Procurement Summary
Country: Azerbaijan
Summary: Purchase of Medical Equipment
Deadline: 09 Jan 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 132533402
Document Ref. No.: 2025/AT/00756/V2
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: AZN 1706300.00
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
Angiography, General requirements: 1. The device must be factory-made, new and unused; 2. Monoplane system - providing imaging from only one side (in one plane). should be done; 3. The equipment must have a CE certificate. System composition and technical indicators: 1. X-ray generator: It should be a high-frequency generator, with a minimum power of 80 kW should be, kVp range should be 40-125 Kv, mA range should be 10 - 1250 mA, Automatic dose adjustment (AEC) should be, Pulsed and fluoroscopic modes should be, User-defined must have 10+ anatomical programs that can be programmed; 2. X-ray tube: It should have a rotating anode, heat resistance min 1 MHU must be, Focal points must be minimum 2 (0.6 mm and 1.0 mm ), Anode speed must be 10000 rpm or higher, Heat dissipation system (with oil-cooling or air circulation); 3. Digital detector (Flat Panel Detector): Digital flat panel (a-si or CMOS), diagonal size should be 15 inch or larger, Pixel size should be maximum 200 µm, Matrix min. 2000 x 2000 pixels, At least 2.5 lp/mm resolution and 30 fps real video stream; 4. C-arm and Mechanics: Must be C-arm with motorized control, C-arm movements horizontal movement ±20 cm vertical ±40 cm rotation angle should be ±135º Fully automated iso-centric should be rotatable, and should have the possibility of manual control in simple and urgent cases. Imaging and processing functions: 1. Must have DSA (Digital Subtraction Angiography); 2. There should be Road Map (road map mode); 3. Cine Loop (continuous playback of recorded video) should be; 4. Must have Substraction and Mask modes; 5. Digital measurement tools: distance, area, angle and flow rate; 6. There should be interactive window width and level adjustment; 7. Real-time image capture and processing should be possible. Operator console and Monitors: 1. There should be a main control panel with a touch screen; 2. There should be at least 2 medical-grade 21" - 24" monitors (resolution min. Full HD); 3. One of the monitors is on...
Number of bidders required: 3 Date and time of opening of envelopes: 09.01.2026 15:30 Last date and time for submission of proposals: 2026-01-09
Documents
Tender Notice