Summary: Reagentrental for Two Fully Automated, Randomaccess Analyzers for 59Th Medical Wing, Lackland Air Force Base, Texas
Deadline: 29 May 2026
Posting Date: 16 May 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 141392429
Document Ref. No.: HT940826RFI0003
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_detailsLogin to see details
Tender Details
1. Introduction
This is a Request for Information (RFI)/Sources Sought Notice (SSN). The Defense Health Agency (DHA) is conducting market research to determine if qualified businesses exist that can provide Reagent/Rental for two fully automated, random-access analyzers for 59th Medical Wing, Lackland Air Force Base, TX. This publication seeks to learn more about potentially capable vendors. This is not a solicitation, nor is it a request for proposals. This notice is for informational and planning purposes only and does not constitute a commitment, implied or otherwise, that a solicitation will be issued. The Government is not obligated to award a contract as a result of this notice.
2. Program Details
The 59 MDW has a potential requirement for two analyzer systems meeting, or exceeding, the technical specifications below. The system must be designed for high-volume laboratories, capable of testing up to 25 different analytes from a single sample tube. Must have a test menu that includes over 50 assays for autoimmune, infectious disease, and specialty immunoassay testing. Must streamlines workflow with high throughput (up to 1, 200 results/hour), rapid time-to-first result (45 minutes), and broad assay capability in autoimmune and infectious diseases. The system must offer a significant reduction in labor costs and improved patient care through faster, more detailed diagnostic information.
Salient Characteristic of the Analyzer requirement:
Physical Dimensions (space is extremely limited)
Height: no larger than 4.4-
Width: no larger than 4-3”
Depth: no larger than 2-10”
Operational clearance approximately 3-
Minimal System Maintenance:
Less than 10 minutes per day
Automated weekly maintenance requires 30 minutes or less
Electronic tracking of required maintenance tasks
Ensures maintenance is completed when due
Minimal hands-on time and labor devoted to maintenance procedures
Test Specifications-MMRV
Assay Specificit...
Notice ID: ht940826rfi0003
Department/Ind. Agency: dept of defense
Sub-tier: defense health agency (dha)
Office: defense health agency
Product Service Code: 6630 - chemical analysis instruments
NAICS Code: 334516 - Analytical Laboratory Instrument Manufacturing
Inactive Dates: jun 13, 2026
Inactive Policy: 15 days after response date
Documents
Tender Notice
Documents.zip