diffuser. Electronic Ballast HFW / T8. Power supply: 220/240 V - 50/60 Hz IP66 - IK08.. Class 1. (...)
C M: Pce
6. Installation of Single Wall Switches IPX2 Mechanism protected against direct contact. 250 V voltage
C M: Pce
IP 2X mechanisms protected against direct contact. Voltage: 250 V ~. Delivered open terminals. Colours: White.
C M: Pce
7. Install electrical outlets, current: 16A voltage: 250 V. For installation in flush-mounting box, protruding part, workstation kit, floor box, column block, block nurse, office and chute block. Ref. : 357715
C M: Pce
8. distribution board installation: fixed box 19 inches with side ventilation louvres. Amounts 19-inch galvanized depth adjustable (4 positions) and precut for the passage of cables. Removable bottom and front door reversible opening to more than 180 °. Safety glass with lock. IP20 protection grade
C M: Pce
9. Installing Plexo weatherproof enclosures 12 modules / row: Self-extinguishing: glow wire 750 ° C IP 65 IK 09. Class II. Total reversibility door and cabinet. Rail 2 positions for modular products. Distance between rails: 150 mm. Lockable door handle. Sealable cap and bib
C M: Pce
10. Installing double Telephone connection: Biplite for 2 different lines on the same contactor
C M: Pce
11. Mosaic sockets TV installation
Fast connection without tools. Colours: White.
C M: Pce
12. Earth spike Installation
For the safety of electrical installations. Grounding essential elements of your installations: pipes inside (heating, gas, water, air and table) and metallic body (devices (...)
C M: Pce
13. Installing molded material Box IP 40 - IK 04. Supplied without terminal. Snap cap can be screwed. Base comprising a rail which receives the strips 10 to separate terminals. Dimensions: 100 x 80 x 36 mm. Equipment: 6/10/16 mm². Track Length: 84 mm
C M: Pce
14. ionised smoke detector installation: Device for use in a tertiary environment, ERP, etc. with networking on DAD cabinet. Ivory colored ABS terpolymer. High performance analysis room with photocell and light source. Power supply: DC 16-28 V. Consumption (under 24V) 130 uA in standby and 28mA in alarm. Dimensions: Ø 102 x 46 mm thickness
C M: Pce
15. Heat Detector Installation: visual light diffuser Diffuser to alert in case of fire alarm, the deaf and hard about the need to evacuate lieux.Conformes with NF EN, CE certified DPC and NF SSI . Fixing surface or flush mounted. IP 40 - IK 07
C M: Pce
16. Red manual release Installation: Complies with the NF EN, CE certified DPC and NF SSI. Triggered by pressure in the center of the membrane. Reset with special key provided with the product. Fixing surface or flush mounted. IP 40 - IK 07. Class II.
C M: Pce
17. Installation of fire alarm sound: Surface mounting. Red Flash. Sound: 90 dB at 2 m (Class B). IP42 - IK07. Product Standard: Complies with EN 54-3, NF S 32-001 and CE DPC and NF SSI.
C M: Pce
18. Installation of electric cables VOB 1.5 mm2 Rigid cable HO7 VU (solid round copper) PVC insulating sheath. Uses: residential premises of circuits led arises under or in wand. Wiring and wiring tables and equipment;
CM: At ml
19. Installation of electric cables VOB 2.5 mm2 Rigid cable HO7 VU (solid round copper) PVC insulating sheath. Uses: residential premises of circuits led arises under or in wand. Wiring and wiring tables and equipment; CM: At ml
20. Installation of telephone cables 0.6mm: PVC insulation. Assembly in pairs. Tape to maintain the assembled cable. Polyester coated aluminum screen. Nylon thread for tearing of the sheath. PVC jacket. Uses: private telephony systems installed outside buildings. Laying buried permitted. Current weak links of general applications requiring drivers assembled in pairs. Product Standard: Marking: according to standard NFC 93-529.
[Disclaimer: The below text is machine translated. For accurate information kindly refer the above text in original language.]
Documents
Similar Tenders
Burundi
151673904
16 Nov 2026
Refer Document
Procurement Documents for Burundi
Access a comprehensive library of standard procurement documents specific to Burundi. Here, you'll find all the essential forms, guidelines, and templates required for tender applications and submissions in Burundi
Want To Bid in This Tender?
Get Local Agent Support in Burundi and 60 More Countries.
View Tenders By
Sign in with Google