Procurement Summary
Country: USA
Summary: Secondary Level Direct Current Comparator DC Resistance Ratio Bridge
Deadline: 31 Dec 2019
Posting Date: 20 Dec 2019
Other Information
Notice Type: Tender
TOT Ref.No.: 39101015
Document Ref. No.: PANRSA-20-P-0000-003951
Competition: ICB
Financier: Self Financed
Purchaser Ownership: -
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
Secondary Level Direct Current Comparator DC Resistance Ratio Bridge
Active Contract Opportunity
Notice ID : PANRSA-20-P-0000-003951
Related Notice
Department/Ind. Agency : DEPARTMENT OF DEFENSE
Sub-tier : DEPT OF THE ARMY
Major Command : AMC
Sub Command : ACC
Office : ACC-CTRS
General Information
Contract Opportunity Type: Sources Sought (Original)
All Dates/Times are: (UTC-06:00) CENTRAL STANDARD TIME, CHICAGO, USA
Original Published Date: Dec 17, 2019 08:13 am CST
Original Response Date: Dec 31, 2019 02:00 pm CST
Inactive Policy: 15 days after response date
Original Inactive Date: Jan 15, 2020
Initiative: None
Classification
Original Set Aside:
Product Service Code:
NAICS Code: 334515 - Instrument Manufacturing for Measuring and Testing Electricity and Electrical Signals
Place of Performance: Redstone Arsenal, AL 35898 USA
Description
The Army Contracting Command - Redstone, Redstone Arsenal, Alabama 35898 on behalf of the U.S. Army Test, Measurement, and Diagnostic Equipment Activity (USATA) hereby issues the following Sources Sought/Request for Information (RFI) to ascertain the level of interest of potential vendors desiring to contract for commercial services based on commercial catalog industry pricing. USATA is looking for potential vendors that can provide the equipment described below:
• Equipment Needed: Secondary Level Direct Current Comparator DC Resistance Ratio Bridge(2 Qty)
Minimum Specifications For Resistance Ratio Bridge System:
2.0 Minimum Technical Specifications
2.1 Measuring Ranges
2.1.1 resistance range 100?? to 100M?
2.1.2 source current range 0.1 to 100 Amps
2.1.3 source voltage to 100 Volts for high resistance measurements
2.2 Accuracy
2.2.1 basic accuracy of 0.1??/?
2.2.2 meets basic accuracy at faster reversal rates of 4 8 seconds or less.
2.2.3 performs middle range measurements rapidly (results averaging 30 readings in 5 minutes or less).
2.2.4 manufacturer s accuracy claims verified by 3rd party testing.
2.2.5 delivered with certificate of calibration from ISO 17025 accredited laboratory.
2.3 Support
2.3.1 Must be supportable by with current APSL resistance laboratory standards to enable future periodic recalibrations.
2.3.2 Full performance test of ranges able to be performed by APSL in one day or less.
• Issue: USATA requires a higher accuracy and /or power buffering ability for measuring resistance.
THIS IS A REQUEST FOR INFORMATION (RFI) ONLY This RFI is released pursuant to FAR 15.201(e). It is issued solely for information and planning purposes only. It does not constitute a Request for Proposal (RFP) or a promise to issue an RFP in the future. This RFI does not commit the Government to contract for any supply or service whatsoever. ...