Purchase of One (1) Unit Mammogram Machine Tender - 5222050

The BENGUET GENERAL HOSPITAL has issued a Tender notice for the procurement of a Purchase of One (1) Unit Mammogram Machine in the Philippines. This Tender notice was published on 08 Feb 2016 and is scheduled to close on 25 Feb 2016, with an estimated Tender value of Refer Document. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 5222050, while the tender notice number is 2016R-01-026 and Registering on the platform.

Expired Tender

Procurement Summary

Country: Philippines

Summary: Purchase of One (1) Unit Mammogram Machine

Deadline: 25 Feb 2016

Posting Date: 08 Feb 2016

Other Information

Notice Type: Tender

TOT Ref.No.: 5222050

Document Ref. No.: 2016R-01-026

Competition: ICB

Financier: Self Financed

Purchaser Ownership: -

Tender Value: Refer Document

CPV Classification

33111650 - Mammography devices

Purchaser's Detail

Name: Login to see tender_details

Address: Login to see tender_details

Email: Login to see tender_details

Login to see details

Tender Details

ITEM QTY UNIT ITEM DESCRIPTION ESTIMATED ESTIMATED
NO. OF ISSUE UNIT COST COST
1 1 unit Mammogram Machine 4, 500, 000.00
Analog Mammography System
"-c GENERATOR CONSOLE:
Input Power: 200VAC +/- 10%, 50/60 Hz Single Phase 3Kva
Type: High Frequency Inverter kV Range: 22 - 39 kVp
mAs Range: 1, 1.3, 1.6, 2, 2.5, 3.2, 4.5, 6.4, 8, 10, 12.5, 16, 20, 25, 32, 40, 50, 64, 80, 100, 125, 160, 200, 250, 320, 400, 500 (30 step)
Control: Keypad membrane with Touch Panel L.C.D Display
L.C.D Darkness: 9 step
Radiographic Mode: Manual, Semi Auto and Automatic
AEC Detector: Semiconductors Equipment, Active Sensing Range 1 x 1 cm "
-c X-RAY TUBE
Tube Voltage:
" Large Focus with Mo. Filter 22 - 35 kV
"
Large Focus with Aluminum Filter 36 - 39 kV
Small Focus with Molybdenum Filter 22 - 35 kV
Tube Current:
Large Focus 85 mA/100 mA maximum
" Small Focus 15 mA/18 mAmaximum
"
mAs:
" Large Focus 1 - 500 mAs
"
Small Focus 1 - 160 mAs
Anode Rotation Speed: 3, 000 rpm
Anode Quality: Molybdenum
X- ray Window: Beryllium, 0.5 mm thickness
Anode Heat Storage: 211 kJ (300kHU)
Housing Continual Heat Loss: 100W (135 HU/sec)
Housing Heat Storage Ability: 370 kJ (500HU)
"-c COLLIMATOR
"
Power for use: 3.6 DCV/5W
Filter Switching Method: Manual Switching
Molybdenum: 0.3 mm Molybdenum
Inherent Filtration:0.5 mm Aluminum
-c C-ARM STAND
Up Down Stroke 800 mm (750 mm)
Rotation: +180 degrees to -179 degrees
SID: 560mm
-c CONTROL OF COMPRESSION
Force: Manual: 25 kg to 29 kg. Automatic 20 kg
Movement up and Down: Foot Switch 2 Position
Automatic Compression Force Set By C- Arm OP Side ( maximum of 20 kg)
Compression is released by foot switch module (UP screen)
" BUCKY DEVICE:
"
Line and Ratio: 36L/cm, 4:1
Compression Paddles: 18 cm x 24 cm
Range of X-ray: 18cm x 24cm
Size: 18cm x 24cm
OTHER REQUIREMENTS:
Must provide cassette compatible with the hospital''s CR system
Two years warranty on parts and service
One year free maintenance, free spare parts and labor
Must provide training for the end users.
x
4, 500, 000.00
Pre-bid Conference
DateTimeVenue
11-Feb-20161:30 PMStaff Dining, Benguet General Hospital, Km. 5, La Trinidad, Benguet

Documents

 Tender Notice


Similar Tenders

Request Demo
GiZ Tenders India

Procurement Documents for Philippines

Access a comprehensive library of standard procurement documents specific to Philippines. Here, you'll find all the essential forms, guidelines, and templates required for tender applications and submissions in Philippines

Explore Procurement Documents for Philippines


Want To Bid in This Tender?

Get Local Agent Support in Philippines and 60 More Countries.

View All The Services


View Tenders By


Publish Tenders


Have Any Dispute With The Purchaser?