ZALA COUNTY ST. RAPHAEL'S HOSPITAL has floated a tender for T.Catheter Heart Valve. Implantation with a Heart Valve. The project location is Hungary and the tender is closing on 04 Apr 2024. The tender notice number is 164243-2024, while the TOT Ref Number is 99026352. Bidders can have further information about the Tender and can request the complete Tender document by Registering on the site.

Expired Tender

Procurement Summary

Country : Hungary

Summary : T.Catheter Heart Valve. Implantation with a Heart Valve

Deadline : 04 Apr 2024

Other Information

Notice Type : Tender

TOT Ref.No.: 99026352

Document Ref. No. : 164243-2024

Competition : ICB

Financier : Self Financed

Purchaser Ownership : Public

Tender Value : Refer Document

Purchaser's Detail

Purchaser : ZALA COUNTY ST. RAPHAEL'S HOSPITAL
Address: Zrinyi Utca 1.
Town: Zalaegerszeg
NUTS-Code: HU223
Postal Code: 8900
Attn: Gasztonyi Beata
Phone: 36 92311420
Hungary
Email :zmkorhaz@zmkorhaz.hu
URL :https://www.zmkorhaz.hu

Tender Details

Part number Part name Basic quantity pcs/24 months

1 Transcatheter implantable self-expanding aortic biological artificial valve 30 pcs

2 Valve expansion balloons used in aortic valve stenosis, for TAVI pre- and post-dilation 30 pcs

3 Dedicated TAVI guide wire 30 pcs

4 TAVI entry gate to prevent complicationsserving covered stents 8 pcs

5 Vascular closure device suitable for blocking femoral artery puncture 32 pcs

6 Introducer sheet (introductory sheath) 30 pcs

7 Guide wire 260 cm, 0.035" extra stiff 60 pcs

8 Angiodyn guide wire 180 -220 cm, 0.035" straight 60 pieces

The contract is of a framework nature.

1. Transaction.implantable self-expanding aorta b. artificial valve

part 1: Transcatheterally implantable self-expanding aortic biological artificial valve

Minimum requirement

self-expanding, laser-cut nitinol frame, porcine pericardium with sails.

supraannular-valve function.

fully resealable system, even after 80% opening, morecan be easily repositioned and reinstalled.

the valve can be opened with continuous dosing.

minimum vessel diameter in the case of femoral penetration: 5.5 mm.

14 and 16 F equivalent

minimum skirt length of 13 mm- greater tolerance range.

a Hungarian speaker for the delivery at a pre-arranged time for the implantsmust provide a cardiologist specialist proctor

who will assist the surgeon in the intervention

the supplier must provide trained personnel for the implantations at a pre-arranged time for loading the artificial valve into the catheter

the supplier must ensure that the trained and...
Document Type: Contract Notice
Reference Number: EKR002011602023
Contract Type: supplies
Authority Type: body-pl
Doc Title: T.kateteres szivbill. beueltetes szivbillentyűvel
Dispatch Date: 2024-03-18
Publish Date: 2024-03-19
Submission Date: 2024-04-04

Documents

 Tender Notice