Procurement Summary
Country: USA
Summary: Ultrasound
Deadline: 21 Jul 2026
Posting Date: 08 Jul 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 144714687
Document Ref. No.: 36C25226Q0521_2
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_detailsLogin to see details
Tender Details
ELLEX ABSOLU S ULTRASOUND CONSOLE WITH A-STD PROBE (P/N PCBX0037S1S) QTY:1
ELLEX BIOMETRY A-SCAN PROBE FOR ABSOLU Ground plate w/o filter QTY:2
ELLEX 15 MHz B PROBE FOR ABSOLU/ABSOLU S QTY:2
50 MHz LINEAR HIGH-RESOLUTION PROBE FOR ABSOLU/ABSOLU S SYSTEMS ONLY QTY:1
STANDARDIZED A PROBE (PROBE ONLY) FOR ABSOLU S MODULES ONLY QTY:5
ELLEX BOX OF CLEARSCANS QTY:1
ELLEX DICOM SOFTWARE FOR ABSOLU ULTRASOUND QTY:1
ELLEX WIRELESS 9 FUNCTION FOOTSWITCH FOR ABSOLU/ABSOLU S QTY:1
ELLEX ULTRASOUND CART FOR ABSOLU & COMPACT TOUCH 2 QTY:1
ELLEX ULTRASOUND CLINICAL APPLICATIONS TRAINING QTY:1
Salient Characteristics Brand Name or Equal:
A-scan Biometry: to verify measurements of the length of the eye (axial length)
-Immersion A-scan
-Direct contact A-scan
-QTY Two (2) Biometry A-scan transducers
-Auto Axial length average and standard deviation calculations
-IOL Formulas
-Lens Database
-measurement tools
B-scan
15 MHz B-scan probe
-Qty Two (2) Biometry B-scan transducers
UBM
-QTY One (1) UBM Transducer
-QTY Ten (10) single-use sterile UBM-probe cover devices
-QTY Six (6) 8-MHz A-scan diagnostic transducers
allows for: diagnosis of tumor lesions, diagnosis of retinal vitreous membrane detachment and diagnosis of Graves disease
-probe positioning feedback/visualization
-Static and dynamic image capture and storage
-Image Annotation
-pachymetry probe self-check/auto calibration
-DICOM networking, compatibility to send to Ziess Forum
-Footswitch
-height-adjustable cart with keyboard tray
-1-day on-site Clinical Applications training to identify sight threatening retinal lesions, such as ocular tumors measurements critical in determining what power lens implant to place in the eye after cataract surgery
-Sulcus-to-Sulcus measurements
-corneal thickness measurements
-IOP correction formulas
VA Networked Medical Device risk assessment doc...
Notice ID: 36c25226q0521_2
Department/Ind. Agency: veterans affairs, department of
Original Set Aside: service-disabled veteran-owned small business (sdvosb) set-aside (far 19.14)
Sub-tier: veterans affairs, department of
Office: 252-network contract office 12 (36c252)
Product Service Code: 6515 - medical and surgical instruments, equipment, and supplies
NAICS Code: 334510 - Electromedical and Electrotherapeutic Apparatus Manufacturing
Inactive Dates: aug 05, 2026
Inactive Policy: 15 days after date offers due
Documents
Tender Notice