VETERANS AFFAIRS, DEPARTMENT OF has floated a tender for Room Pressure Monitors. The project location is USA and the tender is closing on 24 Apr 2024. The tender notice number is 36C24824Q0892, while the TOT Ref Number is 100176453. Bidders can have further information about the Tender and can request the complete Tender document by Registering on the site.

Expired Tender

Procurement Summary

Country : USA

Summary : Room Pressure Monitors

Deadline : 24 Apr 2024

Other Information

Notice Type : Tender

TOT Ref.No.: 100176453

Document Ref. No. : 36C24824Q0892

Competition : ICB

Financier : Self Financed

Purchaser Ownership : Public

Tender Value : Refer Document

Purchaser's Detail

Purchaser : VETERANS AFFAIRS, DEPARTMENT OF
Contracting Office Address : TAMPA, FL 33637
Primary Point of Contact : Janice Fornaro
janice.fornaro@va.gov
Phone Number 727-398-9335

USA
Email :janice.fornaro@va.gov

Tender Details

Description

THIS IS A SOURCES SOUGHT NOTICE ONLY. This is not a solicitation for bids, proposals, proposal abstracts, or quotations. The purpose of this Sources Sought Notice is to obtain information regarding the availability and capability of all qualified sources to perform a potential requirement. The responses received from interested contractors will assist the Government in determining the appropriate acquisition method. The Department of Veterans Affairs (VA), NCO 08- is conducting a market research survey to identify potential qualified sources capable of providing BRAND NAME ONLY for Setra Systems, Inc. s, Room Pressure Monitors to be delivered to 10, 000 Bay Pines Blvd, Bay Pines, Florida 33744, Warehouse Building 110. Responses are due by 1:00 p.m. Eastern Standard Time (EST) on Wednesday, April 24, 2024.Brand Name Description: Setra Systems, Inc. Room Pressure MonitorsDraft Salient Characteristics:Room Pressure Monitors (RPM)***Brand Name Only***Brand Name is Setra Systems, Inc.Supply seventeen (17) Room Pressure Monitors for Building #23, Research area. Room pressure monitors are used in critical spaces where contamination must be avoided. Critical spaces include hospital rooms, isolation rooms, operating rooms, cleanrooms, pharmaceutical manufacturing areas, vivarium s, and data centers.Manufacturer: Setra Systems, Inc.Manufacturers Part Number: AMP205-ENG-BACRequired Specification for Building 23 room pressure monitors (must match):LCD Readout displaySterile processingSterile storageUSP 800 complianceLaundryIsolation Rooms (AII)Protective Patient RoomsEndoscopyBronchoscopyCritical & Non-Critical ASHRAE-170 SpacesSole Source Justification:DEPARTMENT OF VETERANS AFFAIRSJustification for Single Source Awards IAW FAR 13.106-1ForOver Micro-Purchase Threshold but Not Exceeding the SAT ($250K)Acquisition Plan Action ID: _____ 36C248-24-AP-3335____Contracting Activity: Department of Veterans Affairs, VISN 08, Bay Pines VA Medical CenterTransaction: 516-24...
Active Contract Opportunity Notice ID 36C24824Q0892 Related Notice Department/Ind. Agency VETERANS AFFAIRS, DEPARTMENT OF Sub-tier VETERANS AFFAIRS, DEPARTMENT OF Office 248-NETWORK CONTRACT OFFICE 8 (36C248)
General Information
Contract Opportunity Type: Sources Sought (Original)
All Dates/Times are: (UTC-04:00) EASTERN STANDARD TIME, NEW YORK, USA
Original Published Date: Apr 17, 2024 12:17 pm EDT
Original Response Date: Apr 24, 2024 01:00 pm EDT
Inactive Policy: Manual
Original Inactive Date: Jun 23, 2024
Initiative: None

Classification
Original Set Aside:
Product Service Code: 4130 - REFRIGERATION AND AIR CONDITIONING COMPONENTS
NAICS Code: 334519 - Other Measuring and Controlling Device Manufacturing

Place of Performance: C.W. Bill Young VA Healthcare System Bay Pines, FL 33744 USA

Documents

 Tender Notice