Procurement Summary
Country: Brazil
Summary: Acquisition of Electrical Materials for Control Panels, Circuit Breakers, Contact Blocks, Relays, Electrodes, Buttons, Rotary Switches and Signal Lights, According to Established Conditions, Quantities and Requirements...
Deadline: 11 May 2026
Posting Date: 27 Apr 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 140224645
Document Ref. No.: 93032/2026
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
Object: Electronic Auction - Acquisition of electrical materials for control panels, circuit breakers, contact blocks, relays, electrodes, buttons, rotary switches and signal lights, in accordance with the conditions, quantities and requirements established in the Notice and its Attachments. UASG code: 930098 Notice from: 04/27/2026 from 08:00 to 17:59 Proposal Delivery: from 04/27/2026 at 08:00 HIGH VOLTAGE CIRCUIT BREAKER, THREE-POLE TYPE, INDOOR USE, FIXED INSTALLATION, OPERATING VOLTAGE 690 V, NOMINAL CURRENT 5000 A, NOMINAL FREQUENCY 50/60 HZ, SUPPORTABLE VOLTAGE IMPULSE MANEUVER 12 KV, SYMMETRIC INTERRUPTION CAPACITY 100 KA, INTERRUPTION TIME 80MS, TECHNICAL STANDARDS EN/IEC 60947-1, EN/IEC 60947-24, THREE-POLE CONTROL, CURRENT NOMINAL SHORT CIRCUIT 220 KA 690 V, THERMOMAGNETIC OPERATION, FIXED MODEL Quantity: 53 HIGH VOLTAGE CIRCUIT BREAKER, TRIPLE TYPE, INDOOR USE, FIXED INSTALLATION, OPERATING VOLTAGE 690 V, NOMINAL CURRENT 5000 A, NOMINAL FREQUENCY 50/60 HZ, WITHSTANDABLE VOLTAGE IMPULSE SWITCH 12 KV, CAPACITY SYMMETRIC INTERRUPTION 100 KA, INTERRUPTION TIME 80MS, TECHNICAL STANDARDS EN/IEC 60947-1, EN/IEC 60947-24, TRIPOLAR CONTROL, NOMINAL SHORT CIRCUIT CURRENT 220 KA 690 V, THERMOMAGNETIC OPERATION, FIXED MODEL Quantity: 21 HIGH VOLTAGE CIRCUIT BREAKER, TYPE TRIPOLAR, INTERNAL USE, FIXED INSTALLATION, OPERATING VOLTAGE 690 V, NOMINAL CURRENT 5000 A, NOMINAL FREQUENCY 50/60 HZ, WITHSTANDABLE VOLTAGE IMPULSE MANEUVER 12 KV, SYMMETRIC INTERRUPTION CAPACITY 100 KA, INTERRUPTION TIME 80MS, STANDARDS TECHNIQUES EN/IEC 60947-1, EN/IEC 60947-24, TRIPOLAR CONTROL, NOMINAL SHORT CIRCUIT CURRENT 220 KA 690 V, THERMOMAGNETIC OPERATION, FIXED MODEL Quantity: 41 HIGH VOLTAGE CIRCUIT BREAKER, THREE-POLE TYPE, INDOOR USE, FIXED INSTALLATION, OPERATING VOLTAGE 690 V, NOMINAL CURRENT 5000 A, NOMINAL FREQUENCY 50/60 HZ, SUPPORTABLE VOLTAGE IMPULSE MANEUVER 12 KV, SYMMETRIC INTERRUPTION CAPACITY 100 KA, INTERRUPTION TIME 80MS, TECHNICAL STANDARDS EN/IEC 60947-1, EN/IEC...
Documents
Tender Notice