Procurement Summary
Country: USA
Summary: Wapa Replace Pcu at Vc
Deadline: 31 Mar 2026
Posting Date: 24 Mar 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 138335239
Document Ref. No.: 140P8226B0005
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
Sources Sought to REPLACE 17.5-TON PACKAGE COOLING UNIT (PCU) & APPURTENANCES AT THE VISITOR CENTER at WAR IN THE PACIFIC NATIONAL HISTORICAL PARK (WAPA) GUAMThis is a Sources Sought announcement to be used for preliminary market research purposes only. No bids are being requested or accepted from this announcement. THIS IS NOT A SOLICICTATION FOR BIDS AND NO CONTRACT SHALL BE AWARDED FROM THIS SYNOPSIS. The type of solicitation to issue will depend upon the responses to this synopsis. No reimbursement will be made by the Government for any costs associated with providing information in response to this synopsis of a follow up information. The purpose of this synopsis is to gain knowledge of interest, capabilities and qualifications of various members of 8(a), HUBZone, Service-Disabled Veteran-Owned Small business (SDVOSB), Women Owned Small Business (WOSB), Economically Disadvantaged Women Owned Small business (EDWOSB), and Indian Small Business Economic Enterprises (ISBEE) to compete and perform a Firm Fixed Price contract.The National Park Service, ConOps West, has a requirement to Replace 17.5 Ton Packaging Unit (PCU) and Appurtenances at the Visitor Center at War in the Pacific National historic Park (WAPA) Guam. Work will consist of the following:• Replace the existing PCU #3 and appurtenances on the roof of the T. Stell Newman Visitor Center at War in the Pacific National Historical Park• Remove and properly dispose of the existing PCU #3 and appurtenances• Power wash the existing concrete pad (8- wide x 11--4” long x 5.5” high) in preparation for the new PCU. Properly contain and dispose of debris and water from power washing• Install a new 17.5-Ton Carrier Model PCU meant for rooftop applications in inclement weather on the existing 8- x 11--4” concrete pad on the roof. The new PCU shall be 208V, 3-Phase, 60 HZ. The PCU must fit on the existing concrete pad, and the return / supply ducts must be positioned in the rear of the unit facing the wall.• The new P...
Notice ID: 140p8226b0005
Department/Ind. Agency: interior, department of the
Sub-tier: national park service
Office: pwr hono mabo(82000)
Product Service Code: z2aa - repair or alteration of office buildings
NAICS Code: 238220 - Plumbing, Heating, and Air-Conditioning Contractors
Inactive Dates: apr 30, 2026
Inactive Policy: manual
Documents
Tender Notice
Documents.zip