Procurement Summary
Country: USA
Summary: Rfi Integration of Salient Medical Alarms into a Medicisolated Medevac Communications System
Deadline: 17 Apr 2026
Posting Date: 21 Mar 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 138209855
Document Ref. No.: HT9426-26-RFI-WS02
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_detailsLogin to see details
Tender Details
Request for Information Notice HT9426-26-RFI-WS02 for “Integration of Salient Medical Alarms into a Medic-Isolated Medevac Communications System”.
This is a REQUEST FOR INFORMATION (RFI) ANNOUNCEMENT ONLY. The Government does not intend to award a contract on the basis of the RFI or otherwise pay for the information requested and responses will be treated as information only and not as a proposal. Requests for a solicitation will not receive a response. Responses to this RFI must be in writing.
The purpose of this RFI announcement is to conduct market research to make appropriate acquisition decisions and to gain knowledge of potential qualified offerors interested and capable of providing the “Integration of Salient Medical Alarms into a Medic-Isolated Medevac Communications System” described below. Documentation of technical expertise must be presented in sufficient detail for the Government to determine that your company possesses the necessary functional area of expertise and experience to fulfill the requirement.
The Defense Health Agency Contracting Activity, 808 Schreider Street, Fort Detrick, MD 21702, is seeking potential qualified offerors to provide application and services for the following:
Sensor Data Processor
Acquires medical alarms from medical devices using USB/Ethernet ports (but does not modify the actual medical equipment).
Convert the medical alarms into verbal alarms.
Can prioritize alarms and alarm content.
Broadcast these alarms wirelessly to medic radio/communications components.
Can do this for up to three (3) patients.
Medic Radio Requirements
Plays voice alarms through the medic-s communication components that only can be heard by the medic (not the pilots).
Voice alerts should give patient identifier (Patient 1, 2, or 3) and what the alarm is for, example (Patient 1, Heart Rate High)
Medic can still communicate with pilots and rest of crew using the communications system.
The North Ameri...
Notice ID: ht9426-26-rfi-ws02
Department/Ind. Agency: dept of defense
Sub-tier: defense health agency (dha)
Office: defense health agency
NAICS Code: 334220 - Radio and Television Broadcasting and Wireless Communications Equipment Manufacturing
Inactive Dates: may 02, 2026
Inactive Policy: 15 days after response date
Documents