Procurement Summary
Country: Ireland
Summary: Single Party Framework for the Provision of Of Legionella Control Services for Kerry County, Cork University Hospital, Cork County and University Hospital Kerry
Deadline: 25 Apr 2025
Posting Date: 20 Mar 2025
Other Information
Notice Type: Tender
TOT Ref.No.: 116471598
Document Ref. No.: 5319173
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
CPV Classification
90713100 - Consulting services for water-supply and waste-water other than for construction
90733000 - Services related to water pollution
90733600 - Transboundary water pollution management or control services
90733700 - Groundwater pollution monitoring or control services
90733100 - Surface water pollution monitoring or control services
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_detailsLogin to see details
Tender Details
Planned Maintenance and Inspection- All Locations • Monitoring of hot and cold water temperatures incl sentinel outlets • General Monitoring, including annual drain down on domestic hot water vessels/plate heat exchangers/Calorifiers for inspection, Chlorination and cleaning (base flush) • Performing Annual Disinfection and Cleaning of Cold Water Storage Tanks (inc Fortic type or close coupled tanks) and Associated Down Water Services • Measure and record Calorifier flow and return temperatures • Check and record operation of secondary pumps • Measure and record Water Heater Temperatures • Measure temperature of incoming main and storage tanks. • Inspect internal condition of water tanks • Measure temperature of representative selected outlets on a rotational basis. • Measure and record CWST consumption to ensure 24 hour turnover • Perform calibration on thermometers and probes. • De-scaling of Showerheads (inc hoses) and other outlets on a Quarterly basis • Performing Annual TMV Maintenance • Flush through and purge to drain -Expansion Vessels • Performing Bi -Annual Water Sampling and test For Legionella Pneumophilla, • Performing Annual Total Viable Counts ( TVC-s) /Escherichia Coli or Coliforms on CWST-s • Inspect Air Handling units cooling condensate drains Responsive- All Locations • Emergency disinfection of systems when deemed necessary following sampling • Addressing localised water hygiene issues including Legionella • Repairs to water softeners • Microbiological Monitoring and Monitoring for legionella
Procedure : Open
Publication Date : 25/04/2025
Deadline : 25/04/2025 00:00:00
Documents
Tender Notice