Procurement Summary
Country: USA
Summary: vpro max2 low temp sterilizers
Deadline: 10 Feb 2026
Posting Date: 31 Jan 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 134811133
Document Ref. No.: 36C25526Q0168
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
1. STATEMENT OF WORK
The contractor shall furnish all requisite services, labor, travel, transportation, materials, shipping,
parts, connections, and equipment for the provision and on-site installation of a minimum of three
vaporized hydrogen peroxide Low Temperature Sterilizers. These units are to be located at 4801
Linwood Blvd, Kansas City MO 64128. These low temperature sterilizers are essential for the Sterile
Processing Service (SPS) in reprocessing reusable medical devices (RMDs) employed in invasive
procedures. needed to support Sterile Processing Service (SPS) for reprocessing reuseable medical
devices (RMD) used in invasive procedures. Furthermore, these units are critical for supporting
medical procedures and surgeries and surgeries conducted within the Operating Room, as well as
in various ancillary clinics throughout the KCVA.
The contractor shall additionally furnish training to clinical personnel prior to the utilization of the
equipment. This training is to encompass all tours of duty for the sterile processing department and
necessitate annual retraining on all associated on all associated equipment. Moreover, the
contractor bears the responsibility for the removal and disposal of all debris and packaging
material resulting from the installation of the VPRO MaX2 Low Temp Sterilizers.
2. SPECIFICATIONS
• Three low temperature sterilizers shall have a minimum individual dimensions of Cabinet
(DD): 33 x 40-15/16 x 72” (838 x 1040 x 1829 mm) with Recessed/Cabinet (SD): 33 x
38-5/16 x 72” (838 x 973 x 1829 mm).
o Mounting single door, cabinet
o System installation requires no plumbing, ventilation or air
o supply - only a dedicated electrical connection is needed. A power cord is supplied
for this connection
o The facility space in which the vehicle can occupy is approx. 35- x 110-.
• Vaporized hydrogen peroxide sterilization processes are particularly suited for sterilizing
heat...
Notice ID: 36c25526q0168
Department/Ind. Agency: veterans affairs, department of
Sub-tier: veterans affairs, department of
Office: 255-network contract office 15 (36c255)
Product Service Code: 6515 - medical and surgical instruments, equipment, and supplies
NAICS Code: 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing
Inactive Dates: feb 25, 2026
Inactive Policy: 15 days after date offers due