Procurement Summary
Country : Ireland
Summary : Supply of New Air Compressors and New Blowers for Wwtp at Medite Europe Dac '25
Deadline : 03 Jun 2025
Other Information
Notice Type : Tender
TOT Ref.No.: 119086300
Document Ref. No. : 5666547
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
MEDITE Europe DAC requires the supply and equipment commissioning of New Air-Cooled Compressors (2 no.) and New Blowers in WWTP (2 no.). Please note NO installation will be required and the decommissioning and the removal of the existing compressors and blowers will be undertaken by Medite Europe DAC. Background The plant is in operation for 24 hours per day, 7 days per week and 50 weeks per year. A reliable supply of compressed air is absolutely essential to our processes. Also, a reliable supply of air via blowers is absolutely essential to the biological life in WWTP plant. A recent evaluation by our Energy Partner EM3 of our existing compressors and blowers in WWTP - has highlighted based on high run hours greater than 100, 000 hours that four key assets are now recommended for replacement at Medite. There are four compressors in main compressor room, Kaeser 1 VSD, Kaeser 2 FS, Kaeser 3 FS, Kaeser 4 FS in existing compressor room. Desired usage for four air cooled compressors is three in service (two fixed and variable speed controlling)/one fixed speed left off in standby mode. There are two existing blowers (of two no.) in WWTP also require to be replaced. Therefore, the following tender requirements to market in parallel is required as one overall supply package: 1) Supply of two new fixed speed air-cooled compressors (to replace two fixed speed air-cooled compressors no. 2 + no. 3 of the four no. existing Kaeser compressors). 2) Supply of two new screw blowers in WWTP area of plant to replace two existing blowers. The air demand (of the main system) at present has been measured as maximum capacity of 6, 120 m3/hour of compressed air via three (fourth back-up) Kaeser screw compressors (Three duty/One Standby is desired working arrangement). Hence, two new fixed speed compressors must deliver at minimum 4, 080 m3/hour to peak at 4, 500 m3/hour at supply pressure of 7.4 bar(g) with a mean demand of 4, 100 m3/hour as shown below in recent compressed air mapping study...
Procedure : Open
Publication Date : 03/06/2025
Deadline : 03/06/2025 15:00:00
Documents
Tender Notice