Procurement Summary
Country: USA
Summary: Rfi for Distillation Instrument
Deadline: 15 Jun 2026
Posting Date: 13 May 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 141159759
Document Ref. No.: 68HE0M26Q0011
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
RFI for Distillation InstrumentREQUEST FOR INFORMATIONPursuant to FAR 10.002(b)(2)(ii)Distillation Instrument for Distillation of Petroleum Products at Atmospheric Pressure Groups 1-4 for EPA NVFEL***MADE IN AMERICA***This is a request for information (RFI) only. The EPA makes no guarantee that a solicitation or award will result from this RFI. The purpose of this RFI is for market research purposes only. EPA is seeking to purchase one (1) Distillation Instrument capable of performing distillation in accordance with ASTM D86 Standard Test Method for Distillation of Petroleum Products at Atmospheric Pressure Groups 1 - 4.The EPA identified one product, OptiDist 2, which meets the EPA-s required sampling and measurement capabilities needs and below requirements/specifications. However, it is foreign made.The required specifications for the distillation instrument are as follows:The distillation instrument must meet the following specifications for each of the items (1 - 10) listed below. There will be no exception to these specifications.1. Interface with the PAC IRIS software2. Have a self-positioning heating system3. Have a distillation rate of 2-10 mL/min4. Shall have a condenser system with a programmable temperature range of 0-65 degrees Centigrade and automatic cooling liquid level detection5. Shall have a receiving chamber with a programmable temperature range of 0 - 40 degrees Centigrade, corrosion proof and compatible with 100 mL and 200 mL flasks6. Shall have automated heater plate detection7. Shall have barcoded distillation flasks and barcode reader for automatic detection of flask size, composition and serial number8. Shall have dual optimization by measurement of the fluid in the flask and vapor in the neck of the flask9. Shall have automatic fire detection compatible with carbon dioxide10. Shall not exceed the following dimensions o 16 inches wideo 23 inches deepo 29 inches highThis RFI is seeking an American-Made distillation instrument that meets or e...
Notice ID: 68he0m26q0011
Department/Ind. Agency: environmental protection agency
Sub-tier: environmental protection agency
Office: lab - ann arbor, mi - co office
Product Service Code: 6640 - laboratory equipment and supplies
NAICS Code: 334516 - Analytical Laboratory Instrument Manufacturing
Inactive Dates: aug 12, 2026
Inactive Policy: manual
Documents
Tender Notice