1 UNIT - THERMOCOUPLE THERMOMETER, TRACEABLE TO NIST
For use with any Type-K probe/flip stand for bench-top use
Thermometer Features:
Temperature Range: -328 to 24980F (-200 to 1370oC)
Resolution: 0.10F/oC between -199 to 13690F (-128 to 742oC) outside range resolution 10F/0C
Accuracy: +1 from -58 to 13640F (-50 to 740oC), otherwise +2o
Minimum/maximum memory/alarm
Timer Features:
1 channel
Timing capacity: 23hours, 59 minutes to 1 minute
Accuracy: +0.01%
Additional Accessory:
Type-K Beaded probe - 3 pcs
- Triple purpose probe with waterproof cable
- Use with all Type-K thermometers
- Diameter is 0.06 -inch, PTFE cable length is 4 feet, weight: 1/2 ounces
Budget Allocated: P50, 000.00
1 UNIT - TOPLOADING BALANCE, 6200g maximum capacity
Technical Specifications:
Readability: 0.1g
Adjustment range w/ ext.: weights 2000-6200g
Repeatability (sd): 0.1g
Linearity: 0.2g
Stabilization time: 1s
IP Protection: IP54 in use
Minimum Weight (acc. To USP): 300g
Minimum Weight (acc. To 1%, k=2): 20g
Power Requirement: 12V/0.84A
Connectivity: Rs232 interface/USB
Special Features:
Metal Housing. High-grade chemical resistant die-cast aluminum housing
Monobloc Weighing Technology: Proven weighing technology for fast and accurate results,
Monobloc weighing cell guarantees long service life and extreme ruggedness.
Overload Protection. Protects the weighing cell against excess weight overload
FACT. Fully automatic time- and temperature-controlled internal adjustment.
Protection. Of main balance configuration against manipulation, Password lock.
Application. Piece counting, percent weighing, check weighing, dynamic weighing, statistics.
Includes:
1. Installation, Commissioning and initial operation of the instrument.
2. Local training on site
3. One (1) year warranty
4. Protective cover and two (2) pcs. Balance brush
Budget Allocated: P80, 000.00
1 SET - THERMOCOUPLE SET, RESISTANCE TEMPERATURE DETECTOR (RTD)
WITH TWO (2) ADDITIONAL RTD PROBES THAT HAVE A RANGE OF -40 TO 200 DEGREES CELSIUS
SPECIFICATIONS:
GENERAL SPECIFICAITONS
Display: Backlit LCD; LCD size: 2 x 1.5-A