HOMELAND SECURITY, DEPARTMENT OF has floated a tender for Uscgc Maria Bray Grey Water Tank Open and Inspect. The project location is USA and the tender is closing on 07 May 2024. The tender notice number is 70Z08524P0004504, while the TOT Ref Number is 100414193. Bidders can have further information about the Tender and can request the complete Tender document by Registering on the site.

Expired Tender

Procurement Summary

Country : USA

Summary : Uscgc Maria Bray Grey Water Tank Open and Inspect

Deadline : 07 May 2024

Other Information

Notice Type : Tender

TOT Ref.No.: 100414193

Document Ref. No. : 70Z08524P0004504

Competition : ICB

Financier : Self Financed

Purchaser Ownership : Public

Tender Value : Refer Document

Purchaser's Detail

Purchaser : HOMELAND SECURITY, DEPARTMENT OF
Contracting Office Address : ALAMEDA, CA 94501
Primary Point of Contact : KYLER FISK
KYLER.C.FISK@USCG.MIL
Phone Number 9492881271

Secondary Point of Contact : BRENDEN COX
BRENDEN.S.COX@USCG.MIL
Phone Number 12068315347
USA
Email :kyler.c.fisk@uscg.mil

Tender Details

Description

USCGC MARIA BRAY (WLM-175) DOCKSIDE AVAILABILITY FY2024 122 (Rev-0) 59320_ESD_0323_FLT WORK ITEM 26: Grey Water Piping, Clean and Flush 1. SCOPE 1.1 Intent. This work item describes the requirements for the Contractor to clean the grey water piping system. 1.2 Government-furnished property. None. 2. REFERENCES COAST GUARD DRAWINGS Coast Guard Drawing 175 WLM 593-001, Rev G, Sewage and Waste Water System Diagram COAST GUARD PUBLICATIONS Surface Forces Logistics Center Standard Specification 0000 (SFLC Std Spec 0000), 2022, General Requirements OTHER REFERENCES 3. REQUIREMENTS 3.1 General. 3.1.1 CIR. None. 3.1.2 Tech Rep. Not applicable. 3.1.3 Protective measures. The Contractor must furnish and install all protective measures in accordance with SFLC Std Spec 0000, paragraph 3.3.3 (Vessel component, space, and equipment protection). USCGC MARIA BRAY (WLM-175) DOCKSIDE AVAILABILITY FY2024 123 (Rev-0) 3.1.4 Interferences. The Contractor must handle all interferences in accordance with SFLC Std Spec 0000, (Interferences). Known interferences include, but are not limited to the following: Grey water pumps 3.2 Contamination prevention. The Contractor must take all precautions to prevent contamination of personnel and spaces in accordance with all applicable Federal, state, and local regulations. 3.3 Personnel qualification. The Contractor must ensure that personnel accomplishing this work are qualified and experienced in operating the pressurized water system and handling the chemicals. For each operator/cleaning technician, submit documentation of applicable experience and training obtained within the last twelve months along with the Cleaning Plan (see paragraph 3.5.6.2). NOTE Coast Guard personnel will operate all shipboard machinery and equipment. 3.4 Operational test, initial. Prior to commencement of work, the Contractor must witness Coast Guard personnel perform an initial operational test of all items or shipboard devices to be disturbed, used, repa...
Active Contract Opportunity Notice ID 70Z08524P0004504 Related Notice Department/Ind. Agency HOMELAND SECURITY, DEPARTMENT OF Sub-tier US COAST GUARD Office SFLC PROCUREMENT BRANCH 2(00085)
General Information
Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
All Dates/Times are: (UTC-07:00) PACIFIC STANDARD TIME, LOS ANGELES, USA
Original Published Date: Apr 23, 2024 10:54 am PDT
Original Date Offers Due: May 07, 2024 08:00 am PDT
Inactive Policy: 15 days after date offers due
Original Inactive Date: May 22, 2024
Initiative: None

Classification
Original Set Aside:
Product Service Code: J020 - MAINT/REPAIR/REBUILD OF EQUIPMENT- SHIP AND MARINE EQUIPMENT
NAICS Code: 336611 - Ship Building and Repairing

Place of Performance: Atlantic Beach, FL 32233 USA

Documents

 Tender Notice