PAO Chiller System. Please see Sources Saught doc and Equipment List attached.
Follow up from initial RFI request (PAO Chiller System (Notice ID: 14816), provide capabilities for the following? The full SOW is also attached for reference.
Provide and install all material to construct overflow basin for PAO chillers and pumps.
Mechanical Room to House PAO Chillers
5.3.1 The Contractor shall construct a dedicated, sound-attenuated room at the designated
location to house the PAO chillers. The room shall meet the following specifications:
5.3.2 Walls: Construct walls using 6-inch, 16-gauge metal studs with 5/8-inch drywall on both
sides. Install R-21 insulation within the framing. Extend walls from the true floor to the
underside of the metal deck above, effectively creating a full-height barrier.
5.3.3 Sound Attenuation: The complete room assembly (walls and doors) must achieve a Sound
Transmission Class (STC) rating of 45.
5.3.4 Doors: Install doors with a minimum STC rating of 45. Provide at least one door of sufficient
size to facilitate the passage of the PAO chillers during installation and maintenance.
5.3.5 Finishes: Paint the walls to match the existing laboratory aesthetic.
5.3.6 Floor and Ceiling Integration: The Contractor shall modify the existing raised access floor and
grid ceiling as necessary to accommodate the new wall placement and chiller skid, ensuring a
seamless and integrated appearance. This modification shall not be done until the
mechanical room is in place and the Chiller skids arrive.
Chiller Support and Containment
5.4.1 The chiller room shall house the support and isolation stand(s) for the PAO chillers.
5.4.2 Each stand shall include a containment pan to meet the contract requirements, unless the
chiller units have integrated containment features.
5.4.3 The new mechanical room layout must accommodate the Pa...
Notice ID: 14816
Department/Ind. Agency: dept of defense
Sub-tier: dept of the air force
Office: fa8222 afsc ol h pzie
Product Service Code: 1660 - aircraft air conditioning, heating, and pressurizing equipment
NAICS Code: 333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
Inactive Dates: feb 24, 2026
Inactive Policy: 15 days after response date
Documents
Tender Notice