Procurement Summary
Country : USA
Summary : Replace Boiler #2 and Correct Deficiencies at Boiler Plant
Deadline : 29 Jan 2025
Other Information
Notice Type : Tender
TOT Ref.No.: 111586621
Document Ref. No. : 36C24825R0023
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Description
Presolicitation NoticePresolicitation NoticePage 3 of 3Presolicitation Notice*=Required FieldPresolicitation NoticePage 1 of 3Pre-Solicitation Notice Date: 12/09/2024, Subject: Replace Boiler #2 and Correct Deficiencies at Boiler Plant (Construction Services). Location: VA Caribbean Healthcare System (VACHS), San Juan, PR. Proposed Solicitation Number: 36C24825R0023. Closing Response Date: 01/29/2025 @ 3:30PM (AST PR Local Time). POC: Ana G. Alvarado, email: ana.alvarado@va.gov. This requirement is 100% set-aside for Small Businesses (SB). General Description: The Department of Veteran Affairs (VA), Veterans Integrated Service Network (VISN) 8, VA Caribbean Healthcare System (VACHS) has a requirement to replace the existing boiler #2 with a new 350 HP firetube boiler and shall correct several identified deficiencies at the Boiler Plant. This new boiler shall use fuel-oil #2 as its primary fuel. The project shall also provide a new fuel oil pump and distribution system, a new chemistry laboratory, new electrical panels, new economizers on all three boilers and metering systems for steam, condensate, feedwater, and make-up water among other boiler plant improvements. Piping Tie-Ins shall be performed during weekends to minimize impact on the hospital operations. Underground fuel-oil piping shall be Glass Fiber Reinforced Plastic (FRP) with secondary containment pipe as per specification 23 10 00 and drawing MS-101. Existing dike (old day tank) lead-based paint shall be properly removed and disposed following state and federal requirements. Utility shutdowns shall be strictly coordinated with the facility, 14 days in advance, to minimize impact to daily operations. Shutdowns shall be performed during nights and weekends. Contractor shall be responsible to obtain all state and federal permits required for construction and waste disposal. The contractor shall provide a temporary boiler for the duration of the project. Boiler capacity shall be 350 HP at a ...
Active Contract Opportunity
Notice ID : 36C24825R0023
Related Notice
Department/Ind. Agency : VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier : VETERANS AFFAIRS, DEPARTMENT OF
Office: 248-NETWORK CONTRACT OFFICE 8 (36C248)
General Information
Contract Opportunity Type: Presolicitation (Original)
Original Published Date: Dec 10, 2024 11:34 am AST
Original Response Date: Jan 29, 2025 03:30 pm AST
Inactive Policy: Manual
Original Inactive Date: Mar 30, 2025
Initiative: None
Classification
Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
Product Service Code: Z2DA - REPAIR OR ALTERATION OF HOSPITALS AND INFIRMARIES
NAICS Code: 236220 - Commercial and Institutional Building Construction
Place of Performance: VA Caribbean Healthcare System (VACHS) 10 Calle Casia San Juan, 00921-3201
Documents
Tender Notice
36C24825R0023-BB-672-20-602-Replace-Boiler-2.docx