Procurement Summary
Country : USA
Summary : Safety Air Monitoring and Analytical Referee System (SAMARS) Gas Chromatograph (GC)
Deadline : 10 Mar 2025
Other Information
Notice Type : Tender
TOT Ref.No.: 115383121
Document Ref. No. : W911S6-24-Q-0034
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Description
***SUBJECT TO AVAILABILITY OF FUNDS***
Please provide a quote and indicate the maximum time frame for which this price will remain valid.
Procure two GC instruments with the following specifications:
Flame Photometric Detector (FPD); one instrument with phosphorous optical filter, one instrument with sulfur optical filter Chromatographic columns: one instrument DB-1701 phase and one instrument DB-210 phase column; Air sampling pre-concentrator trap capability with flow rate through the trap of at least 500 mL/min External mass flow controller, ability to capture the flow meter readings Oven programmable from ambient to 400℃ Cycle time from injection to injection of 15 minutes or less Visible and audible alarms for system faults and sample concentration detections Quick change trap assembly, flow rate of 500 mL/min with ability to change the preconcentrator tube in approximately 1 minute Onboard integration engine with graphical use interface. Ability to operate the instrument, calibrate, troubleshoot, analyze samples, etc. from the user interface. Visual readouts displayed of set points and measurements such as: sample flow, temperatures, pressures, concentrations, injection types, valve status, voltage, etc. Data logging. Ability to capture instrument set points and measured values such as: flow, temperatures, pressures, calibration, concentration, injection type - calibration, service, sample, etc. Data captured locally with the ability to retrieve and use for other reporting or calculating of sample data. Automatic calibration feature. Calibration of the instrument using an averaged single point or multi-point calibration curve. Capable of calibrating and obtaining sample concentrations using the onboard integration engine, and values displayed on the graphical user interface. Heated exhaust to prevent expulsion of water. Detector exhaust must expel water in gas/vapor form elimination water drip from the instrument detector. Sample by...
Active Contract Opportunity
Notice ID : W911S6-24-Q-0034
Related Notice
Department/Ind. Agency : DEPT OF DEFENSE
Sub-tier : DEPT OF THE ARMY
Major Command : AMC
Sub Command : ACC
Sub Command 2 : MISSION & INSTALLATION CONTRACTING COMMAND
Sub Command 3 : 418TH CSB
Office : W6QM MICC-DUGWAY PROV GRD
General Information
Contract Opportunity Type: Combined Synopsis/Solicitation (Original)
Original Published Date: Feb 25, 2025 09:15 pm MST
Original Date Offers Due: Mar 10, 2025 11:00 am MDT
Inactive Policy: 15 days after date offers due
Original Inactive Date: Mar 25, 2025
Initiative: None
Classification
Original Set Aside:
Product Service Code: 6630 - CHEMICAL ANALYSIS INSTRUMENTS
NAICS Code: 334516 - Analytical Laboratory Instrument Manufacturing
Place of Performance: Dugway, UT 84022 USA
Documents
Tender Notice
SAMARS-Combined-Synopsis-Solicitation-SoleSource.pdf
JA-SAMARS_Redacted.pdf