Procurement Summary
Country: USA
Summary: Volcano Intrasight Philips
Deadline: 12 Dec 2025
Other Information
Notice Type: Tender
TOT Ref.No.: 131768109
Document Ref. No.: 36C25726Q0160
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
Page 7 of 7
Page 1 of
This market research notice is being conducted by Network Contracting Office (NCO) 17- VA Central Texas (VACTHCS) facilities.
The AVAMC (Amarillo VA Medical Center) requires a brand name or equal Philips Intrasight Mobile 5/Volcano. The Philips Volcano will attach to the GE Mac-Lab system in the CathLab which is currently being built. This piece will allow the Physician to be able to see the amount of blockage there is at any point in the artery. This will enable AVAMC to do interventional heart studies for the local Veterans, so they don t need to travel to another facility to get this care.
1. SERVICES:
This will include all pieces of the system needed to perform a Cardiac Catheterization, Stent Placement, Calculation of Blockage and other Interventional Studies. All installations shall follow the guidelines of The Joint Commission, NFPA, CDRH, VAMC. All work will Take place during normal business hours of 8-5, unless prior arrangements have been agreed upon. There will be no work conducted on any Government Holiday or after hours unless there is mutual Agreement between the COR and the installation team of Philips. All work must be Turn-key from the vendor.
Salient Characteristics:
Combined modalities on a single platform to provide a comprehensive view of the targeted vessel, these include:
Intravascular Ultrasound (IVUS) which provides detailed images of the vessel s interior to assess size, lesions, or plaques.
Instantaneous Wave Free Ratio (iFR) and Fractional Flow Reserve (FFR) which measure blood flow and pressure within vessels to evaluate significance of a blockage.
Angiography co-registration which integrates iFR and IVUS data with an angiogram, allowing the physician to map real-time pressure profiles and vessel measurements directly onto the x-ray image.
Integration with GE and/or Philips therapy systems to reduce data entry errors
9.7 diagonal monitor
1 CPU processor with 2/3 GHz
DICO...
Notice ID: 36c25726q0160
Department/Ind. Agency: veterans affairs, department of
Sub-tier: veterans affairs, department of
Office: 257-network contract office 17 (36c257)
Product Service Code: 6640 - laboratory equipment and supplies
NAICS Code: 339113 - Surgical Appliance and Supplies Manufacturing
Inactive Dates: jan 01, 2026
Inactive Policy: manual
Documents
Tender Notice