Summary: Procurement of Various Medical/Hospital Equipment
Deadline: 03 Jun 2020
Posting Date: 13 May 2020
Other Information
Notice Type: Tender
TOT Ref.No.: 42811809
Document Ref. No.: 2020-devmh-055
Competition: ICB
Financier: Self Financed
Purchaser Ownership: -
Tender Value: Refer Document
CPV Classification
31000000 - Electrical machinery, apparatus, equipment and consumables; lighting
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
Procurement of Various Medical/Hospital Equipment
QUANTITY UNIT DESCRIPTION UNIT COST TOTAL
2 UNIT Mechanical Ventilator 3-in-1 1, 400, 000.00 2, 800, 000.00
Patient Circuit Type: Adult/ Pediatric/ Neonatal
Light weight and sleek; vent unit and trolley not more than 26 kls.
Turbine Driven with maximum flow generator noise at 43dB
Recalibrates and self check at every start
Magnetic Flow sensor unaffected by humidity and patient discharge
Display: Touch Screen
* at least 12" TFT display
Pneumatic Specification:
* Maximum limited pressure: at least 127.5 cmH2O (125 hPa)
* Maximum Working pressure: at least 100 cmH2O (98.1 hPa)
* Exhaled tidal Volume Range: at least 0 to 6, 000 Ml
* Exhaled tidal Volume Range: at least 0 to 6, 000 mL
Connectors:
* Inspiratory limb connector: ISO 22 mm conical male
* Expiratory limb connetor (on expiratory filter: ISO 22-mm conical male
* Air and oxygen inlets: DISS female, NIST, Air Liquid or SIS fitting (depending on country and configuration)
Back Up Power Source (Battery)
* Bak Up Battery time: 4-6 hours
Modes:
* Assist/ Control (A/c)
* Synchronous Intermittent Mandatory Ventilation (SIMV)
* Spontaneous
* Bi-Level
Auto weaning
Software Options:
* Neonatal mode with N-CPAP
* Leak Compensation
* Tube Compensation
* Dead Space Compensation
* Bi-Level
* Volume Ventilation Plus (Volume Control Plus Volume Support)
* Proportional Assist Ventilation Plus
* Respiratory Mechanics
* Trending
*With auto weaning
*Nebulizer: integrated, synchronized at inspiratory
*Electromagnetic flow sensor can detect from 0.1L/min Tidal volume for neonates, pedia, adults
Mandatory Breath Types:
* Volume Control (VC)
* Pressure Control (PC)
* Volume Plus with Volume Ventilation Plus Option
Spontaneous Breath Types:
* Pressure Support (PS)
* Volume Support (VS)
* Proportional Assist (PA)
* None
Vent Type:
* Invasive
* Non-Invasive
Trigger Type:
* Pressure Triggering
* Flow Triggering
* Volume Triggering
with USB, RS232 ports and ETCO2
Ventilator Settings:
* Ideal Body Weight (IBW): 7.7 to 330.7lb (3.5 to 149kg);
0.5kg to 149kg) with Neonatal Mode
* Tidal Volume: as low as 2ml/min. (as low as 300 grams body weight)
* Pressure Support: 0 to 70 cm H2O
* Rise Time %: 1% to 100%
* Expiratory Sensitivity: 1% to 80%; 1 L/ min to 10 L/min with
PAV + Tidal Volume: 25 to 2, 500ml, 5 to 315 ml with Neonatal Mode
* Peak Inspiratory Flow: 1.0 to 30L/min with Neonatal Patient Circuit
3.0 to 60L/min with Pediatric Patient Circuit and
3 to 150L/min with Adult Patient Circuit
* PEEP: 0 to 45cm H2O
* Flow Pattern: Square or Descending Ramp
* Inspiratory Time: 0.2 to 8.0s
* O2 %: 21 to 100%
* Plateau Time: 0.0 to 2.0s
*Inspiratory flow at least 10cmHw to 90cmHw
*ET CO2 ready
*With PSV - TV and APRV modes
Alarm Settings:
* Apnea Interval
* High Circuit Pressure Limit: 7 to 100cm H2O
* High exhaled minute volume: 0.1 to 99.9l or OFF
* High exhaled tidal volume: 50 to 3000ml or Off, 5 to 300ml or
OFF with Neonatal Mode option
* High respiratory rate: 10 to 110/min or OFF
* High inspired mandatory tidal volume
* Low exhaled mandatory tidal volume: 5 to 2500ml or OFF,
1 to 300ml or OFF for neonatal mode
* Low Circuit Pressure Alarm Limit
* O2 Sensor
Monitored (Patient) Data:
* Breath Type
* Delivered O2%
* End Expiratory Pressure
* End Inspiratory Pressure
* Exhaled Minute Volume
* Exhaled Tidal Volume
* I:E Ratio
* Intrinsic PEEP
* Mean Circuit Pressure
* Peak Circuit Pressure
* Plateau Pressure
* Rapid Shallow Index
* Spontaneous Inspiratory Time
* Spontaneous Minute Volume
* Spontaneous Percent Inspiratory Time
* Static Compliance
* Static Resistance
* Total PEEP
* Total Respiratory Rate
Integral Waveforms functons:
* Pressure-time curve
* Flow-time curve
* Volume-time curve
* Pressure-Volume Loop
* Flow-Volume Loop
* All waveforms can be frozen
* Ad...
Closing Date : 2020-06-03