Procurement Summary
Country: Philippines
Summary: Procurement of Various Laboratory Equipment - Second Invitation to Bid
Deadline: 06 Aug 2018
Posting Date: 18 Jul 2018
Other Information
Notice Type: Tender
TOT Ref.No.: 25018851
Document Ref. No.: 2018-21-A Second Invitation
Competition: ICB
Financier: Self Financed
Purchaser Ownership: -
Tender Value: Refer Document
CPV Classification
71900000 - Laboratory services
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
Procurement of Various Laboratory Equipment - Second Invitation to Bid
Supply, Delivery and Installation of Various Laboratory Equipment
Items for bidding:
1 unit N, NH4+, NO3-, Phospate AUTOANALYSER (Segmented Flow Autoanalyzer) - Basic SFA system consists of an (1)autosampler (random access autosamplers that are fast, robust and have various rack sizes to meet sample requirements.), (2)a peristaltic pump(Precise, multi-speed peristaltic pumps with electronically controlled air valves to provide precise air bubble injection.), (3)a chemistrymanifold(the chemistry manifold uses close-tolerance glass components, which allow for easy visual check of operation. distillation, dialysis and UV digestion, can also be incorporated.), a (4)detector(high resolution digital photometer, with optimized optics and 24-bit resolution, provides high sensitivity at ultra-low concentrations, wider dynamic ranges and lower detection limits.) and (5)computer and computer data acquisition software(Instrument control and data acquisition is carried out through the intuitive, easy to use AACE software package. AACE is LIMS compatible and both standard and GLP versions are available). The AA3 HR allows for long reaction times as well as the automation of on-line distillation, UV digestion and other complex procedures. Most methods run at 60-70 samples hour. Characteristics: Six analysis modules allowing the simultaneous analysis of nitrites/nitrates, phosphates, ammonium, silicates, total nitrogen and total phosphorous Operation: Average 350 samples/day + 4-10 calibration standards that need to be prepared analytically just before the analysis run ABC- Php. 825, 000.00
1 unit BENCHTOP TURBIDITY, CHLORINE and COLOR METER - Turbidity Unit of Measure: NTU, FNU, AU, FAU, ASBC, EBCRange*: 0 to 4000, 0 to 10, 500 ASBC, 0 to 150 EBC;Resolution*: 0.01 NTU/FNU 0.00 to 10.99, 0.1 NTU/FNU 11.0 to 109.9, 1 NTU/FNU 110 to 4000;
Accuracy*:0 to 2.5 NTU/FNU: A+/-0.05 NTU/FNU;2.5 to 100 NTU/FNU: A+/-2%; Above 100 NTU/FNU: A+/-3%;Detection Limit: 0.05 NTU/FNU;Range Selection: Automatic;
Reproducibility*: 0.02 NTU/FNU, or 1%;
* Over 600 NTU/FNU units expressed as AU/FAU;Light Source: Tungsten (EPA), complie 9 with EPA 180.1, 860 mm LED (ISO), complies with ISO 7027;
ChlorineRange: 0 to 10 ppm; Free and Total Chlorine Resolution:0.00 to 5.00 ppm;Range: 0.01 ppm 5.0 to 10.0 ppm;Range: 0.1 ppm; Accuracy Tablet Ranges:0 to 1.0 ppm: A+/-0.03 ppm;1.0 to 3.0 ppm: A+/-0.06 ppm;
3.0 to 6.0 ppm: A+/-0.3 ppm; 6.0 to 10.0 ppm: A+/-2.5 ppm;Liquid Ranges:0 to 0.5 ppm: A+/-0.03 ppm;0.6 to 3.0 ppm: A+/-0.06 ppm;3.0 to 6.0 ppm: A+/-0.4 ppm;6.0 to 10.0 ppm: A+/-1.5 ppm;Detection Limit: 0.03 ppm;Response Time: 2 seconds;light source:525 nm led, complies with epa 330.5; color range: 0 to 1000 cu;detection limit: 20 cu; accuracy: a+/-15 cu;light source: 428 nm led meter;
Signal Averaging Disabled: 2, 5, 10 min;Power supply AC Adapter Input: 220 VAC 0.3A 60 Hz;Power: USB computer cable, wall adaptor or lithium ion rechargeable battery; (included), 3.7V, 2.5 x 0.75", 1.7 oz;Data Logging: 500 points;Auto Shut-Off Disabled: 5, 10, 30 minutes; Languages: English, French, Spanish, Japanese, Italian, Portuguese, and Chinese;
Response Time: 2 seconds;dimensions: 22.2 w x 19.7 l x 7.6 cm d (8.75 x 7.75 x 3");meter weight: 680 g (1.5 lb);ship weight: 2.72 kg (6 lb);
Include AVR and training on equipment use. ABC - Php. 100, 000.00
1 unit CENTRIFUGE (TABLE TOP HIGH-SPEED) - Max. speed: 30000 rpm; Max RCF: 65395 x g; Max. volume: 6 x 250 ml; Speed range: 200- 30000 rpm with 10 rpm increments; Running time: 59 min 50s/ in 10 s increments 99 h 59 min / I min increments; Temperature range: -20 degrees to 40 degrees Celsius with 1 degree increments; Dimensions: 71.5cm x 42cm x 51cm; Weight: 91kgs; With complete set of (1) rotors (fixed angle rotors: 1 to 30000rpm, swinging bucket rotors: 1 to 25000 rpm), (2) centrifuge tubes and bottles (tubes must be compatible with the rotors, are transparent, translucent, and opaque, tubes that can be sliced or punctured, tubes that can be sterilized and reused, and tubes that are resistant to a variety of chemical compounds) and (3) tools and accessories. Power supply AC Adapter Input: 220 VAC 0.3A 60 Hz
Include AVR and training on equipment use ABC - 495, 000.00
1 unit DOUBLE RING INFILTROMETER - Consist of 3 stainless steel rings with different diameters (for transportation reasons), a hammer, 3 floats, a stainless steel hammering cross, 2 removal hooks and a stopwatch
-c Consist of two cylindrical buckets with the diameter of 30cm and 60cm.
-c Made of durable stainless steel.
-cCross stainless steel tubes in the center to keep steady.
-cEasy to press into soils
-cEasy to operate with perpendicular steel handles
-cNeed to operate with Mariotte tubes
Diameter of inner ring: 30 cm
Volume of inner ring: 3000 ml
Diameter of outer ring: 60 cm
Volume of outer ring: 10000 ml
Height of cylindrical buckets: 50 cm
Material of cylindrical buckets: High-quality stainless steel
Material of Mariotte Tubes: PVC
Power supply AC Adapter Input: 220 VAC 0.3A 60 Hz
a: With Customer Operation Training. ABC- Php. 150, 000.00
1 unit HYDROMETER KIT with SOIL MAGNETIC STIRRER - Set of hydrometers, sedimentation cylinders, thermometer, glass container, heating element with thermostat and stirrer, soil stirrer and other accessories, reading accuracy 1 g/L, Determining particle size distribution of smallest fractions; Power supply AC Adapter Input: 220 VAC, 60 Hz. ABC -Php. 230, 000.00
1 unit NITROGEN and CARBON ANALYZER FOR SOIL AND WATER - Used for the accurate analysis of total nitrogen, total carbon and organic carbon, sulfur.
The main technical indexes of carbon sulfur analyzer: The measuring range: carbon 0.001%-6.00% (Extended); Sulfur 0.003%-2.00% (can be extended); The measurement accuracy: with GB/T223.69-1997, GB/T223.68-1997 standard;The measurement time: 45 seconds;The working voltage: 220V + 10% 50HZ;Main performance characteristics: The gas volumetric method, differential method of liquid carbon absorption, the absorption liquid can be used for a long time, do not need frequent replacement; The amount of iodine statutory sulfur, and the use of high precision photosensor control automatic titration speed, speed, end point constant; The use of imported high-quality wide range sensor, microcomputer and sensor technology, automatic measurement process, measurement results of direct reading display, test report automatic printing; The operation is simple, fast, high accuracy of measurement, the complete elimination of human error, stable and reliable performance. Main technical indicators of intelligent multi element analyzer: Measuring range: wavelength range: 400-780nm; Absorbance range: 0-1.999A; Concentration range: 0-99.99%; Measurement accuracy: in line with GB/T223.3-5-1988 standards; Power supply AC Adapter Input: 220 VAC 0.3A 60 Hz. ABC - Php. 137, 500.00
1 unit PRESSURE PLATE APPARATUS - Contains 15 bar Pressure Plate Extractor; 5 bar Pressure Plate Extractor, 1 bar Pressure Plate; 3 bar Pressure Plates, 5 bar Pressure Plates, 15 bar Pressure Plates (four each), Soil Sample Retaining Rings (4 doz); Manifold for running both extractors; Regulator for 0 to 20 bar (tank to manifold) and a connecting hose; two connecting hose (60" long); PM Hinge; Regulators, 220-240 Volt operated Air Compressor (20 bar) with built-in safety precautions. Complete with all essential installation kit and spare parts; Include AVR and training on equipment use. ABC- Php. 1, 800, 000.00
1 unit VACUUM PUMP - Belt Drive Rotary Vane Dual Stage Mechanical Vacuum Pump heavy duty; Free Air Displacement: up to cfm 30 Li/min., Pump Speed: up to 550 RPM, Oil Capacity: up to 1.2Li, Operating Temperature: 30A F to 170AF, Intake Port: A1/2-3/8- OD for A1/2-3/8- ID Tubing, with adjustable vacuum gas ballast, motor horsepower: 1-1/2 hp, supplied with oil resistant heavy duty tubings and nipple threads; 3 pcs.. Glass T Type Glass Connectors, 220v 60Hz; Include AVR and training on equipment use ABC - Php. 57, 000.00
Line Items
Item No.Product/Service NameDescriptionQuantityUOMBudget (PHP)
1N, NH4+, NO3-, Phospate Autoanalyser(Segmented Flow ABasic SFA system consists of an (1)autosampler (random access autosamplers that are fast, robust and have various rack sizes to meet sample requirements.), (2)a peristaltic pump(Precise, multi-speed peristaltic pumps with electronically controll1Unit825, 000.00
2Benchtop Turbidity, Chlorine and Color MeterTurbidity Unit of Measure: NTU, FNU, AU, FAU, ASBC, EBCRange*: 0 to 4000, 0 to 10, 500 ASBC, 0 to 150 EBC;Resolution*: 0.01 NTU/FNU 0.00 to 10.99, 0.1 NTU/FNU 11.0 to 109.9, 1 NTU/FNU 110 to 4000; Accuracy*:0 to 2.5 NTU/FNU: A+/-0.05 NTU/FNU;2.5 to1Unit100, 000.00
3Centrifuge(Table Top High Speed)Max. speed: 30000 rpm; Max RCF: 65395 x g; Max. volume: 6 x 250 ml; Speed range: 200- 30000 rpm with 10 rpm increments; Running time: 59 min 50s/ in 10 s increments 99 h 59 min / I min increments; Temperature range: -20 degrees to 40 degrees Celsius1Unit495, 000.00
4Double Ring InfiltrometerConsist of 3 stainless steel rings with different diameters (for transportation reasons), a hammer, 3 floats, a stainless steel hammering cross, 2 removal hooks and a stopwatch -c Consist of two cylindrical buckets with the diameter of 30cm and 60cm.1Unit150, 000.00
5Hydrometer kit with Soil Magnetic StirrerSet of hydrometers, sedimentation cylinders, thermometer, glass container, heating element with thermostat and stirrer, soil stirrer and other accessories, reading accuracy 1 g/L, Determining particle size distribution of smallest fractions; Power s1Unit230, 000.00
6Nitrogen and Carbon Analyzer for Soil and WaterUsed for the accurate analysis of total nitrogen, total carbon and organic carbon, sulfur. The main technical indexes of carbon sulfur analyzer: The measuring range: carbon 0.001%-6.00% (Extended); Sulfur 0.003%-2.00% (can be extended); The measurem1Unit137, 500.00
7Pressure Plate ApparatusContains 15 bar Pressure Plate Extractor; 5 bar Pressure Plate Extractor, 1 bar Pressure Plate; 3 bar Pressure Plates, 5 bar Pressure Plates, 15 bar Pressure Plates (four each), Soil Sample Retaining Rings (4 doz); Manifold for running both extracto1Unit1, 800, 000.00
8Vacuum PumpBelt Drive Rotary Vane Dual Stage Mechanical Vacuum Pump heavy duty; Free Air Displacement: up to cfm 30 Li/min., Pump Speed: up to 550 RPM, Oil Capacity: up to 1.2Li, Operating Temperature: 30A F to 170AF, Intake Port: A1/2-3/8- OD for A1/2-3/8- ID Tubin1Unit57, 000.00
Pre-bid Conference
DateTimeVenue
24/07/20182:00 PMAdministration Conference Room 2nd Floor, Admin Building Benguet State University La Trinidad, Benguet
Closing Date : 2018-08-06
Documents
Tender Notice