Cross Icon
Cross Icon

Procurement of Various Medical/Hospital Equipment Tender - 42811809

The DON EMILIO DEL VALLE MEMORIAL HOSPITAL has issued a Tender notice for the procurement of a Procurement of Various Medical/Hospital Equipment in the Philippines. This Tender notice was published on 13 May 2020 and is scheduled to close on 03 Jun 2020, with an estimated Tender value of Refer Document. Interested bidders can access detailed Tender information, eligibility criteria, and complete bidding documents by referencing TOT Ref No. 42811809, while the tender notice number is 2020-devmh-055 and Registering on the platform.

Expired Tender

Procurement Summary

Country: Philippines

Summary: Procurement of Various Medical/Hospital Equipment

Deadline: 03 Jun 2020

Posting Date: 13 May 2020

Other Information

Notice Type: Tender

TOT Ref.No.: 42811809

Document Ref. No.: 2020-devmh-055

Competition: ICB

Financier: Self Financed

Purchaser Ownership: -

Tender Value: Refer Document

CPV Classification

31000000 - Electrical machinery, apparatus, equipment and consumables; lighting

Purchaser's Detail

Name: Login to see tender_details

Address: Login to see tender_details

Email: Login to see tender_details

Login to see details

Tender Details

Procurement of Various Medical/Hospital Equipment
QUANTITY UNIT DESCRIPTION UNIT COST TOTAL
2 UNIT Mechanical Ventilator 3-in-1 1, 400, 000.00 2, 800, 000.00
Patient Circuit Type: Adult/ Pediatric/ Neonatal
Light weight and sleek; vent unit and trolley not more than 26 kls.
Turbine Driven with maximum flow generator noise at 43dB
Recalibrates and self check at every start
Magnetic Flow sensor unaffected by humidity and patient discharge
Display: Touch Screen
* at least 12" TFT display
Pneumatic Specification:
* Maximum limited pressure: at least 127.5 cmH2O (125 hPa)
* Maximum Working pressure: at least 100 cmH2O (98.1 hPa)
* Exhaled tidal Volume Range: at least 0 to 6, 000 Ml
* Exhaled tidal Volume Range: at least 0 to 6, 000 mL
Connectors:
* Inspiratory limb connector: ISO 22 mm conical male
* Expiratory limb connetor (on expiratory filter: ISO 22-mm conical male
* Air and oxygen inlets: DISS female, NIST, Air Liquid or SIS fitting (depending on country and configuration)
Back Up Power Source (Battery)
* Bak Up Battery time: 4-6 hours
Modes:
* Assist/ Control (A/c)
* Synchronous Intermittent Mandatory Ventilation (SIMV)
* Spontaneous
* Bi-Level
Auto weaning
Software Options:
* Neonatal mode with N-CPAP
* Leak Compensation
* Tube Compensation
* Dead Space Compensation
* Bi-Level
* Volume Ventilation Plus (Volume Control Plus Volume Support)
* Proportional Assist Ventilation Plus
* Respiratory Mechanics
* Trending
*With auto weaning
*Nebulizer: integrated, synchronized at inspiratory
*Electromagnetic flow sensor can detect from 0.1L/min Tidal volume for neonates, pedia, adults
Mandatory Breath Types:
* Volume Control (VC)
* Pressure Control (PC)
* Volume Plus with Volume Ventilation Plus Option
Spontaneous Breath Types:
* Pressure Support (PS)
* Volume Support (VS)
* Proportional Assist (PA)
* None
Vent Type:
* Invasive
* Non-Invasive
Trigger Type:
* Pressure Triggering
* Flow Triggering
* Volume Triggering
with USB, RS232 ports and ETCO2
Ventilator Settings:
* Ideal Body Weight (IBW): 7.7 to 330.7lb (3.5 to 149kg);
0.5kg to 149kg) with Neonatal Mode
* Tidal Volume: as low as 2ml/min. (as low as 300 grams body weight)
* Pressure Support: 0 to 70 cm H2O
* Rise Time %: 1% to 100%
* Expiratory Sensitivity: 1% to 80%; 1 L/ min to 10 L/min with
PAV + Tidal Volume: 25 to 2, 500ml, 5 to 315 ml with Neonatal Mode
* Peak Inspiratory Flow: 1.0 to 30L/min with Neonatal Patient Circuit
3.0 to 60L/min with Pediatric Patient Circuit and
3 to 150L/min with Adult Patient Circuit
* PEEP: 0 to 45cm H2O
* Flow Pattern: Square or Descending Ramp
* Inspiratory Time: 0.2 to 8.0s
* O2 %: 21 to 100%
* Plateau Time: 0.0 to 2.0s
*Inspiratory flow at least 10cmHw to 90cmHw
*ET CO2 ready
*With PSV - TV and APRV modes
Alarm Settings:
* Apnea Interval
* High Circuit Pressure Limit: 7 to 100cm H2O
* High exhaled minute volume: 0.1 to 99.9l or OFF
* High exhaled tidal volume: 50 to 3000ml or Off, 5 to 300ml or
OFF with Neonatal Mode option
* High respiratory rate: 10 to 110/min or OFF
* High inspired mandatory tidal volume
* Low exhaled mandatory tidal volume: 5 to 2500ml or OFF,
1 to 300ml or OFF for neonatal mode
* Low Circuit Pressure Alarm Limit
* O2 Sensor
Monitored (Patient) Data:
* Breath Type
* Delivered O2%
* End Expiratory Pressure
* End Inspiratory Pressure
* Exhaled Minute Volume
* Exhaled Tidal Volume
* I:E Ratio
* Intrinsic PEEP
* Mean Circuit Pressure
* Peak Circuit Pressure
* Plateau Pressure
* Rapid Shallow Index
* Spontaneous Inspiratory Time
* Spontaneous Minute Volume
* Spontaneous Percent Inspiratory Time
* Static Compliance
* Static Resistance
* Total PEEP
* Total Respiratory Rate
Integral Waveforms functons:
* Pressure-time curve
* Flow-time curve
* Volume-time curve
* Pressure-Volume Loop
* Flow-Volume Loop
* All waveforms can be frozen
* Ad...
Closing Date : 2020-06-03

Documents

 Tender Notice


Similar Tenders

Request Demo
GiZ Tenders India

Procurement Documents for Philippines

Access a comprehensive library of standard procurement documents specific to Philippines. Here, you'll find all the essential forms, guidelines, and templates required for tender applications and submissions in Philippines

Explore Procurement Documents for Philippines


Want To Bid in This Tender?

Get Local Agent Support in Philippines and 60 More Countries.

View All The Services


View Tenders By


Publish Tenders


Have Any Dispute With The Purchaser?