Procurement Summary
Country: USA
Summary: Sunset Nature Lodge Hvac Replacement
Deadline: 16 Jul 2026
Posting Date: 19 Jun 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 143612227
Document Ref. No.: 25-0260-PR
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
General work description: The City of Florissant is soliciting sealed bids from qualified HVAC contractors to furnish all labor, materials, equipment, permits, supervision, and incidentals necessary to remove and replace three (3) existing HVAC split systems at Sunset Nature Lodge.The replacement units shall be Sure Comfort Vantix™ Line Side-Discharge Universal Heat Pumps, Model RD18AY Series, matched with compatible inverter-driven air handling equipment and electric backup heat as specified herein.See Exhibit A in attachments for detailed specs. No substitutions, alternates, equals, or approved equivalents will be accepted.Project Location: Sunset Nature Lodge2300 Sunset Park DriveFlorissant, Missouri 63031Scope of WorkThe successful contractor shall provide all labor, materials, equipment, tools, transportation, and supervision necessary to complete the following:Demolition and RemovalDisconnect and remove three (3) existing HVAC split systems currently serving Sunset Nature Lodge.Recover refrigerant in accordance with EPA regulations.Remove and legally dispose of all existing condensers, air handlers, refrigerant piping, controls, and related components designated for replacement.Protect existing building finishes and adjacent facilities during removal operations.New Equipment InstallationProvide and install:Three (3) Sure Comfort Vantix™ Line Side-Discharge Universal Heat PumpsModel Series: RD18AYCapacity: 5 Ton (or size matching existing load requirements)Efficiency:Cooling Efficiencies up to 19 SEER2/13 EER2Heating Efficiencies up to 10 HSPF2Refrigerant: R-454BInverter-driven variable speed compressor technologyThree (3) matching compatible inverter air handlers with:Variable-speed blower motorsElectric backup heat packagesFactory-approved communicating controlsRefrigerant PipingInspect existing refrigerant line sets.Flush and clean reusable line sets using approved refrigerant line flushing procedures.Replace any damaged or unsuitable piping as required.Pres...
Documents
Tender Notice