Procurement Summary
Country : Canada
Summary : Power Systems Study - Consulting Services
Deadline : 04 Jul 2025
Other Information
Notice Type : Tender
TOT Ref.No.: 121077816
Document Ref. No. : GOC4622424-CS
Financier : Self Financed
Purchaser Ownership : Public
Tender Value : Refer Document
Purchaser's Detail
Name :Login to see tender_details
Address : Login to see tender_details
Email : Login to see tender_details
Login to see detailsTender Details
Building Name: Elijah Smith BuildingBuilding Address: 300 Main St, Whitehorse, YTConduct a power systems study to protect employees from electrical arcs that may occur during a failure of electrical equipment and improve the coordination of protective equipment. The studies shall include the short circuit study, arc flash analysis and protection coordination in accordance with the regulation CSAZ462 "Workplace Electrical Safety" and IEEE 1584 and with other applicable laws and regulations. Provide and install arc flash labels, verify and update single-wire diagrams for the electrical distribution as part of this scope.Note: Please refer to the Scope of Work (SOW) for a comprehensive description of tasks, project requirements, and deliverables.Electrical installations personnel may be exposed to electrical arcs during their daily tasks. However, there is a need to validate the safety of electrical installations and the protection of the personnel who work there. Electrical arc hazard analyses and studies of short-circuit, application and coordination of protections, as well as the demand for expertise in electrical incidents, are required. Experts should propose and recommend solutions to reduce risk by optimizing protection settings and improving working methods through staff awareness and training. Cyclical Project.
Solicitation Type : RFQ - Request for Quote (Formal)
Reference Number : 0000295967
Location : Canada, Yukon, YT - Yukon
Description : Building Name: Elijah Smith BuildingBuilding Address: 300 Main St, Whitehorse, YTConduct a power systems study to protect employees from electrical arcs that may occur during a failure of electrical equipment and improve the coordination of protective equipment. The studies shall include the short circuit study, arc flash analysis and protection coordination in accordance with the regulation CSAZ462 "Workplace Electrical Safety" and IEEE 1584 and with other applicable laws and regulations. Provide and install arc flash labels, verify and update single-wire diagrams for the electrical distribution as part of this scope.Note: Please refer to the Scope of Work (SOW) for a comprehensive description of tasks, project requirements, and deliverables.Electrical installations personnel may be exposed to electrical arcs during their daily tasks. However, there is a need to validate the safety of electrical installations and the protection of the personnel who work there. Electrical arc hazard analyses and studies of short-circuit, application and coordination of protections, as well as the demand for expertise in electrical incidents, are required. Experts should propose and recommend solutions to reduce risk by optimizing protection settings and improving working methods through staff awareness and training. Cyclical Project.
Documents
Tender Notice