Procurement Summary
Country : Azerbaijan
Summary : Purchasing Laboratoria Devices
Deadline : 09 Jul 2025
Other Information
Notice Type : Tender
TOT Ref.No.: 121365193
Document Ref. No. : 113601
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : AZN 43803.37
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Uv-Vis, 1. The device will be used in regular laboratory analysis. The device's optical system must have a double beam feature.
2. The light source of the device should be xenon lamp with a service life for at least 5 years.
3. The device xenon light source should be under 3 years warranty.
4. Single, 8 positions with the device The rotating sample capacity must be provided.
5. The spectral bandwidth of the device must be 2-5 nm.
6. The device's detector must have a dual silicone photodiod.
7. The device's wavelength range must be between 190-1100 Nm.
8. The accuracy of the device's wavelength must be +/- 0.5 Nm.
9. The recurrence of the instrument The ability to be +/- 0.2 nm.
10. The device scanning speed can be adjusted slow, medium and fast to 1600 nm / minute, and data intervals can be adjusted by 0.1, 0.2, 0.5, 1.0, 2.0, 5.0 nm.
11. The device's photometric range should be between-2A and + 3.5A.
12. Photometric description of the device -3a Must be between + 5a.
13. The photometric accuracy of the device should be +/- 0.002a in +/- 0.5a, +/- 0.004a in 1.0a, +/- 0.008.
14. The device's photometric repetition capability must be +/- 0.001A in 1A.
15. The device's photometric noise cost 260 and 500 Nm in 0a ≤0.00020a, 260 and 500 Nm in 1A in 1A, in 1A, 2A ≤0.00040A in 50.m.
16. The device must be sliding from the underground line 0.0005a / hour.
17. The empty light value on the device is in 198NM (KCI) 1.0% t, 220nm (nai) 0.05% t, 340nm must be 0.03% t.
18. The device screen is sensitive to a 7-inch color touch and mobile, 800-820 x 1280-1300 pixels high-solvent screen should be.
19. The device should be portable and weighs should not exceed 7.5 kg.
20. You should be able to take 8 samples at the same time to hold the unit and The movement of the tubject holder must be managed through the device's management keys. The bathtub should not be handed.
21. All of the device management...
Number of bidders required: 3
Opening date and time of envelopes: 09.07.2025 16:00
Date and time of recent submission of proposals: 2025-07-09
Documents
Tender Notice