Procurement Summary
Country : USA
Summary : Sources Sought for Laser-induced Breakdown Spectroscopy
Deadline : 06 Jun 2025
Other Information
Notice Type : Tender
TOT Ref.No.: 120262159
Document Ref. No. : DOIGFBO250044
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Description
SOURCES SOUGHT: This is a SOURCES SOUGHT NOTICE. The U.S. Geological Survey is conducting a MARKET SURVEY to determine the interest and capability of any firm eligible to compete under NAICS Code: 334516 - Analytical Laboratory Instrument Manufacturing with a Small Business Size Standard 1, 000 employees for an upcoming requirement for a Laser-induced breakdown spectroscopy (LIBS). THIS IS NOT A SOLICITATION. ALL COST ASSOCIATED WITH PROVIDING INFORMATION AS REQUESTED BY THIS SOURCES SOUGHT NOTICE SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. Submission is voluntary. Requirements include but not limited to: 1. LIBS must include Nd:YAG laser operating at the 4th harmonic of 266 nm with 12 mJ operating power at this wavelength and be capable of firing up to 20 Hz and come with safety interlocks. Laser spot size down to a minimum of 20 micron resolution. 2. The spectrometer¿s spectral range must cover at least 190 ¿ 1000 nm with a spectral resolution better than or equal to 0.1 nm. A calibration lamp to confirm wavelength must be included.3. Microscope must allow for simultaneous sample viewing and laser focusing, include a polarizing filter, motorized objective turret with 3 positions.4. A gas purge and extraction system must be present to allow for removing of generated dust to keep a clean sample surface at the analysis location. 5. Stage must travel at least 100 mm x 100 mm in the x-y plane with at least 50 mm of travel in the z direction. The stage step must be able to move in 1 micrometer steps.6. A variety of sample holders to accommodate irregular shapes and geologic thin sections that allow for transmitted light must be included. An airtight ablation cell must also be included for coupling to an inductively coupled-plasma mass spectrometer. 7. Software must fully control all aspects of the unit. It must be able to collect a spectrum from spot, line, grid of points, and depth profiling. A map must consist of a hyperspectral data set (full spectr...
Active Contract Opportunity
Notice ID : DOIGFBO250044
Related Notice
Department/Ind. Agency : INTERIOR, DEPARTMENT OF THE
Sub-tier : US GEOLOGICAL SURVEY
Office: OFC OF ACQUISITION GRANTS-DENVER
General Information
Contract Opportunity Type: Sources Sought (Original)
Original Published Date: Jun 03, 2025 07:55 am EDT
Original Response Date: Jun 06, 2025 01:00 pm EDT
Inactive Policy: 15 days after response date
Original Inactive Date: Jun 21, 2025
Initiative: None
Classification
Original Set Aside:
Product Service Code: 6640 - LABORATORY EQUIPMENT AND SUPPLIES
NAICS Code: 334516 - Analytical Laboratory Instrument Manufacturing
Place of Performance:
Documents
Tender Notice