Procurement Summary
Country: Poland
Summary: "Thermomodernization of Public Buildings in the Heat Pipes Commune"
Deadline: 03 Apr 2026
Posting Date: 20 Mar 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 138162464
Document Ref. No.: 2026/BZP 00162975/01
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
CPV Classification
45000000 - Construction work
45111100 - Demolition work
45421000 - Joinery work
45421100 - Installation of doors and windows and related components
45262100 - Scaffolding work
45321000 - Thermal insulation work
45410000 - Plastering work
45400000 - Building completion work
45261210 - Roof-covering work
45111220 - Scrub-removal work
90511000 - Refuse collection services
45331000 - Heating, ventilation and air-conditioning installation work
45330000 - Plumbing and sanitary works
45332200 - Water plumbing work
45310000 - Electrical installation work
45111200 - Site preparation and clearance work
45233200 - Various surface works
45233260 - Pedestrian ways construction work
45331100 - Central-heating installation work
42511000 - Heat-exchange units and machinery for liquefying air or other gases
45331110 - Boiler installation work
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_detailsLogin to see details
Tender Details
The building of the village community center in Wilamowice is located at 35 Wilamowice, on plot no. 34, commune. Ciewody, Lower Silesia Voivodeship. The facility is an independent, detached building. The scope of planned works includes: - Insulation of external walls with EPS polystyrene with a thickness of 15 cm and a thermal conductivity coefficient of 0.032 [W/m*K] along with the application of a thin-layer silicone plaster. - Insulation of window and door frames with EPS polystyrene, 3 cm thick and a thermal conductivity coefficient of 0.031 including the implementation of a thin-layer silicone plaster. - Insulation of flat roofs with full layers of polystyrene, 22 cm thick, with a heat conduction coefficient of 0.035 [W/m*K], with one-sided laminated roofing felt, together with a covering made of two-layer roofing felt. thermoweldable - Replacement of external door joinery, - Replacement of external window joinery, - Installation of air conditioners, - Replacement of electric heaters, - Installation of a photovoltaic installation. As part of the accompanying works: - Reconstruction and execution of the missing one concrete band made of concrete cubes. - Replacement of existing sheet metal flashings, - Replacement of external window sills and...
Documents
Tender Notice