Procurement Summary
Country: Oman
Summary: Atomic Absorption Spectrometer, Oty: 1
Deadline: 27 Apr 2026
Posting Date: 06 Apr 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 139065435
Document Ref. No.: 1234/26/0042
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
ATOMIC ABSORPTION SPECTROMETER, Oty: 1 Category : Equipment Last Date Of Submission : 27/04/2026
SQU Product Code : EQUMEASPE0001 Description : ATOMIC ABSORPTION SPECTROMETER Quantity : 1 Remark : [EQUMEASPE0001] ATOMIC ABSORPTION SPECTROMETER-Combined Flame + Graphite Furnace Atomic Absorption Spectrophotometer. Wavelength Range 185nm-900nmMonochromatic Czerny-Turner ConfigurationSpectral Bandwidth 0.2, 0.3, 0.5, 0.8, 1.2 nm (automatic selection)Wavelength Reproducibility 0.005 nmFlame: (Cu 324) 0.017 mg/L 1 %Abs using a 10 cm burner head (air/acetylene)Graphite furnace: (Pb 283) 0.79 μg/L 1 %Abs (for 20 μL, peak area evaluation)Deuterium background correction by D2 hallow cathode lampBurner Heads Titanium AlloyNebulizer Inert Adjustable Nebulizer, Flow Rate from 2ml - 6ml/min. Pt/Ir capillaryfor high acid concentrationAtomization Chamber Corrosion-resistant materialPosition Adjustment Automatic Automatic Setting of Optimum Height for Flame Burner.Safety Functions Burner Identification, Flame Sensor, Gas leak Sensor, Low GasPressure Sensor, Drain Trap Sensor, Power Loss Protection, Circulation Water (graphite), Over Temperature Sensor (graphite)Air CompressorAcetylene gas regulatorAutosampler, Hydride unit Not requiredOrganic solvent ring (Acetate)Hollow Cathode lamps (HCL):Na, Ca, K, Fe, Zn, Pb - Transversely heated graphite furnace atomizer (THGA) by integrated autosampler operation- Temperature range from 0 °C to 3000 °C, programmable in intervals of 0.5 °C, heating rate up to 3000 °C/s, real-time temperature control by QPC sensor, self check system- SiOSens solid state detector, wide range, linear read out 0.1-100%, low noise CSA, 5 V- Scraper for flame mode, automatic cleaner of burner head for save nitrous oxide operation- Air purge kit Spectrometer Maximum protection against dust and vapor (Optional)- Segmented flow star SFS 6.0 Flame Switching valve technology for stable flame conditions, small sample volumes and reduced carry over (Optional)- Na 589.0 & K 766.5, can work emission without HCL- 5 years warranty on optical componentsThe quota...
Documents
Tender Notice