Procurement Summary
Country: Philippines
Summary: Procurement of Hospital Equipment
Deadline: 23 Dec 2019
Posting Date: 19 Dec 2019
Other Information
Notice Type: Tender
TOT Ref.No.: 39073293
Document Ref. No.: 2019-275(12)amp
Competition: ICB
Financier: Self Financed
Purchaser Ownership: -
Tender Value: Refer Document
CPV Classification
31000000 - Electrical machinery, apparatus, equipment and consumables; lighting
Purchaser's Detail
Name: Login to see tender_details
Address: Login to see tender_details
Email: Login to see tender_details
Login to see detailsTender Details
Procurement of Hospital Equipment
Lot
1.) Two (2) set CARDIAC MONITOR, colored LCD/TFT display at least 12"" (30.48 cm) size, electro-surgical interference suppression/protection, defibrillator Protection, drug dose calculation, freeze and cascade facility, neonatal & pediatric modes of operation, detection, and alarms for all parameters, minimum 9 waveforms, 7 lead ECG waveforms displayed at same time, waveform trace speed: 25 and 50 mm/sec, compatible with central monitoring system through wireless/hardwire, ECG (differential input protected against defibrillator, lead selection: 6 positions (lead I, ii, iii, aVF, aVR, aVL) and v(chest leads), 7 lead ECG waveforms, ability to detect neonatal & pediatric heart rate range, numeric: heart rate, heart rate range: 10-300 bpm, waveform: real time, lead off detection: alarms on lead failure, variable gain: selectable 1/2, 1, 2, cm/mv, heart beat indication: beep/tone with QRS detection), NIBP (oscillometric principle, numeric: systolic, diastolic, and mean pressures, rising cuff/continuous pressure display, cuff pressure range: 300mmHg, selectable auto inflate interval settings),
temperature (numeric: temperature selectable in AC/AF, channels: 2 channels, two temperature channel with probe ( external and rectal)), pulse oximetry (numeric: % oxygen saturation, range: 0-100%, waveform:plethysmograph pulse with pulse strength indication, function of oxy-crg analysis), respiration (impedance method using ECG leads for sensing, respiration rate range: 1-150 bpm, sweep speed: 6.25, 12.5 mm/sec, settable apnea alarm), operating requirements (100-240V, 60Hz autovolts, built-in battery and charger for at least 2 hours on mains supply failure at full parameter), others (must be complete with all sensors, probes, cables or any other accessories required for measuring all the above selected parameters) ( 2967 )
2. One (1) unit EMERGENCY CART at least 470mm x 680mm x 980mm, 250mm cabinet height steel plate body, ABS molded base and top place, pull out writing ( 2993 )
3.) Two (2) set INFUSION PUMP, IV, dual power supply:60Hz / battery rechargeable) automatic Infusio flow rate: capable of 1-1000 ml/h, visible/audible ( 3005 )
for Operating Room, R1MC-Dagupan City, Pangasinan
End-User
Closing Date : 2019-12-23
Documents
Tender Notice