Procurement Summary
Country: USA
Summary: Project no 53925508 Correct Imaging Tower Deficiencies
Deadline: 15 May 2026
Posting Date: 02 May 2026
Other Information
Notice Type: Tender
TOT Ref.No.: 140552542
Document Ref. No.: 36C25026B0044
Competition: ICB
Financier: Self Financed
Purchaser Ownership: Public
Tender Value: Refer Document
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_detailsLogin to see details
Tender Details
Description of purpose work nature and volume:
The chosen contractor shall provide complete construction services including labor, materials, equipment, and supervision required to complete the Correct Imaging Tower Deficiencies project for the Cincinnati VAMC. This project requires a full roof replacement above A2013 & A2016, a lead-lined door replacement in A2016 (in favor of something like a traditional double-door where both sides open with operator) and improved cooling capacity within CT equipment room A2016A.
The [Correct Imaging Tower Deficiencies] project is intended to replace the full roof above A2013 & A2016, along with lead-lined door replacement in A2016 (in favor of something like a traditional double-door where both sides open with operator). Additionally, this project will add cooling capacity to CT control room A2016A through the placement of a dedicated ductless split system with capacity to cool at a rate of up to 30k BTU/HR. The installation of this should be all inclusive of all carpentry, power and plumbing work.
The above construction Statement Of Work (SOW) constitutes a basic outline of work and in no way outlines all of the details for the construction of this project. It is recommended that a detailed inspection of the premises, drawings and specification be initiated to determine the needs and conditions for the construction of this project.
Period of Performance:
All phases of work, including project closeout documentation, to be completed & provided within 180 calendar days after issuance of the Notice To Proceed (NTP).
The magnitude of construction project is estimated between $500, 000 and $1, 000, 000
Location of the work:
All work to be performed, according to the drawings and specifications at the:
Cincinnati VA Medical Center
3200 Vine Street
Cincinnati, Ohio 45220-2637
Tentative dates for issuing invitations, opening bids, and completing contract performance;
The Invitation for Bids (IFB) ...
Notice ID: 36c25026b0044
Department/Ind. Agency: veterans affairs, department of
Original Set Aside: service-disabled veteran-owned small business (sdvosb) set-aside (far 19.14)
Sub-tier: veterans affairs, department of
Office: 250-network contract office 10 (36c250)
Product Service Code: y1da - construction of hospitals and infirmaries
NAICS Code: 236220 - Commercial and Institutional Building Construction
Inactive Dates: aug 13, 2026
Inactive Policy: manual
Documents
Tender Notice
Documents.zip